AVANTI Service Lift for Wind Turbines
After installation:
An inspection must be carried out by a competent
person following the inspection form in this manual.
Before use:
Each time using the AVANTI LIFT ANCHOR the
user inspects the ANCHOR visual and manually by
twisting / pulling. Check the parts are properly fixed
and free of deformities, damages, cracks or similar
unacceptable defects.
Periodical examination:
A periodic examination at least
every 12 month is essential for the safety of the
AVANTI LIFT ANCHOR. The examination must be
performed by a competent person following the
inspection form in this manual.
For the AVANTI LIFT ANCHOR the competent
person (authorized in writing by AVANTI) only needs
to be trained in any metallic component covered
by the European/American standard norms for fall
arrest equipment.
PPE Anchor:
Manufacturer:
Avanti
Type / Model:
Lift Anchor
Identification no.:
Fixing structure:
Lift serial no.:
Lift model:
Wind farm / WTG no.:
Installed by:
Installation company:
OK
not OK
1. Lift structure does not show any deterioration.
2. Anchor locking screws are fully inserted and tightened with 15 N·m.
3. Anchor does not show cracks, deformities, corrosion or other damages.
4. Anchor installed on the lift structure according to the instructions.
5. Anchor marking is clearly readable.
C.6 Inspection form
C.5 Inspection
If the AVANTI LIFT ANCHOR is found not OK, it must be removed / replaced by a new AVANTI LIFT ANCHOR!
The result of the periodic examination must be recorded in the Registration form of anchor.
Signature of competent:
Name of competent in
capital letters:
Date:
Is the Anchor in good condition to be used?
Yes No (Replace)