The  Set  Temperature  Display  Area  shows  the  temperature  the  unit  is 
set  to  achieve  when  operating.  This  temperature  can  be  increased  or 
decreased using the TEMPERATURE UP & DOWN buttons. 
 

In  order  to  achieve  the  best  results  we  recommend  that  a  setting  of  between  22C  and 
24C will give the best results in terms of room comfort. Constant changes in set tempera-
ture will not give better comfort but will increase energy consumption. Operating the unit 
with an abnormally low set temperature in cooling or abnormally high set temperature in 
heating for extended periods may also cause erroneous operation. 

The Fan & Louver Display Area shows the fan speed and also whether 
the automatic swing louver is operational. 
 

To  start  or  stop  the  swing  louver  mechanism  press  the  SWING  button.  All  four  louvers 
operate simultaneously and can not be controlled individually. This function can only be 
set when the unit is running. 
 
To change the fan speed press the FAN button when the unit is running. This will scroll 
between high, medium, low and automatic fan speeds. 

Swing Louver 

Low Fan Speed  Medium Fan Speed  High Fan Speed 

Automatic  Fan  Speed  is  shown  by  the  display  continually  changing  from  low  to  me-
dium to high fan speed. 
 
In  order  to  prevent  malfunction  it  is  strongly  recommended  not  to  use  the  low  or 
medium  fan speed settings when using the unit in cooling or automatic modes with a 
set temperature below 21C or in heating or automatic modes above 25C. Under cer-
tain conditions the units internal controls may over ride the fan speed selected by the 
user. 

9  

 

The Output Device Display Area is designed to show which of your sys-
tems internal components are operating at that moment in time, except 
for the Indoor Fan and Swing Louver which are shown separately in the 
Fan  &  Louver  Display  Area.  It  can  also  display  if  the  keyboard  lock  is 
set. 

The  Internal  Drain  Pump  is  used  to  remove  condensate  water  produced  during 
cooling, automatic and dry modes from the indoor unit. 

The  Reversing  Valve  is  used  to  reverse  the  flow  of  refrigerant  in  order  to  allow 
the unit to heat instead of cool.  This is lit in heating mode. 

The Outdoor Fan is used to reject heat from the room in cooling or dry modes or 
collect heat from outside in heating mode. 

The compressor is used to pump refrigerant around the system to allow the unit 
to heat or cool. It is located in the outdoor unit. 

The electric heat symbol is used to show when an optional electric heater device 
is  energised.  Your  Highcool  unit  does  not  have  this  heater  and  if  it  is  displayed 
you can cancel it using the HEATER button. It has no effect on your unit. 

The  Defrost  Symbol  shows  when  the  unit  is  in  heating  but  has  stopped  to  melt 
any  ice  formed  on  the  outdoor  heat  exchanger.  This  will  happen  from  time  to 
time to allow the system to operate efficiently. 

The  Keyboard  Lock  is  used  to  prevent  unauthorised  access  to  the  controller. 
When  it  is  lit  none  of  the  keys  on  the  controller  can  be  used.  This  allows  the 
operator  to  set  the  units  operating  mode  and  start  /  stop  times  then  prevent 
others from interfering with the operation of the system. It is enabled or disabled 
by pressing and holding the RESET button for six seconds. 

Summary of Contents for Highcool Series

Page 1: ...urposes E OE Read the Manual Risk of Electric Shock Unit is Remotely controlled may start without warning WARNING This air conditioner is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their s...

Page 2: ...perate your Highcool cassette split system in order to get the most from it CONTENTS P2 Introduction P3 General Description P4 Display Section P5 Control Buttons P6 9 Understanding the Display P10 12 Operating the Controller P13 Caring for the Environment P14 Appendix 1 Fault Codes P15 Appendix 2 Engineers Notes P15 Appendix 3 Timer Chart P15 Fault Code Log 15 Appendix 2 Notes for Engineer The con...

Page 3: ...rip Repair Safety Device Tripped Er05 Critical Low Pressure Switch Trip Repair Safety Device Tripped Er06 Critical High Discharge Temperature Repair Safety Device Tripped Er07 Critical Overcurrent Protection Tripped Repair Safety Device Tripped Er08 Critical Comms Fail Indoor to Outdoor Repair Broken Cable or Interference Er11 Critical Drainage Failure Repair Blocked Drains Er12 Critical Electric ...

Page 4: ...inimum Use the time clock to operate your unit only when it is needed If not using the time clock remember to switch the unit off when a room is unoccupied Choose the operation mode best suited to the season Cooling mode in summer will prevent the heating coming on while Heating mode in winter will prevent unnecessary cooling Use automatic mode only during intermediate periods when both heating an...

Page 5: ...ON will allow you to enter Engineer Setup mode Details are available in the Service Manual Parameters in the Engineer Setup mode should only be changed by suitably qualified personnel with a copy of the Service Manual to hand If you enter Engineer Setup mode by mistake press RESET to leave without changing any important system parameters 5 Control Buttons 1 2 3 4 5 6 7 8 9 10 Opening the panel on ...

Page 6: ... to be used to prevent the room temperature dropping below the set temperature during winter use For your comfort we recommend not setting the temperature above 24C in heating mode 11 What do you want the unit to do Pressing the mode button scrolls between automatic cooling dry fan only and heating modes Choose the mode most appropriate to your needs Automatic will engage whichever mode is necessa...

Page 7: ... controller to switch the unit on or off 3 If the unit is on then the display LED will glow green If it is off then it will glow red 7 The Timer Area is only lit during timer operation and shows the time when the timer will next turn the unit on or off If the unit is in timer operation and the OPERATION button is pressed then the timer area will advance to the next applicable setting as the OPERAT...

Page 8: ...s internal controls may over ride the fan speed selected by the user 9 The Output Device Display Area is designed to show which of your sys tems internal components are operating at that moment in time except for the Indoor Fan and Swing Louver which are shown separately in the Fan Louver Display Area It can also display if the keyboard lock is set The Internal Drain Pump is used to remove condens...

Reviews: