![AVE AF902R-CE Manual Download Page 42](http://html1.mh-extra.com/html/ave/af902r-ce/af902r-ce_manual_3028666042.webp)
- 40 -
G
Function 7: storing or modification of radio codes CODE 1 ÷ CODE 4.
The dialler can store the signals coming from the following transmitting devices:
• AF53994R and AF909RS control panels
• AF938R remote control
• AF939R remote control
• AF968R, AF913R and AF913R-M detectors.
As soon as the dialler receives the code transmitted by one of the above-mentioned devices
duly stored as below, it enables the related alarm cycle.
8 codes can be stored, 4 ones for each channel (also of different types).
Codes 1, 2, 3, 4 enable channel 1 whereas codes 5, 6, 7, 8 enable channel 2.
Jumper JP1 must be on the INST position to enter this function.
A) First storing of the radio code
FUNZIONI
FUNZIONI
Programming of FUNCTIONS
FUNCTION 7 entering:
programming of CODE 1 ÷ CODE 4
COD mes 1
COD mes 1
7
1
✗
CODE 1 programming entering.
To perform the programming of next codes,
just set the related progressive number
Execute the programming mode of the invol-
ved transmitting device.
(see note 6).
Confirmation of storing of CODE 1 with musi-
cal input. (3 sec.)
C O D 1
C O D 1
C O D 1 O K
C O D 1 O K
✗
Exit from programming
2
4
÷
1
C.415 10-06-2002 9:11 Pagina 40