Avery Weigh-Tronix PC-905 User Instructions Download Page 27

PC-905 Counting Scale User Instructions

27

4.2   Preset Print Formats

Status Bytes

Summary of Contents for PC-905

Page 1: ...PC 905 Counting Scale PC 905 User Instructions ENGLISH 43002 0016 Issue AB June 2008...

Page 2: ...d States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Page 3: ...ation as a Counting Scale 11 Counting Using a Known Piece Weight 12 Counting Using Bulk Sampling 13 Counting Using Dribble Sampling 14 Using Reverse Sampling for Counting Method 1 15 Using Reverse Sam...

Page 4: ...4 PC 905 Counting Scale User Instructions...

Page 5: ...g methods See the PC 905 Service Manual for details on configuration and calibration This scale also has an RS 232 I O channel for communication with appropriate remote devices The manual is divided i...

Page 6: ...enter a decimal only if a numeric key is pressed first See note at left Use the 0 9 numeric keypad for entering piece weight or tare values There are five keys below the display COUNT WEIGHT Toggles...

Page 7: ...e ZERO Zeroes the scale weight or count The display has seven alphanumeric characters for displaying numbers and messages Annunciators are built into the display to indicate the following functions CO...

Page 8: ...1 Recalling a Piece Weight page 17 3 12 Clearing a Piece Weight page 17 3 13 Recalling a Tare Weight page 17 3 14 Clearing a Tare Weight page 17 3 15 Using the CLEAR Key to Clear Numeric Entries page...

Page 9: ...SAMPLE key on the front panel to turn the scale on Press the SAMPLE key for five seconds to shut the scale off You can set the battery option to shutoff the scale automatically after a period of time...

Page 10: ...the unit will power up when plugged into the outlet or the battery If the unit is in SLEEP standby mode press the SAMPLE key If the display shows SLEEP while powered on AC and not sealed the diagnosti...

Page 11: ...tor is lit numbers on the display show the number of pieces on the scale If the WEIGHT annunciator is lit the display shows the weight of the items on the scale Press the COUNT WEIGHT key to switch be...

Page 12: ...ey followed by a numeric key the 905 knows you meant the first key press as a decimal 1 Press the RCL key then press the numeric keys 0 2 4 7 and 8 then press the PIECE WEIGHT key see note at left The...

Page 13: ...ht of the sample and displays the count If the scale determines that the sample size meets the minimum accuracy requirement 5 will be displayed and you can skip to step 4 If the scale determines the s...

Page 14: ...it for the STABLE annunciator to light and then press the SAMPLE key StAndbY is displayed while the unit computes the weight of the sample and displays the count If the scale determines that the sampl...

Page 15: ...section Method 1 Default setting 1 Place full container on the scale entering an accurate tare weight will allow you to determine the number of parts in the container 2 Press SAMPLE ADD XXX is displa...

Page 16: ...container on the scale and press the TARE key 2 Place the full container on the scale 3 Press the SAMPLE key ADD XXX is displayed 4 Remove the number of parts shown by the ADD XXX prompt The display w...

Page 17: ...r the current piece weight by pressing the CLEAR key and then the PIECE WEIGHT key The scale returns to weight mode Without an active piece weight you cannot switch the scale to count mode 3 13 Recall...

Page 18: ...te scale for counting You can tell which scale is active by the LOCAL and REMOTE annunciators on the display Below is an example of using the BASE key with bulk sampling and auto base switching enable...

Page 19: ...y and 1 stop bit 4 1 Cable Pinouts page 19 4 2 Preset Print Formats page 21 Imp Printer Formats page 21 Dymo Label Writer Setra 300 Formats page 24 Zebra 2844 Printer Formats page 25 PC Protocol page...

Page 20: ...e is digital QDT the connector will be DB 9 female The pinouts for each are shown in the table below DB 9F Scale Serial I O Connector Pin Signal Description 1 Reserved 2 TXD 3 RXD 4 Reserved 5 SIG GND...

Page 21: ...return LF line feed SP space U units character W net weight character C count character T Tare character G gross weight character P piece weight character I weight type identifier G T N gross tare or...

Page 22: ...WWWW WW CR LF 5 Ft 5 Displayed weight with identifier and units In COUNT MODE SP CCCCCCC SP PCS CR LF In WEIGH MODE I SP WWWW WW SP UU CR LF 6 Ft 6 Net weight with units count and piece weight Net WW...

Page 23: ...PC 905 Counting Scale User Instructions 23 4 2 Preset Print Formats 8 Ft 8 Count only with a fixed field format COUNT SP CCCCCCC SP PCS CR LF...

Page 24: ...24 PC 905 Counting Scale User Instructions Serial Communications Dymo Label Writer Setra 300 Formats...

Page 25: ...PC 905 Counting Scale User Instructions 25 4 2 Preset Print Formats Zebra 2844 Printer Formats Time and date will appear only if the printer has this option installed...

Page 26: ...below 5 Value entered is assumed to be in same units of measure as what the scale is currently in 6 Display messages are limited to seven characters COMMAND RESPONSE DESCRIPTION CA CR none Clear Sampl...

Page 27: ...PC 905 Counting Scale User Instructions 27 4 2 Preset Print Formats Status Bytes...

Page 28: ...ifferent depending on selected capacity and division There may not be a decimal point in some gram s unit of measure 2 The character count will be one more if the decimal point is included Command Pos...

Page 29: ...PC 905 Counting Scale User Instructions 29 4 2 Preset Print Formats The NCI protocol may have three status bytes The status bits are defined as follows...

Page 30: ...ions Serial Communications Broadcast Protocol Broadcast protocol will support the use of the RD 4100 RD 6100 and Evolution series indicators as remote displays The broadcast protocol will output this...

Page 31: ...yet been calibrated Lo bAt Low Battery voltage SPL Err Abort Sampling error aborting process Use next available sample size CAn t Unable to perform the requested function CLEAr Press the CLEAR key to...

Page 32: ...5 100 02 01 005 002 001 Capacity kg Available Countby Values 5 000d NTEP Default 25 000d 50 000d 100 000d 5 001 0005 0002 0001 00005 12 002 001 0005 0002 0001 25 005 002 001 0005 0002 50 01 005 002 00...

Page 33: ...30 and 60 minutes for auto shut off and adjustment of backlit to auto or off to increase battery performance Power Supply Standard 120 Vac 10 15 standard 3 wire w ground 60 Hz 3 Hz 9 VDC 1 3 Amps DC...

Page 34: ...34 PC 905 Counting Scale User Instructions Specifications...

Page 35: ......

Page 36: ...USA Tel 507 238 4461 Fax 507 238 4195 Email industrial weigh tronix com www wtxweb com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 0 870 903 4343 Fax 44 0 121 22...