LEDs for the FXT 2x50, 3xx0, and 4xx0 Series
33
7.3. LEDs for the FXT 2x50, 3xx0, and 4xx0 Series
This section describes the meanings of the LEDs on the FXT 2x50 Series, FXT 3xx0 Series, and FXT 4xx0
Series nodes. See Section 2.3, “FXT 2x00 Series Nodes: Front and Rear Illustrations” on page 5 for the
locations of LEDs.
FXT 2x50, FXT 3xx0, and FXT 4xx0 Series LEDs
LED name
State
Meaning
Action (if applicable)
Front Panel
Green
Power is being supplied to the
node’s power supply units.
N/A
Power LED
Unlit
Power is not being supplied to
the node’s power supply units.
To power on the system, press
the Power button.
Drive activity LED
Blinking amber
• Activity on one or more
data drives in slots 0 - 7.
(All FXT Series)
• Activity on slot 15 (system
drive) (FXT 2x50 Series
only)
N/A
NIC1 LED
Blinking green
Ethernet port e0a is active.
N/A
NIC2 LED
Blinking green
Ethernet port e0b is active.
N/A
Unlit
Cooling system is working
properly.
N/A
Blinking red, once per
second
Fan failure.
Check for a failed fan. If
needed, replace it as described
in Chapter 6, Replacing a
Fan of the FXT Series Field
Service Guide.
Blinking red, once
every four seconds
(not on FXT 2x50
series)
Power failure.
Check for a failed power
supply unit. If needed, replace
it as described in Chapter 4,
Replacing Power Supply
Units of the FXT Series Field
Service Guide.
Solid red
System temperature is too
high.
Check ambient room
temperature and correct if too
high. Otherwise, contact Avere
Global Services for assistance.
Solid blue (not on
FXT 2x50 series)
UID has been activated
locally.
Use this LED to locate
the server in a rack mount
environment.
Informational LED
(Overheat/fan fail LED
on FXT 2x50 series)
Blinking blue (not on
FXT 2x50 series)
UID has been activated from a
remote location.
Use this LED to locate
the server in a rack mount
environment.
FXT 2x50, FXT 3xx0, and FXT 4xx0 Series LEDs
LED name
State
Meaning
Action (if applicable)
Power fail LED
Unlit
Both power supply units are
working correctly.
N/A