Frame relay encapsulation
Issue 1 January 2008
421
Related Commands
,
,
,
frame-relay priority-dlci-group
,
,
frame-relay lmi-n393dte
Use the
frame-relay lmi-n393dte
command to set the number of status polling intervals
over which the error threshold is counted (the monitored event count). To set the error
threshold, refer to
on page 420. In other words, if within
events
number of events the station receives
error_threshold
number of errors, the interface is
marked as down.
Use the
no
form of this command to revert to the default value.
Syntax
[no] frame-relay lmi-n393dte
events
Parameters
User Level
read-write
Context
interface:Serial (DS1 FR L2, USP FR L2)
Example
To set the number of events over which the error threshold is calculated to 5:
G450-001(if:Serial 3/1:1)# frame-relay lmi-n393dte 5
Parameter
Description
Possible
Values
Default
Value
events
The number of events
1-10
4