FXT 5000 Series Installation Guide
7.2.3 Front Panel: Unit Identifier LED
LED Name
State
Meaning
Action (if applicable)
Unit Identification (UID)
LED
(within the UID button)
Unlit
Normal state (unit identification has
not been activated)
N/A
Solid blue
Local UID has been activated by
pressing the UID button on the front
panel
Push the UID button
again to turn off the light
Blinking blue
Remote UID has been activated from
the IPMI remote web interface
Turn off the LED by
deactivating remote UID
in the IPMI web interface
7.2.4 Rear Panel: Power Supply LEDs
LED Name
State
Meaning
Action (if applicable)
Power Supply
LEDs (PS1,
PS2)
Unlit
Neither power supply is
receiving AC power
Check that each power supply is fully
seated, has a power cord installed, and is
connected to AC power. Reseat each power
supply, install cords, and/or apply power as
required.
Solid green
Power is being supplied and the
unit is powered on
N/A
Blinking
green
Power is being supplied but the
unit is powered off
To power on the system, press the power
button on the front of the node.
Solid yellow
This power supply is not
receiving AC power, but the
other power supply is receiving
power
Check that the power supply is fully seated,
has a power cord installed, and that AC
power is being applied. Reseat the power
supply, install a cord, and/or apply power
as required.
Blinking
yellow
Overheat warning: The power
supply internal temperature has
reached at least 63° C (145.4°
F).
If the power supply temperature
reaches 70° C (158° F), the
system will automatically
power down. It will restart
when the power supply
temperature falls below 60 °C
(140° F).
Check the ambient room temperature and
improve cooling if needed.
7.2. Status LEDs