AVENTICS
| ES05 | R415017129–BAL–001–AA
29
Test preparation
English
5
Test preparation
Make the following basic settings to ensure ready state:
1.
Close the ball valve (1) on the control module.
2.
Connect the output of the control module with the input on the valve system (red tubing, fig. 1,
2
).
3.
Plug the pressure indicators into outputs 2 and 4 on the valve system.
4.
Establish the electrical connection between the switch box (Fig. 1,
12
) and the valve system.
(Multipole connection cable or connection cable form C, industry)
5.
Switch the compressed air on.
6.
The compressed air is pre-set to 6.3 bar. Adjust it as required.
7.
Open the ball valve (1) (Fig. 11).
CAUTION
System is under high pressure
Incorrect or incomplete connections can result in uncontrolled pressure drops during
commissioning. Components being hurled away can cause damage to eyes.
O
Wear safety glasses for the entire test process.
Fig. 9:
Connect the ball valve (1)
Fig. 10: Pressure indicator
1
Ball valve (1)
2
Ball valve (2)
Fig. 11: State for valve system filling: ball valve 1 open, ball valve 2 closed
2
1
Summary of Contents for ES05
Page 2: ......
Page 3: ...Betriebsanleitung R415017129 06 2016 Ersetzt DE Essential Test Box ES05 Deutsch ...
Page 18: ...18 AVENTICS ES05 R415017129 BAL 001 AA Ersatzteile ...
Page 19: ...Operating Manual R415017129 06 2016 Replaces EN Essential Test Box ES05 English ...
Page 34: ...34 AVENTICS ES05 R415017129 BAL 001 AA Spare parts ...
Page 35: ...Mode d emploi R415017129 06 2016 Remplace par FR Essential Test Box ES05 Français ...
Page 50: ...50 AVENTICS ES05 R415017129 BAL 001 AA Pièces de rechange ...
Page 51: ...Istruzioni per l uso R415017129 06 2016 Sostituito IT Essential Test Box ES05 Italiano ...
Page 66: ...66 AVENTICS ES05 R415017129 BAL 001 AA Parti di ricambio ...
Page 67: ...Instrucciones de servicio R415017129 06 2016 Sustituye ES Essential Test Box ES05 Español ...
Page 82: ...82 AVENTICS ES05 R415017129 BAL 001 AA Piezas de repuesto ...
Page 83: ...㝜 広㢝 R415017129 06 2016 㦎㗱 ದ Essential Test Box ES05 㠖 ...
Page 91: ... 9 17 6 _ 6 _ 5 ದ ದ ದ 㘹㡌 㠖 䞷 捷㘶Ⓟ䴉㺣 全孔函 㨐㙡 㿚幤梏 W 抩扖㘴 ㄣ㘶Ⓟ䴉㺣ᇭ W 㘴 權め 桼ᇭ ...
Page 96: ... 9 17 6 _ 6 _ 5 ದ ದ ದ ↅ ↅ 喀Ⓟ LQFK 5 㘴 丰 喀Ⓟ LQFK 5 㖖䯉 㖖䯉 嫷婉㡚㘴 懻䩸婉 5 啀枽 7 5 0 䟄冕 ぴ 5 ...
Page 97: ...Bruksanvisning R415017129 06 2016 Ersätter SV Essential Test Box ES05 Svenska ...
Page 112: ...112 AVENTICS ES05 R415017129 BAL 001 AA Reservdelar ...