1h
2h
1
39
Set temperature
Original set
temperature
7h(
Quit the sleeping function
and powered off automatically)
Go down
for 2 C
Another 2 C
Sleeping function at cooling mode
Causes
Display
Failures
Stop running
Stop running
Stop running
Pg abnormal feedback
Ta abnormal
Te abnormal
When the air-conditioner fails, the LED on the display plate will display the relevant failure
code. The details are as follows:
The longest timing interval is 24 hours( 1minute as the unit), and once the timer is set,
it will not be changed even modes are shifted and the indicator will be lighten.
1.TIMER off
This can only be set when the air-conditioner is running, and the timing scope is 1min-24
hours, it will automatically powered off once set.
2.TIMER on
This can only be set when the air-conditioner is off, and the timing scope is 1min-24 hours,
it will automatically run once set.
The original timer and sleep function will be automatically cancelled if the air-conditioner
is powered on or off again.
Press the forced switch to power the air-conditioner on, the buzzer rings two times, signalling
the inspection process:
The electric heater is on, the indoor fan runs at high speed, and the LED and there indicators
are lighten for 1s .The LED will display
11
22
33
44
in turn for 1s,then the
running indicator for 1s,TIMER indicator for 1s, SLEEP indicator for 1s and the each phase
of the step motor electrified for 1s .
Then the indoor fan motor runs at both low and medium speed for 1s, the compressor moves
for 1s,the 4-way valve for 1s,the outdoor fan motor for 1s,the negative ion for 1s and then the
buzzer rings, the electric heater runs for 30s and then stops. Then the air-conditioner comes
to the hold-on mode, the self-inspection is completed.
8
11 Timer Function
8-12 Self-inspection
8-13 Failure Indicating
8.Function Exposition
Summary of Contents for ASW-09A4/E Series
Page 3: ...2 1 Appearance 2 Technical Specification 2 ...
Page 4: ...OUTDOOR UNIT INDOOR UNIT 2 1 Appearance continue 2 Technical Specification 3 ...
Page 15: ...4 Wiring Diagram 4 1 ASW H 24B4 E Indoor Unit 14 ...
Page 27: ...Fig 2 1 26 6 Explosion View And Parts List 6 3 door Unit Explosion View Of Out ...
Page 44: ......