Additional Processes: Using the External Output Port
5.9 Reset Button
The IP500 and IP500 V2 control units have a Reset button. Pressing the button while the control unit is starting up will
pause the start up until the button is released. The effect of pressing the button during normal operation will depend on
how long the button is pressed and is indicated by the CPU LED.
Press Duration
(seconds)
CPU LED
Action
Summary
0 to 5.
Off
None
None.
5 to 10.
Orange
Reboot When Free
Reboot when free with new incoming/outgoing call
barring. A reboot using the reset button is recorded in
the Audit Trail.
10 to 30.
Flashing orange Erase Configuration/
Immediate Reboot
Erase the configuration, alarm log and audit trail.
Immediate reboot without waiting for active calls to end.
30 to 40.
Red
Erase All.
Erase configuration, alarm log and core software.
Over 40.
Flashing green
None
None.
5.10 AUX Button
IP500 V2 control units have an AUX button. This button can be used as follows.
If pressed during a restart of the control unit, the control unit
skip booting
from the /primary folder on the System SD
card.
If pressed for between 5 and 10 seconds when a system is running, the control unit will shutdown for 10 minutes.