3.10 Using Reverse Sampling for Counting, Method 2
Method 1 or 2 are chosen in the
Service Menu. See the Service
Manual for instructions.
Reverse sampling, method 2, is independent of the bulk or dribble modes. It
does not matter which of those you have enabled.
Reverse sampling occurs when you place an unknown number of items on
the scale, determine a piece weight (by method 1 or 2), and the scale counts
items as they are removed from the scale.
Method 1 and 2 are slightly different. Method 1 results in negative counts as
parts are removed. Method 2 results in positive counts as parts are removed.
Method 2 is explained below, method 1 in the previous section.
Method 2 can be done with or without taring a container. Both ways are
explained below:
Method #2 - With a Tare
Weight
1.
Enter a tare weight by keying in a known tare weight and pressing the
TARE
key, or place an empty container on the scale and press the
TARE
key.
2.
Place the full container on the scale.
3.
Press the
SAMPLE
key. . .
ADD XXX
is displayed.
4.
Remove the number of parts shown by the
ADD XXX
prompt. . .
The display will flash
ADD XXX
.
5.
Press the
SAMPLE
key. . .
The display will show the number of parts remaining in the
container.
6.
Place the parts that were sampled back into the container. . .
The total number of parts is displayed.
7.
If you want to see positive counts as items are removed from the
scale, press the
ZERO
key. . .
The scale will clear the count and tare value and as parts are
removed from the scale, the display will show a positive number.
Method #2 - Without a Tare
Weight
1.
Without a tare weight entered place full container on the scale.
2.
Press the
SAMPLE
key. . .
ADD XXX
is displayed.
3.
Remove the number of parts shown by the
ADD XXX
prompt. . .
The display will flash
ADD XXX
.
4.
Press the
SAMPLE
key. . .
The display will show the number of parts removed from the scale.
5.
Keep removing parts to see the total number removed.
6.
You can add more parts to the scale, then press the
ZERO
key to zero
the count and continue removing parts and counting what you
remove.
Summary of Contents for PC-905
Page 1: ...PC 905 Counting Scale PC 905 User Instructions ENGLISH 43002 0016 Issue AB June 2008...
Page 4: ...4 PC 905 Counting Scale User Instructions...
Page 27: ...PC 905 Counting Scale User Instructions 27 4 2 Preset Print Formats Status Bytes...
Page 34: ...34 PC 905 Counting Scale User Instructions Specifications...
Page 35: ......