AUX air conditioner service manual
22
he air-conditioners in different specification have different capacity So, the throttling component in
he capillary tube is a slim and long copper pipe with a small aperture. The inner diameter of it is
he capillary tube is a kind of throttling component applied in the refrigeration system. It is welded
Liquid distributor
with a large evaporating surface area, usually, the coil pipes of the evaporator
he liquid distributor of the air-conditioner generally consists of a coniform unit body and a throttling
T
controlling the different flux shall be different. The throttling component type in the general
air-conditioner includes the capillary tubes type and expansion valve type. But only capillary tubes
applied in the home use air-conditioner because of the small flux it is. The following is the detailed
introduction for it.
T
1mm—2mm, and the length is 500mm—1000mm. With the properties of simple structure, easy
machining, low cost and reliability, especially enough capability for the throttling need at a stable
indoor room temperature; it’s popularly applied in the practice. However, it has a weak
accommodating function, which can be workable under a rating working status but can’t adjust the
flux following with the variety of the load of the refrigeration system.
T
between the condenser and the evaporator for the function of reducing pressure and throttling flux. It
can prevent the liquefied refrigerant at a normal temperature and pressure of the condenser entering
into the evaporator directly so as to reduce the pressure of the evaporator in favor of the evaporation
of the refrigerant. After stopping the operation of the compressor, it can maintain a balance between
the low-pressure part and the high-pressure part for the convenient re-start of the compressor. The
resistance will be reduced and the flux of the refrigerant will be increased if enlarging the inner
diameter or shortening the length of the capillary tubes, and on the contrary if otherwise. The capillary
tubes must match the refrigerating devices and cannot be replaced freely, especially when the inner
diameter, the roughness of the inner surface and the length are in difference, it may affect the normal
operation of the refrigeration system badly. As the narrowest part of the refrigeration system, the
capillary tubes may easily to be jammed. The figuration of the capillary tubes is indicated in the
picture 2-6 as the below.
⑹
To the air-conditioner
are ranked together side by side. For enhancing the evaporation efficiency, the liquid distributor is in
need to be assembled for having the refrigerant enter into the evaporator equably in various routes.
T
nozzle. The refrigerant enters inside through the nozzle and to be guided in different ways following
the inner surface of the cone. There are many equally distributed holes at the bottom of the cone,
which are connected to the various accesses of the evaporator through the capillary tubes. When the
refrigerant flows through the nozzle of the throttling liquid distributor, its flow speed will be
accelerated due to the sudden contraction to the section area of the stream, and force the liquid and gas
mix together equally to flow into the capillary tubes which connect to the throttling ring. Consequently,
the flows will enter inside the various tubes of the evaporator so as to enhance the evaporating
efficiency for the evaporator. Refer to the below picture 2-7 of the figure of liquor separator.
Summary of Contents for E Series
Page 1: ......
Page 32: ...AUX air conditioner service manual The other parts 29 ...
Page 33: ...AUX air conditioner service manual 30 ...
Page 102: ...AUX air conditioner service manual 99 Outdoor unit exploded picture ...
Page 104: ...AUX air conditioner service manual 101 2 ASW H09A4 EC Indoor unit exploded picture ...
Page 106: ...AUX air conditioner service manual 103 Outdoor unit exploded picture ...
Page 108: ...AUX air conditioner service manual 105 3 ASW H12A4 ET Indoor unit exploded picture ...
Page 110: ...AUX air conditioner service manual 107 Outdoor unit exploded picture ...
Page 112: ...AUX air conditioner service manual 109 4 ASW H12A4 EC Indoor unit exploded picture ...
Page 114: ...AUX air conditioner service manual 111 Outdoor unit exploded picture ...
Page 116: ...AUX air conditioner service manual 113 5 ASW H18B4 ET Indoor unit exploded picture ...
Page 118: ...AUX air conditioner service manual 115 Outdoor unit exploded picture ...
Page 120: ...AUX air conditioner service manual 117 6 ASW H24B4 ET Indoor unit exploded picture ...
Page 122: ...AUX air conditioner service manual 119 Outdoor unit exploded picture ...
Page 126: ...AUX air conditioner service manual 123 Outdoor unit exploded picture ...
Page 128: ...AUX air conditioner service manual 125 2 ASW H09A4 HSL Indoor unit exploded picture ...
Page 130: ...AUX air conditioner service manual 127 Outdoor unit exploded picture ...
Page 132: ...AUX air conditioner service manual 129 3 ASW H09A4 HS Indoor unit exploded picture ...
Page 134: ...AUX air conditioner service manual 131 Outdoor unit exploded picture ...
Page 136: ...AUX air conditioner service manual 133 4 ASW H18B4 HS Indoor unit exploded picture ...
Page 138: ...AUX air conditioner service manual 135 Outdoor unit exploded picture ...
Page 140: ...AUX air conditioner service manual 137 5 ASW H24B4 HS Indoor unit exploded picture ...
Page 142: ...AUX air conditioner service manual 139 Outdoor unit exploded picture ...
Page 146: ...AUX air conditioner service manual 143 Outdoor unit exploded picture ...
Page 148: ...AUX air conditioner service manual 145 2 ASF H41A5 C Indoor unit exploded picture ...
Page 149: ...AUX air conditioner service manual 146 ...
Page 151: ...AUX air conditioner service manual 148 Outdoor unit exploded picture ...
Page 166: ...AUX air conditioner service manual 163 ...
Page 240: ......