background image

Improper handling of your Avallon portable air condi  oner can cause serious damage to the appliance and/or to the 
user. Please read the following safety informa  on. This portable air condi  oner is designed for domes  c indoor use 
only. Do not use the unit for industrial or commercial use.  Any other use may invalidate the warranty. Please review 
the ra  ng label located on the rear panel of the unit for electrical and other technical data related to this unit. The 
unit must be used in a properly grounded wall outlet.  

Please read and follow the safety informa

Ɵ

 on listed below to 

reduce the risk of 

fi

 re, electric shock or injury.

• 

This unit is designed for indoor use only.

• 

Do not use the unit in extremely humid or wet environments.

• 

Do not spray water and wet the housing or control panel.

• 

Do not pull the unit by the cord.

• 

Always turn the unit o

  and unplug it from the outlet when cleaning.

• 

Unplug the unit if it is not going to be used for a long period of   me. 

• 

Do not operate the unit with a damaged plug or a loose socket.

• 

Use only the correct power supply with appropriate amperage.

• 

If the power cord is damaged, it must be replaced by the manufacturer, a service agent, or quali

fi

 ed technician. 

• 

Do not remove any part of the casing unless instructed by an authorized technician.

• 

This portable air condi  oner is not intended to be used by children.

• 

Children should be supervised to ensure that they do not play with this product.

• 

Do not allow children to play with the controls or drop any objects into the air outlets or vents. 

• 

Do not place objects or let any person sit on top of the unit. 

• 

Only use in the upright posi  on on a 

fl

 at, level surface and provide at least 20” of clearance from any walls or objects. 

• 

Route the power cord carefully to avoid a tripping hazard. 

• 

This unit is intended for domes  c use only. Do not use the portable air condi  oner for industrial or commercial use.  Any  

 

other use may invalidate the warranty.

 

Important Safety Informa  on

ELECTRICAL SAFETY

GENERAL SAFETY

 
Your portable air condi  oner is supplied with a Leakage-Current Detec  on and Interrup  on (LCDI) safety plug. This device pro-
vides protec  on to reduce the risk of 

fi

 re due to arcing faults in the power supply cord. Before using your portable air condi  on-

er, follow the instruc  ons below to ensure that the LCDI plug is working properly: 

1.  Plug the power cord to a grounded outlet.
2.  Press the TEST bu  on on the LCDI plug. This should trip the plug and cut the power to the air condi  oner. If the plug does not 
trip and you are able to turn on the unit, please contact  support.

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS.

Press the RESET bu  on to start using your air condi  oner. 

Do not use the TEST and RESET bu  ons as an ON/OFF switch.

Note: Electrical products should not be disposed of with household waste.  Please contact your local 
recycling center for more informa  on on how to recycle electronic waste.

Summary of Contents for APAC100W

Page 1: ...Installation Operation and Maintenance for your portable air conditioner PORTABLE AIR CONDITIONER Model APAC100W www avallon com 1 866 471 7427 USER S GUIDE ...

Page 2: ...ren should be supervised to ensure that they do not play with this product Do not allow children to play with the controls or drop any objects into the air outlets or vents Do not place objects or let any person sit on top of the unit Only use in the upright posi on on a flat level surface and provide at least 20 of clearance from any walls or objects Route the power cord carefully to avoid a trip...

Page 3: ...Instruc ons Before use make sure all packaging labels and materials are all removed from the unit Be sure to keep track of all in cluded parts and pieces before discarding packaging materials It is advised that you keep the original box and packaging materials in case you are ever to move or ship the appliance in the future This owner s manual is provided for reference use only Specifica ons may c...

Page 4: ... ra ngs label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number Serial Number Date of Purchase To be er serve you please do the following before contac ng customer service If you received a damaged product immediately contact t...

Page 5: ...ontal Louver Control Lever adjust manually Front Panel Air Outlet Castors 4 Con nuous Drain Outlet Upper Air Intake Evaporator Upper Air Filter behind grill Remote Sensor Lower Air Intake Evaporator Lower Air Filter behind grill Bo om Drain Outlet ...

Page 6: ...t to roll the unit over any objects The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or outlet of the unit Allow at least 20 of space from the wall for efficient air condi oning INSTALLATION IN A DOUBLEͳHUNG SASH WINDOW 1 Cut the foam seal to the proper length and a ach it to the window sill 2 A ach the window slider kit to the w...

Page 7: ...gainst the window slider kit 4 Finally cut the foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash INSTALLATION OF EXHAUST HOSE The exhaust hose and adaptor must be installed or removed in accordance with the usage mode Install for COOL and AUTO mode remove for FAN or DEHUMIDIFY mode 1 Install the window exhaust hose adapter as shown below 2 P...

Page 8: ...on nuous drain outlet Connect the drain hose adapter to end of hose and place the open end of the adapter directly over the drain area During cooling mode the once the water level of the bo om tray reaches capacity the unit will beep several mes and the digital display on the control panel will read P1 to indicate the water must be manually drained Carefully move the unit to a drain loca on and re...

Page 9: ...r this mode you cannot select a fan speed or adjust the temperature Make sure the exhaust hose is removed in this mode Auto OperaƟon Press the MODE bu on un l the AUTO indicator light comes on When the air condi oner is set in AUTO mode it will automa cally select cooling or fan depending on what temperature you have se lected and the current ambient temperature Under this mode you cannot select t...

Page 10: ...set temperature will increase by 1 º C 2 º F in 30 minutes The set temperature will then increase by another 1 º C 2 º F a er an addi onal 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature This ends the SLEEP mode and the unit will con nue to operate as originally programmed This feature is only available in COOLING and AUTO mod...

Page 11: ...the mer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warm er climate Minimize the heat sources direct sunlight computers servers people etc in the room Close all windows and doors Use the unit in a contained room For example a room with four walls and a ceiling instead of a par oned studio or wa...

Page 12: ... remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solu on if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly before reinstalling Clean the pre filter periodically If the unit is used in a dusty environment you may need to clean it on a weekly basis Never operate the unit without the pre filt...

Page 13: ...My air condi oner is making a loud noise The unit is not level A foreign object has jammed the fan The floor below the unit is uneven Make sure the unit is on a level surface Remove the object from the fan Move the unit to a level surface My air condi oner is making a con nuous metallic knocking or pinging sound Unit may have been shipped on its side Damaged compressor Shut off the unit Let the uni...

Page 14: ... doors Too many heat sources The room garage may be inadequately insulated The ambient temperature is too high Direct sunlight is hea ng the room The filter may be dusty or blocked Dirty condenser coils Obstructed air intake or exhaust ports The unit must be vented Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Clos...

Page 15: ...A INPUT POWER 1125W COLOR White REFRIGERANT R134a 10 2oz DIMENSIONS 29 1 2 x 13 11 16 x 15 HEIGHT X WIDTH X DEPTH WEIGHT 50 7 pounds NOTE Technical data and performance informa on is provided for reference only Specifica ons are subject to change Check the ra ng label on the portable air condi oner for the most accurate informa on ...

Page 16: ...llation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacement of defective parts beyond the initial 12 month period Products that have been modified to perform outside of specifications without the prior written permission of Avallon Products lost in ship ment or th...

Page 17: ...736 Bee Cave Rd STE 1 188 West Lake Hills TX 78746 Toll Free 1 866 471 7427 Web http www avallon com E mail service avallon com Product contents and specifications may change without notice Copyright 2015 Avallon Gobal LLC ...