background image

C43 and C47 Series

  

1" – 2” Water Softeners and Conditioners

OWNER’S MANUAL

Summary of Contents for C43 Series

Page 1: ...C43 and C47 Series 1 2 Water Softeners and Conditioners OWNER S MANUAL ...

Page 2: ...ers are precision built high quality products These units will deliver conditioned water for many years to come when installed and operated properly Please study this manual carefully and understand the cautions and notes This manual should be left at the installation site by the servicing agent to use as future reference by the system owner If you have any questions regarding your water condition...

Page 3: ...T Confirm installer programming settings are correct Read Operating Displays and Maintenance section Set the time of day Read Power Loss and Error Display section Ensure that system and installation are in compliance with all state and local laws and regulations The manufacturer has preset the water treatment unit s sequence of cycles cycle times salt dose exchange capacity and salt dose refill ti...

Page 4: ...DAY will flash alternately if a regeneration is expected tonight NORMAL OPERATION BYPASS OPERATION ERROR 106 CALL FOR SERVICE GENERAL OPERATION When the system is operating one of six displays will be shown Pressing will toggle between the six choices 1 Time of day gpm 2 Flow rate 3 Vacation mode 4 Capacity remaining 5 Days to a regen 6 Dealer name and phone number TO SET TIME OF DAY In the event ...

Page 5: ...ance to the next screen ALARM BUZZER START SET 6 00 AM ALARM BUZZER END SET 8 00 PM SERVICE ALARM SET OFF REGEN TIME MINUTES SET 2 00 AM REGEN TIME HOUR SET 2 00 AM DAYS BETWEEN REGEN SET 10 WATER HARDNESS SET 20GR LIGHT NORMALLY SET ON SERVICE ALARM SET OFF GAL YR TIME OF DAY MON PM GPM 2 40 8 QUICK REFERENCE GUIDE 1 1 25 SINGLE 1 5 2 0 SINGLE 1 5 2 0 TWIN 1 1 25 TWIN ALT TYPICAL INSTALLATION CON...

Page 6: ...l operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated water to the distribution system Fig 1 2 BYPASS POSITION The inlet and outlet handles point to the center of the bypass The system is isolated from the water pressure in the plumbing system Untreated water is supplied to the building Fig 2 3 D...

Page 7: ...e value represents the maximum number of days between regenerations If any number is set 1 28 days a regeneration will be scheduled for that day if the gallon capacity has not been met If OFF is set the unit will only initiate a regeneration once the gallon capacity has been met STEP 4 REGENERATION HOUR Use the or buttons to adjust the time of day the unit will regenerate AM PM toggles after 12 Th...

Page 8: ...r the alarm BUZZER START TIME Press the or buttons to select the hour when the buzzer should begin sounding AM PM toggles after 12 Default setting is 6 00 a m BUZZER STOP TIME Press the or buttons to select the hour when the buzzer should stop sounding AM PM toggles after 12 Default setting is 10 00 p m STEP 9 BACKLIGHT DISPLAY CONTROL Use the or buttons to turn the backlight setting ON or OFF If ...

Page 9: ... Any changes made prior to the exit will be incorporated If no buttons are pressed within five minutes the display will return to the general operating displays 4 REGENERATION AND STANDBY DISPLAY Typically a system is set to regenerate at a time of no water usage If there is a demand for water when the system is regenerating untreated water will be delivered When the system begins to regenerate th...

Page 10: ...e was not able to function properly 8 BRINE TANK MAINTENANCE AND SALT Refill the brine tank as necessary making sure at least 1 3 of the brine tank is full at all times Without proper salt levels the water softener may not operate properly Because typical settings of this water softener include a dry salt storage feature no water in brine tank between regeneration the manufacturer recommends the u...

Page 11: ... 6 Control valve does not regenerate automatically when the correct button s is depressed and held For timeclock valves the buttons are For all other valves the button is REGEN A Broken drive gear or drive cap assembly B Broken piston rod C Defective PC board D Cover installed incorrectly 7 Control valve does not regenerate automatically but does when the correct button s is depressed and held For...

Page 12: ...eing delivered to PC board 16 E3 Err 1003 Err 103 Control valve motor ran too long and was unable to find the next cycle position A Motor failure during a regeneration B Foreign matter built up on piston and stack assemblies creating friction and drag enough to time out motor C Drive bracket not snapped in properly and out enough that reduction gears and drive gear do not interface 17 E4 Err 1004 ...

Page 13: ...regeneration cycle step detected 22 Err 204 Leak detected A Occurs when dP input is active for ALARM and the input is closed The alarm buzzer will activate and the screen will display the error 23 Err 400 Memory Errors All 400 errors pertain to memory related errors A Depleted Battery B Defective PC Board ...

Page 14: ...2WE PC board used on chlorine generator models 1 CV4022WU PC board standard 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 not shown CV3526 Transformer 110V 15V DC used on chlorine generator models 1 CV3186 Transformer 110V 12V AC standard 1 CV3543 Optional weather cover 1 CV4276 15 36 System controller power cord 1 REPLACEMENT PARTS NOTE Battery Location 2 1 3 5 4 6 ...

Page 15: ... piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HEX 18 8SS 1 10 CV3016 QC2 clamp assembly includes screw nut 1 11 CV3452 O ring 230 1 12 CV3015 WS1 QC2 tank adapter assembly includes O rings 1 13 CV3001 04 1 body assembly downflow 1 CV3020 1 25 body assembly downflow 1 14 CV3541 Driv...

Page 16: ... Qty 1 CV3004 Drive Cap Assembly 1 2 CV3135 O Ring 228 1 3 CV3407 1 5 Piston Downflow 1 4 CV3174 Regenerant Piston 1 5 CV3423 1 5 Backplate Dowel 1 6 CV3430 1 5 Spacer Stack Assembly 1 7 CV3541 Drive Back Plate 1 8 CV3419 O Ring 347 1 9 CV3418 O Ring 328 1 10 CV3400 01 1 5 Valve Body Downflow 1 ...

Page 17: ... 230 1 4 CV3728 Ws2 Drive Cap Assembly 1 5 CV3724 Washer Flat SS 1 4 1 6 CV3642 Bolt BHCS S S 1 4 20 X 1 25 1 7 CV3541 Drive Back Plate 1 8 CV3729 WS2 Stack Assembly 1 9 CV3419 O Ring 347 for WS15 1 10 CV3641 O Ring 225 for bodies with NPT threads 1 11 CV3700 01 WS2 Body NPT 1 NOT SHOWN CV3468 WS2H Plug 1 4 Hex NPT 1 CD1300 Top Baffle DFSR Clack 1 5 50mm 1 9 2 5 8 1 ...

Page 18: ...k Only available on 1 and 1 25 valves on 16 or smaller tanks 1 BYPASS VALVE Item No Part No Description Qty 1 CV3006 Bypass assembly 1 2 CV3147 Bypass handles 2 Loosens Injector And Bypass Caps Loosens Drive Cap Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in various positions on the valve is available to aid in assembly or disassembly SERVICE WRENC...

Page 19: ... 1 3 CV3968 WS1 5 Injector Feed Tube Dnflw BLK 1 CV3968 01 WS1 5 Injector Feed Tube Upflw Gray 1 4 CV3177 01 WS1 Injector Screen 1 5 CV3969 WS1 5 Injector Draw Tube Dnflw Black 1 CV3969 01 WS1 5 Injector Draw Tube Upflw Gray 6 CV3176 WS1 Injector Cap 1 7 CV3152 O Ring 135 1 8 CV3010 15B WS1 5 Injector Assembly B 1 CV3010 15C WS1 5 Injector Assembly C 1 CV3010 15D WS1 5 Injector Assembly D 1 CV3010...

Page 20: ...3010 15F 1 CV3010 2W 15G WS2 2H INJ W Assembly W CV3010 15G 1 CV3010 2X 15H WS2 2H INJ X Assembly W CV3010 15H 1 CV3010 2A WS2 2H Injector Assembly A 1 CV3010 2B WS2 2H Injector Assembly B 1 CV3010 2C WS2 2H Injector Assembly C 1 CV3010 2D WS2 2H Injector Assembly D 1 CV3010 2E WS2 2H Injector Assembly E 1 CV3010 2F WS2 2H Injector Assembly F 1 CV3010 2G WS2 2H Injector Assembly G 1 5 CV3731 WS2 I...

Page 21: ...in 1 Strt No Sil 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elbow locking clip 1 2 CPKP10TS8 BULK Optional insert 5 8 tube 1 3 CV3192 Optional nut 3 4 drain elbow 1 4 CV3158 02 Drain elbow 3 4 NPT with O ring 1 5 CV3163 O ring 019 1 6 CV3159 01 DLFC retainer assembly 1 7 CV3162 0...

Page 22: ...22 WS1 DLFC 2 2 GPM FOR 3 4 1 CV3162 027 WS1 DLFC 2 7 GPM FOR 3 4 1 CV3162 032 WS1 DLFC 3 2 GPM FOR 3 4 1 CV3162 042 WS1 DLFC 4 2 GPM FOR 3 4 1 CV3162 053 WS1 DLFC 5 3 GPM FOR 3 4 1 CV3162 065 WS1 DLFC 6 5 GPM FOR 3 4 1 CV3162 075 WS1 DLFC 7 5 GPM FOR 3 4 1 CV3162 090 WS1 DLFC 9 0 GPM FOR 3 4 1 CV3162 100 WS1 DLFC 10 0 GPM FOR 3 4 1 CV3190 090 WS1 DLFC 9 0 GPM FOR 1 1 CV3190 100 WS1 DLFC 10 0 GPM ...

Page 23: ... 6 5 GPM FOR 3 4 1 CV3162 075 WS1 DLFC 7 5 GPM FOR 3 4 1 CV3162 090 WS1 DLFC 9 0 GPM FOR 3 4 1 CV3162 100 WS1 DLFC 10 0 GPM FOR 3 4 1 CV3190 090 WS1 DLFC 9 0 GPM FOR 1 1 CV3190 100 WS1 DLFC 10 0 GPM FOR 1 1 CV3190 110 WS1 DLFC 11 0 GPM FOR 1 1 CV3190 130 WS1 DLFC 13 0 GPM FOR 1 1 CV3190 150 WS1 DLFC 15 0 GPM FOR 1 1 CV3190 170 WS1 DLFC 17 0 GPM FOR 1 1 CV3190 200 WS1 DLFC 20 0 GPM FOR 1 1 CV3190 2...

Page 24: ...DY ASSEMBLY F M 1 13 CV3151 WS1 NUT QC 1 14 CV3150 WS1 SPLIT RING 1 15 CV3105 O RING 215 1 CV3070FF NO HARD WATER BYPASS 1 1 25 F F ASSEMBLY CV3070FM NO HARD WATER BYPASS 1 1 25 F M ASSEMBLY 1 5 NHWBP ASSEMBLIES Item No Part No Description Qty 1 CV3073 MAV NOWHBY COVER ASSEMBLY 1 2 CV3476 WS MOTOR ASSEMBLY 8 FT 1 3 CV3592 SCREW 8 3 4 PHPN T 25 SS 1 4 CV3262 01 WS1 5 2 ALT 2BY REDUCTION GEAR COVER ...

Page 25: ...ALT 2BY REDUCTION GEAR COVER ASSEMBLY 1 5 CV3110 WS1 DRIVE REDUCING GEAR 12 x 36 1 6 CV3264 WS2 BYPASS REDUCTION GEAR AXLE 1 7 CV3642 SCREW 1 4 20 x 1 1 4 BHSCS SS 1 8 CV3078 MAV NOHWBY 2 DRIVE ASSEMBLY 1 9 CV3634 01 MAV NOHWBY 2 PISTON 1 10 CV3887 WS2 NHWBY STACK ASSEMBLY 1 11 CV3828 01 WS2 NHWBY BODY M x F NPT 1 NOT SHOWN CV3805 STRAIN RELIEF COVER KIT 1 CV3098 MOTOR ALT VALVE 2 NPT REV2 ASSEMBL...

Page 26: ...ASS REDUCTION GEAR AXLE 1 7 CV3527 SCREW 1 4 20 x 3 4 BHSCS SS 1 8 CV3072 MAV NOWHBY 1 1 25 1 5 DRIVE ASSEMBLY 1 9 CV3506 01 MAV NOHRD 1 1 25 1 5 PISTON 1 10 CV3074 MAV NOHWBY 1 1 25 1 5 STACK ASSEMBLY 1 11 CV3504FF MAV BODY 1 1 25 ASSEMBLY F F 1 12 CV3504MM MAV BODY 1 1 25 ASSEMBLY M M 1 13 CV3151 WS1 NUT QC 1 14 CV3150 WS1 SPLIT RING 1 15 CV3105 O RING 215 1 NOT SHOWN CV3474 WS ALT MAV 1 1 25 CO...

Page 27: ... 1 5 NPT 1 NOT SHOWN CV3474 WS ALT MAV 1 1 25 CORD 8 FT BLACK 1 CV3071 MOTOR ALT VALVE 1 5 NPT REV2 ASSEMBLY 1 CV3475 Option 1 2 MAV ASSEMBLIES Item No Part No Description Qty 1 CV3073 MAV NOWHBY COVER ASSEMBLY 1 2 CV3476 WS MOTOR ASSEMBLY 8 FT 1 3 CV3592 SCREW 8 3 4 PHPN T 25 SS 1 4 CV3262 01 WS1 5 2 ALT 2BY REDUCTION GEAR COVER ASSEMBLY 1 5 CV3110 WS1 DRIVE REDUCING GEAR 12 x 36 1 6 CV3264 WS2 B...

Page 28: ...39 15 ASSEMBLY 1 5 2 3 STAINLESS STEEL METER ASSEMBLIES Item No Part No Description Qty 1 CV3003 02 WS1 5 2L 2H METER COMMERCIAL ASY 1 CV3221 WS METER ASY 15 FT CORD INCLUDES ITEMS 2 4 1 2 CV3118 03 WS15 2 TURBINE ASY 1 3 CV3105 O RING 215 1 4 CV3501 WS15 2 TURBINE CLIP 1 5 CV3401 04 WS15 METER HOUSING 1 CV3754 01 WS2 METER HOUSING 1 CV3601 01 WS3 METER HOUSING 1 6 CV3632 METER RETAINING CLIP 1 CV...

Page 29: ...L FOR SALT GRID SIZES AVAILABILITY BRINE TANK INTERNALS INCLUDES SAFETY FLOAT BRINE LINE WELL CAP OVERFLOW Part No Description Qty BT1833 1 GUTS 1833 BT INTERNALS 5GPM 3 8 BRINE VALVE 1 BT1840 1 GUTS 1840 BT INTERNALS 5GPM 3 8 BRINE VALVE 1 BT2441 1 GUTS 2441 BT INTERNALS 5GPM 3 8 BRINE VALVE 1 BT2441 2 GUTS 2441 BT INTERNALS 1 2 BRINE VALVE 1 BT2450 1 GUTS 2450 BT INTERNALS 5GPM 3 8 BRINE VALVE 1...

Page 30: ...Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628 Fitting 2 1 PLASTIC MALE NPT Item Part No Description Qty CV3007 04 1 plastic male NPT assembly 2 4 CV3164 Fitting 2 1 1 4 PLASTIC MALE NPT Item Part No Description Qty CV3007 05 1 1 4 plastic male assembly 2 4 ...

Page 31: ...freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manner and condition of the original installation and is owned by the original owner This warranty does not cover expendable or misapplied medias or damages due to accident fire flood freezing or any other Act of God Water Right is not responsib...

Page 32: ...1900 Prospect Court Appleton WI 54914 CUSTOMCAREWATER COM 2019 Water Right Inc All rights reserved CustomCare is a quality product line manufactured by Water Right Inc MAN C43SOFT 1 2 RevA0719 ...

Reviews: