LEVELING
All four casters of your unit must rest firmly on a solid floor. Use adjustable wrench to adjust leveling screws.
REGULATOR INSTALLATION
• Check to ensure plastic washer is inside the hex nut.
• Fasten the CO2 regulator (6) to the CO2 canister (12). Place the regulator to
the right of the tank.
• Tighten the hex nut securely. DO NOT over tighten. Over-tightening may
damage the gasket in the nut of the regulator.
SMALL CO2 HOSE TO REGULATOR CONNECTION
• Attach wing nut on end of small hose (8) to fitting at bottom of regulator (6).
SMALL CO2 HOSE TO COUPLER CONNECTION
• Secure other end of small hose (8) to the threaded end of keg coupler (7) as shown. Be
sure to fully tighten fitting.
NOTE: Depending on your choice of beer, you may require a different keg coupler (7) .
Check with your local beer distributor to determine which type of system you need,
and order additional keg couplers as needed .
COUPLER TO KEG CONNECTION
• Align locks on keg coupler (7) with housing on top of keg and push down on the keg
coupler (7). Make sure top handle is in the up position.
• Turn the tap head handle clockwise 1/4 turn. The tap head is now secured to the keg.
• Pull the tap handle out and push down until it locks into place to open the port in the keg.
DELIVERY HOSE PRESSURIZATION
• Open the CO2 canister valve all the way by turning counterclockwise until it stops. This
valve seals at both the fully open and fully closed positions.
Failure to completely open or close the valve could result in premature loss of CO2
pressure.
• Open the regulator shut-off valve by moving it to the 6 o’clock position.
• Check gauge pressure. Adjust the regulator adjustment knob Knob as necessary until
the pressure reads between 12 to 14 psi. You may first need to loosen set screw located
behind knob. After setting regulator to correct pressure, set screw may be retightened to
lock knob in place.
CLEAR HOSE TO COUPLER CONNECTION
Place one of the supplied rubber washers inside the wing nut on the one end of the clear
hose (beverage delivery line) and attach to keg coupler
(7). Be sure to tighten the nut securely to prevent leakage. DO NOT overtighten.
Overtightening may damage the gasket in the nut.
CAUTION: do not attempt to move or relocate the keg cooler with a keg inside .