22
5.2.3 Guide for setting activation time for the pH or Redox pumps
Water volume
M3
Pump Acti Time
S / 0.1 pH
Pump Acti Time
S / mV
From 1 to 10
3
1
From 11 to 20
6
2
From 21 to 40
10
3
From 41 to 80
20
6
From 91 to 120
25
-
From 130 to 150
30
-
The values given in this table are indicative and should be adjusted as a function of the configuration and
use of your pool.
5.2.4 Overdose alarm settings
The pump blocks its dosing and displays an alarm message when it has dosed more than the volume
indicated in the alarm menu for 4 consecutive hours. This alarm allows dynamic monitoring of any potential
overdosing.
HOLD DOWN THE
MENU/ESC
KEY for 5
seconds
Press CAL/OK
several times
(4 times) until you
enter the OVERDOSE ALARM menu
OVERDOSING ALARM
0.05 L/4 Hrs
Adjusting the overdose alarm: above the defined threshold,
the pump enters a state of alarm and requires that the
CAL/OK
button be pressed to start again. To disable the alarm,
adjust the threshold to 0 L/h (OFF).
Average information:
1 L of acid brings pH down by 0.3 in a pool of 100 M3
1 L of chlorine adds 1 ppm in a pool of 100 m3
If the threshold is set to 0.00 L/h
(OFF), the alarm is disabled. Press
MENU/ESC
to exit.
ALARM DISABLED
48h
Possibility to disable the alarm for 24h
or 48h to simplify startup, for
example.
OFF to enable the alarm without
period.
Summary of Contents for POOLeasy pH
Page 1: ...INSTRUCTIONS AND USER MANUAL POOLeasy pH POOLeasy Rx Power at the service of water...
Page 15: ...12 STEP 6 Securization on the pipe 1 50 pipe 2 63 pipe K C L K C L O...
Page 16: ...13 Vertical...
Page 20: ...17 STEP 10 Installation of the short probe 80mm G J 1 2 3...
Page 29: ...26 7 3 2 Installation of a long probe 120mm J G P 1 2 3...