1
35
At this mode, the outdoor fan motor will keep off while the indoor fan motor runs at set speed.
You can select high, medium, low fan speed with the remote control; the movement of vane
is the same as that of cooling mode; Timer, memory, negative ion functions are available at
this mode.
8-6 Fan Mode
8.Function Exposition
3.When first powered, the 3-minute protection will be off ,and the outdoor fan motor will run
after the compressor keeps running for 2s;
4.When the indoor fan motor is running, the vane can be set move freely as the that of the
cooling mode;
5.When TE < 0 C for 10s and the compressor keeps running for more than 5 minutes,
turn off the compressor and outdoor fan motor, the indoor fan will run at the set speed;
if TE>7 C, it will quit the protection;
6.When TE > 64 C and lasts for 10s,turn off the compressor and outdoor fan motor,
and the compressor can work well when TE<62 C,then the indoor fan motor will run at set
speed if it is set manually; it will run at low speed if it is set automatically;
7.Timer, sleep, memory, negative ion and I feel functions are available at this mode.
8-7 Heating Mode
The temperature can be adjusted between 16 C to 32 C by pressing the + or
button on the
remote control. You can select automatic, high, medium, and low speed by pressing the fan
speed button. Other details are as follows:
5.At heating mode, the movement of the vane is controlled by pressing the SWING button;
6.When first powered, the 3-minute protection function will be off and the compressor will
be on after the 4-way valve keeps running for 10s, the outdoor fan motor will run after the
compressor keeps running for 2s;turn TS down to TS<TA-3, then the compressor will be
off immediately without the limitation of the 3-minute protection;
7.Timer, sleep, memory, negative ion, I feel functions are available at this mode;
8.When first powered, the 4-way valve will be on immediately, the compressor 10s later;
when the compressor is off, the 4-way valve will be off in 2 minutes and 50s after the air
conditioner is off or mode is shifted; when the compressor is off, the 4-way will be off
immediately once the air-conditioner is powered off.
1.When TA-3-TS<-1 C and the compressor and outdoor fan motor are turned on after the 3-
minute protection duration, the indoor fan motor will run at the cold air prevention mode,
and the TA displayed on the LED includes 3 C temperature compensation;
2.When TA-3-TS>-1 C and the compressor and outdoor fan motor are turned on after the 3-
minute protection duration, the indoor fan motor will run at cold air prevention mode, and
the TA displayed on the LED includes 3 C temperature compensation;
3.When TA-3 equals TS, the status will remain unchanged;
4.Automatic fan speed control:
when TA<TS, the fan motor runs at high speed;
when TS<TA<TS+2 C, the fan motor runs at medium speed;
when TA>TS+2 C, the fan motor runs at low speed;
When the fan speed is shifted from low to high, the 3-minute protection will be off; it will be on
when the fan speed is shifted from high to low.
Summary of Contents for ASW-09A4/E Series
Page 3: ...2 1 Appearance 2 Technical Specification 2 ...
Page 4: ...OUTDOOR UNIT INDOOR UNIT 2 1 Appearance continue 2 Technical Specification 3 ...
Page 15: ...4 Wiring Diagram 4 1 ASW H 24B4 E Indoor Unit 14 ...
Page 27: ...Fig 2 1 26 6 Explosion View And Parts List 6 3 door Unit Explosion View Of Out ...
Page 44: ......