22
Fault Diagnosis
Symptom
Possible Cause
Remedy
Page Ref
Item numbers in
bold
refer to the general assembly drawing and parts list on pages 18-19.
More than one
Air leak
Tighten joints or replace components
operation of the
Insufficient air pressure
Adjust air pressure to within specification
5
trigger needed to
Lack of lubrication
Lubricate tool at air inlet point
7 & 13
place fastener
Worn or broken jaws
Fit new jaws
8-11
Low oil level or air in oil
Prime tool
20-21
Build up of dirt inside the nose assembly
Service
11
Tool will not grip
Worn or broken jaws
Fit new jaws
8-11
stem of fastener
Build up of dirt inside the nose assembly
Service
11
Loose jaw housing or chuck collet
Tighten against locking ring
9-11
Weak or broken spring in nose assembly
Fit new spring
8-11
Incorrect component in nose assembly
Identify and replace
8-11
Rotary valve incorrectly adjusted
Read ‘Operating Procedure’
7
Jaws will not release Build up of dirt inside the nose assembly
Service
11
broken stem of
Jaw housing or chuck collet, nose tip and
fastener
nose casing not properly seated
Tighten nose assembly
9-11
Weak or broken spring in nose assembly
Fit new spring
8-11
Air or oil leak
Tighten joints or replace components
Low oil level or air present in oil
Prime tool
20-21
Cannot feed next
Broken stems jammed inside tool
Empty stem collector
4 (point 14)
fastener
Check jaw spreader is correct
8-11
Adjust air pressure to within specification
5
Rotary valve incorrectly adjusted
Adjust following ‘Operating Procedure’
7
Slow cycle
Lack of lubrication
Lubricate tool at air inlet point
7 & 13
Low air pressure
Adjust air pressure to within the specification 5
Build up of dirt inside the nose assembly
Service
11
Tool fails to operate
No air pressure
Connect and adjust to within the specification 5
Damaged trigger valve
42
Replace
16
Loose base cover
35
Tighten
16
Loose stem collector
Tighten retaining nut
22
16
Fastener fails to break Insufficient air pressure
Adjust air pressure to within specification 5
Fastener outside tool capability
Use more powerful Genesis tool.
Contact Avdel
Low oil level or air present in oil
Prime tool
20-21
Incorrect length of fastener (Maxlok
®
ONLY) Change to correct length
Tool fails to swage
Insufficient air pressure
Adjust air pressure to within specification
5
collar (Maxlok
®
ONLY) Worn or damaged anvil
Replace
10-11
Low oil level or air present in oil
Prime tool
20-21
Incorrect length of fastener
Change to correct length
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.