PANDuo pH Turboxy
NOT044ENV02
21
5.3
Alarms and displayed symbols
Message
Meaning
Action
/ and \ alternatives
The pump is currently dosing
Dosing has stopped :
-
Either in the pause cycle
-
Either by the activation delay
Wait for:
-
The end of the pause cycle
-
The end of the activation delay
↑
for the pH: dosage of the pH +
(alkaline)
for Cl: dosage of disinfectant
↓
for the pH: dosage of the pH-(acid)
CALIBRATION ERR.
Calibration impossible
-
Check state of calibration solution
-
Clean the sensor
-
Replace the sensor
EMPTY TANK
The dosed fluid reservoir is empty
-
Refill the corresponding reservoir
with fluid
MEASURE TOO LOW pH mode : measured pH < 5 pH
Check pool water parameters
TAC > 100 mg/L
Check the status of the probes cable
MEASURE TOO HIGH pH mode: Measured pH > pH 9
Cl mode : measurement > 4 ppm
Check pool water parameters
TAC > 100 mg/L
FILTRATION OFF
The filtration pump is not
operating.The PAN DUO PH TURBOXY is
therefore paused
OVERDOSING
ALARM
The PAN DUO PH TURBOXY has dosed
more than the threshold
defined in the settings
Refer to section 4.4.4 19page 19
Signet non défini.
!
Alarm setting.
Refer to the alarm message displayed on
the screen
ISSUE PROBE CONN The Turboxy probe does not
communicate any more with PAN DUO
PH TURBOXY
Verify the state of the cable and the
connections
*
The star flashes approximately every
two minutes at the rate of the radio
communication.