Instructions and user manua
l
PANDuo pH Turboxy
NOT044ENV02
16
4.4
Device settings
4.4.1
pH menu
In
fo
:
th
e d
ev
ic
e re
tu
rn
s
to
th
e d
e
faul
t d
is
p
lay a
fte
r 1 mi
n
u
te
w
ith
o
u
t ke
yp
re
ss
es
PUMP FLOW RATE
1.5 l/h
OVERDOSING ALARM
0.00 l (OFF)
↓
7.5pH 1.2Cl↑
LANGUAGE
ENGLISH
PROPORTIONNAL TIME :
proportional from 1 to 60
s/0.1pH
FIXED TIME:
Fixed from 3 to 300s/300s
Tip
PRESS THE
ESC
KEY AT ANY TIME TO EXIT
MENU.
PUMP FLOW RATE :
pH pump flowrate information (no setting)
OVERDOSING ALARM :
Refer to section
Erreur ! Source du renvoi
introuvable.
LANGUAGES :
FRANÇAIS ENGLISH DEUTSCH NEDERLANDS
PORTUGUES ESPANOL ITALIANO
PUMP ACTIVA.TYPE
PROPORTIONNAL
PUMP ACTIVATION TYPE :
PROPORTIONNAL (by default) / FIXED
PUMP ACTIVE TIME
20s/0.1pH
CONFIGURATION
pH
CONFIGURATION :
Cl / pH / SYS
↓7.5pH
SET
CAL
DOSING MODE
ACID (pH-)
DOSING MODE :
ACID (pH-)
by default
/ ALKALINE (pH+)
1.2Cl↑
SET
CAL
PRIMING
PRIMING :
Upward: started by the hanging pump 30 s
downward: stop of the pump
MEASURE OFFSET
0.00 pH
MEASURE OFFSET:
From -0.4 to 0.4 pH