AUX air conditioner service manual
When the air-conditioner runs the heating mode, the loop of the solenoid guiding valve is electrified
and the iron core drives the valve bowl to move right. Then the capillary tube a connects to d (in high
pressure) and b connects to c (in low pressure). Because the capillaries a and d connect with the
discharge pipe of compressor, they will form a high-pressure zone being filled with the high-pressure
gas. However the capillaries b and c connect with the suction pipe of the compressor, they will form a
low-pressure zone. At this moment, the piston moves to the right side by pressure, then, D connects to
E, the high-pressure gas refrigerant in D pipe flows into the indoor heat exchanger (as condenser) for
heat transmission process passing through pipe E, and enters into the outdoor heat-exchanger
(evaporator) passing through capillary tube. Finally, it will enter into pipe S from pipe C and return
back to the compressor for concluding a heating cycle. The flow process is indicated in Chart 2:
②
one-way Valve
Check valve is also called anti-reverse valve. it permits the refrigerant to flow in only one direction in
the refrigeration system, and to be installed in the pipes for preventing process flow from
reversing. It is mainly applied in the heat pump air-conditioner and adopted as the assistant to the
electromagnetic reversing valve for changing the refrigerant’s flow direction and the system’s pressure.
Generally, there is an arrow marked on the outer surface of the one-way valve for indicating the flow
direction of the refrigerant.
The one-way valve is divided into the spherical valve and the needle valve. They are in the simple
structure. For example in the below picture, when the refrigerant flows in the direction as the arrow
indicates and when the pressure at A side is higher than the one at B side, then the steel ball (or valve
needle) moves to the left side, and the refrigerant flows from A to B, the one-way valve opens.
However, when the refrigerant flows in a reverse direction and when the pressure at B side is higher
than the one at A side, then the steel ball (or valve needle) moves to the right side, which jams the
25
Summary of Contents for E Series
Page 1: ......
Page 32: ...AUX air conditioner service manual The other parts 29 ...
Page 33: ...AUX air conditioner service manual 30 ...
Page 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Page 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Page 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Page 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Page 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Page 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Page 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Page 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Page 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Page 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Page 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Page 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Page 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Page 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Page 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Page 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Page 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Page 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Page 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Page 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Page 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Page 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Page 149: ...AUX air conditioner service manual 146 ...
Page 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Page 166: ...AUX air conditioner service manual 163 ...
Page 240: ......