2.4 F Series (12K,18K)
Model
Indoor
Unit
AMWM-H12/4R3(F*) AMWM-H18/4R3(F*)
Capacity
Cooling
Btu/h
12285(5800-12625) 17747(8530-19790)
kW
3.50(1.70-3.70)
5.27(2.50-5.80)
Heating
Btu/h
12625(5120-12625) 18085(7680-19790)
kW
3.50(1.50-3.70)
5.37(2.25-5.80)
Electric Data
Power Supply
V~,Hz,
Ph
220
~
240,50,1
220
~
240,50,1
Cooling Power Input
W
40(12
~
68)
63(16
~
88)
Heating Power Input
W
40(12
~
68)
63(16
~
88)
Indoor
Fan Motor
Model
/
YYK12-4B
D-310-30-8
Output Power
W
12
30
Speed (H/M/L)
r/min
1150
1330
Indoor Coil
a. Number Of Row
/
2
2
b.Tube Pitch(a)x Row
Pitch(b)
mm
20.5x 12.7
20.5x 12.7
c.Fin Pitch
mm
1.3
1.4
d.Fin Material
/
Hydrophilic aluminum fin
e.Tube Outside
Dia.And Material
mm
φ7
,
Inner grooved
Performance
Air Flow Volume
m3/h
600
850
Sound Pressure Noise
Level
dB(A)
42
45
Dimension
Net Dimension
(W*D*H)
mm
750×285×200
900×310×225
Packing Dimension
(W*D*H)
mm
820×347×277
970×382×302
Weight
Net
kg
8
12
Gross
kg
10
14
Refrigerant Type
/
R32
R32
Pipe Diameter
Liquid Side
mm
(inch)
6.35(1/4)
6.35(1/4)
Gas Side
mm
(inch)
9.52(3/8)
12.7(1/2)
Drainage
mm
16.5
16.5
Stuffing
Quantity
20/40/40H
unit
384/768/864
252/518/592
Summary of Contents for AMWM-H07/4R3
Page 54: ...AUX DC Inverter Free Match 50HZ R32 3 Ceiling Floor 09K 12K 18K 929 660 245 841 205 ...
Page 57: ...AUX DC Inverter Free Match 50HZ R32 57 5 Outdoor Unit 5 1 14K 18K 545 800 545 822 315 315 ...
Page 58: ...AUX DC Inverter Free Match 50HZ R32 5 2 21K 27K 834 540 655 854 335 328 ...
Page 59: ...AUX DC Inverter Free Match 50HZ R32 59 5 3 36K 42K 985 675 808 1000 409 395 ...
Page 64: ...AUX DC Inverter Free Match 50HZ R32 3 Ceiling Floor 09k 12k 18k ...
Page 65: ...AUX DC Inverter Free Match 50HZ R32 65 4 Duct 07K 09K 12K 18K ...
Page 67: ...AUX DC Inverter Free Match 50HZ R32 67 5 1 36K 42K ...
Page 73: ...AUX DC Inverter Free Match 50HZ R32 73 Part8 Static pressure curve 1 07K 09K Duct ...
Page 74: ...AUX DC Inverter Free Match 50HZ R32 2 12K Duct ...
Page 75: ...AUX DC Inverter Free Match 50HZ R32 75 3 18K Duct ...
Page 81: ...AUX DC Inverter Free Match 50HZ R32 81 ...
Page 122: ...AUX DC Inverter Free Match 50HZ R32 5 3 2 1 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...
Page 135: ...AUX DC Inverter Free Match 50HZ R32 135 2 Cassette 09K 12K 18K ...
Page 139: ...AUX DC Inverter Free Match 50HZ R32 139 4 Duct 4 1 07K 09K 12K ...
Page 141: ...AUX DC Inverter Free Match 50HZ R32 141 4 2 18K ...
Page 143: ...AUX DC Inverter Free Match 50HZ R32 143 5 Outdoor Unit 5 1 14K 18K ...
Page 145: ...AUX DC Inverter Free Match 50HZ R32 145 ...
Page 147: ...AUX DC Inverter Free Match 50HZ R32 147 5 3 36K ...
Page 149: ...AUX DC Inverter Free Match 50HZ R32 149 5 4 42K ...
Page 155: ...AUX DC Inverter Free Match 50HZ R32 155 4 Cassette 4 1 Installation drawing ...
Page 160: ...AUX DC Inverter Free Match 50HZ R32 ...
Page 181: ...AUX DC Inverter Free Match 50HZ R32 181 1 2 21K 27K Main PCB and Driver modular ...
Page 182: ...AUX DC Inverter Free Match 50HZ R32 1 3 36K 42K Main PCB ...
Page 183: ...AUX DC Inverter Free Match 50HZ R32 183 Drive Modular Board ...
Page 184: ...AUX DC Inverter Free Match 50HZ R32 2 Indoor Unit PCB 2 1 09K 12K 18K Cassette ...
Page 185: ...AUX DC Inverter Free Match 50HZ R32 185 2 2 09K 12K 18K Ceilling Floor ...
Page 186: ...AUX DC Inverter Free Match 50HZ R32 2 3 07k 09K 12K 18K Duct ...
Page 191: ...AUX DC Inverter Free Match 50HZ R32 191 Outdoor protection phase sequence ...
Page 193: ...AUX DC Inverter Free Match 50HZ R32 193 2 4 H6 low pressure protection ...
Page 195: ...AUX DC Inverter Free Match 50HZ R32 195 2 5 P5 High exhaust temperature protection ...
Page 196: ...AUX DC Inverter Free Match 50HZ R32 Cooling exhaust temperature protection ...
Page 197: ...AUX DC Inverter Free Match 50HZ R32 197 Heating exhaust temperature protection ...
Page 198: ...AUX DC Inverter Free Match 50HZ R32 2 6 H8 four way valve failure protection ...
Page 199: ...AUX DC Inverter Free Match 50HZ R32 199 2 7 Sensor failure protection ...