23
When the unit is in an alarm state, the following screen is displayed
5.3 POOLeasy standby mode
To place the POOLeasy in standby mode, press the
▲
and
▼ keys simultaneously for 5 seconds.
To exit standby mode, repeat the same operation.
5.4 POOLeasy priming
1° Place the POOLeasy in standby mode by pressing the
▲
and
▼ keys simultaneously for 5 seconds.
2°
Press the
MENU/ESC
and
CAL/OK
keys simultaneously for the desired time to prime the pump.
3° Exit standby mode by again pressing
▲
and
▼
simultaneously.
5.5 Principle of operation
The POOLeasy adjusts its dosing proportionally to demand. This means that it will dose less if the displayed
measurement is close to the setpoint (desired pH). To dose less, the POOLeasy inserts increasingly long
pauses between increasingly short operating times.
This is why the unit often has the pump stopped when the displayed value is not the same as the setpoint
value.
This is normal and the unit displays the
hourglass icon
Adjusting pH slowly preserves the natural quality of your water.
After 30 minutes without pressing any keys, the backlighting is switched off to save energy. Briefly pressing
SET
or
CAL
re-activates this.
6. Electrical terminals
6.1 Terminal markings
*****
OVERDOSING ALARM
Simply press
CAL/OK
to cancel the
alarm.
1 and 2
Filtration pump detection
(230Vac)
3
Not connected
4 and 5
Pre-powered 230Vac outlet for auxiliary
pump or solenoid valve
6
Not connected
7 and 8
Alarm output, dry contact without
voltage
9
Not connected
10 and 11
Dry-contact level detector input
12 to 14
not used
Summary of Contents for POOLeasy pH
Page 1: ...INSTRUCTIONS AND USER MANUAL POOLeasy pH POOLeasy Rx Power at the service of water...
Page 15: ...12 STEP 6 Securization on the pipe 1 50 pipe 2 63 pipe K C L K C L O...
Page 16: ...13 Vertical...
Page 20: ...17 STEP 10 Installation of the short probe 80mm G J 1 2 3...
Page 29: ...26 7 3 2 Installation of a long probe 120mm J G P 1 2 3...