32
LEDs for the FXT 2x00 Series
FXT 2x00 Series LEDs
LED name
State
Meaning
Action (if applicable)
Blinking green Drive is being accessed.
N/A
Data drive, upper LED
Solid green
Disk is initializing and has a
pending access request.
Contact Avere Global Services
if the drive does not start
normal activity, indicated by
a blinking LED, after several
minutes.
Data drive, lower LED
Red
Drive failure.
Check for a failed drive. If
needed, replace it as described
in Chapter 5, Replacing
Drives of the FXT Series Field
Service Guide.
Rear Panel
Green
The FXT Series node is
powered on and the power
supply unit is operating
normally.
N/A
Amber
Power is being supplied to the
power supply unit but the FXT
Series node is powered off.
To power on the system, press
the Power button.
Power Supply Unit LED
Unlit
Power is not being supplied to
the power supply unit.
Attach power cords and verify
that power is available from
the power source.
IPMI lower LED
Green
IPMI port is connected.
N/A
IPMI (100MbE e7a) upper
LED
Blinking
amber
Activity on IPMI port.
N/A
1GbE e0a or e0b left-hand
LED
Amber
Port is connected.
N/A
1GbE e0a or e0b right-hand
LED
Blinking green Activity on port.
N/A
10GbE upper LED
Blinking green Activity on port e1a
N/A
10GbE lower LED
Blinking green Activity on port e1b
N/A
1GbE e2a-e2d/e3a-e3d lower
LED
Amber
Port is connected.
N/A
1GbE e2a-e2d/e3a-e3d right-
hand LED
Blinking green Activity on port.
N/A