![Avery Dennison ALS 350 User Manual Download Page 85](http://html1.mh-extra.com/html/avery-dennison/als-350/als-350_user-manual_3030413085.webp)
85
4
O
PERATION
4.6 A
PPLICATOR
(
OPTIONAL
)
ALS
350
450
Fine tuning of the dwell time
(APT4)
When using an applicator in combination with the auto-
matic speed adjustment (APSF):
– Optimise the accuracy of the label position on the
product by fine tuning the dwell time for the applica-
tor.
Standard values:
– Blowing applicators: approx. 25 ms
– EP applicators: 60 ms ... 100 ms, depending on the
length of the stroke
Prerequisite:
– External RPM transmitter is calibrated (EGRA func-
tion)
Determining and setting the exact value [88]:
£
Call up the APT4 function in the extended menu.
£
Set the setting value for APT4 to 1.
£
Allow the conveyor belt (with products) to run slowly.
– Speed
v
N
= 10 m/min
£
Document the position of the label on the product:
Value:
POS
N
in mm
£
Increase speed of the conveyor belt to approx.
25 m/min (value
v
H
).
£
Document the position of the label on the product:
Value:
POS
H
in mm
£
Calculating the setting value for APT4:
£
Input the calculated setting value.
£
Confirm the value using the ENTER key and exit the
function.
Test the setting:
£
Test the labelling accuracy at different conveyor belt
speeds.
£
If necessary, correct the setting value for APT4:
– The greater the value for APT4, the farther forward
the label is applied.
– The smaller the value for APT4, the farther to the
rear the label is applied.
[88] Label position in relation to the conveyor belt speed
v
N
- Low conveyor belt speed
POS
N
- Label position at lower conveyor belt speed
v
H
- High conveyor belt speed
POS
N
- Label position at higher conveyor belt speed