background image

www.avenview.com 

 

Problem

 

Possible Solution

 

Power ON 

Power LED does not 
work 

 

Please check out voltage of adapter. (DC +5V) 

 

Ensure that power adapter correctly plugged 

Cannot read selected 

EDID 

 

Select switch the emulation mode 

-

 

Retry self EDID read   

-

 

Check the monitor to read EDID 

 

Select switch the real mode. 

-

 

Please check and connected the UTP cable. (Only the direct 
type)   

-

 

Please check if the DVI cable is connected. 

Resolution Issue 

 

Select single mode switch 

-

 

Max resolution 1920x1200@60Hz 

-

 

Some monitor will not support this mode. 

 

Select dual mode switch 

-

 

Max resolution 2560x1600@60Hz 

-

 

Please check and connect    DVI cable type (Should use DVI-Dual 
cable) 

 

Noise or no display 

-

 

Please check the DVI and optical fiber cable is connected. 

 
*** The max resolution is different on to connected monitor 

 

 

 

 

Self EDID Setting :   

 

1) DDC function switch set to Emulation.

 

2) DVI cable connection between TX and display.

 

3) Supply power to TX (DC +5[V]).

 

4) LED blink -> LED ON

 

 

Summary of Contents for FO-DVI-DL-330X

Page 1: ...descriptions at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth in Avenview Standard Ter...

Page 2: ...latory Notices Federal Communications Commission FCC 4 1 4 Introduction 4 1 5 Package Contents 5 1 6 Before Installation 5 1 7 Panel Description 6 1 8 Installation 7 1 9 Function Switch 7 1 10 General...

Page 3: ...structions The Avenview FO DVI DL 330X DVI Dual Link Extender over Fiber Optic has been tested for conformance to safety regulations and requirements and has been certified for international use Howev...

Page 4: ...this equipment 1 4 Introduction Avenview FO DVI DL 330X Series with fiber optic cable system lets you extend dual link digital signal up to 100m 330 feet High Speed and long distance transmission Use...

Page 5: ...roduct in an even and stable location If the product falls down or drops it may cause an injury or malfunction Don t place the product in too high temperature over 50 C too low temperature under 0 C o...

Page 6: ...avenview com 6 1 7 Panel Description REAR PANEL Receiver FO DVI DL 330X UTP port for DDC DVI Input port Power jack Optical 2ch L C port UTP port for DDC DVI Output po rt Power jack Optical 2ch L C po...

Page 7: ...onnect 2 Strand Fiber Optic LC Type cable to both Transmitter and Receiver 4 Plug the power to Receiver Unit 5 Power on DVI Source and DVI Display 1 9 Function Switch EDID Switch in front of Transmitt...

Page 8: ...www avenview com 8 1 10 General Troubleshooting...

Page 9: ...pe Please check if the DVI cable is connected Resolution Issue Select single mode switch Max resolution 1920x1200 60Hz Some monitor will not support this mode Select dual mode switch Max resolution 25...

Page 10: ...stance Single Link WUXGA 1920 x 1200 100 meters 330 feet Dual Link WQXGA 2560 x 1600 100 meters 330 feet Optical Converter 2 ch 850 nm Multi Mode VCSEL 2 ch GaAs PIN photo Diode DVI Connector 24 pin D...

Page 11: ...ower 22 T M D S Clock Shield 7 DDC Data SDA 15 Ground for 5V 23 T M D S Clock 8 No Connect 16 Hot Plug Detect 24 T M D S Clock RECEIVER Pin Signal Assignment Pin Signal Assignment Pin Signal Assignmen...

Page 12: ...5V Power 22 T M D S Clock Shield 7 DDC Data SDA 15 Ground for 5V 23 T M D S Clock 8 No Connect 16 Hot Plug Detect 24 T M D S Clock RECEIVER Pin Signal Assignment Pin Signal Assignment Pin Signal Assig...

Page 13: ...atory profits or for punitive incidental or consequential damages in connection with the furnishing performance or use of the Avenview hardware software or other products and documentation provided he...

Reviews: