background image

AUX DC Inverter Free Match 50HZ 

R32

 

 

 

1.3 F Type ( 07K, 09K, 12K) 

 

 

 

1

2

3

4 5

6 7

8

9

10

11

12

13

15

16

17

18

19

20

21

14

Summary of Contents for AMWM-H07/4R3

Page 1: ...Technical Manual DC Inverter Free Match R32 ΑΓΗΝΩΡ A E ΟΜΙΛΟΣ ΕΤΑΙΡΙΩΝ ΤΟΥΡΝΙΚΙΩΤΗ ΓΕΝΙΚΟΙ ΑΝΤΙΠΡΟΣΩΠΟΙ ...

Page 2: ...AUX DC Inverter Free Match 50HZ R32 KΕΝΤΡΙΚΑ ΓΡΑΦΕΙΑ Λ ΑΘΗΝΩΝ 50 ΣΠ ΠΑΤΣΗ 8 10441 ΑΘΗΝΑ ΤΗΛ ΚΕΝΤΡΟ 210 5288888 FAX 210 5221261 SERVICE 210 5288832 4 ...

Page 3: ...nclature 7 2 Unit appearance 8 3 Combination Table 13 4 Accessories Included 17 Part2 Features 18 1 Outdoor Units 18 2 Wall Mounted 21 3 Four way Cassette 22 4 Ceiling Floor 23 5 Duct 24 6 WIFI Control 25 Part3 Piping System 26 1 14K 18K 26 2 21K 27K 26 3 36K 28 4 42K 29 Part4 Specification 30 ...

Page 4: ...Cassette 53 3 Ceiling Floor 54 4 Duct 55 5 Outdoor Unit 57 Part6 Electrical Principle Diagram 60 1 Wall Mounted 60 2 Cassette 63 3 Ceiling Floor 64 4 Duct 65 5 Outdoor Unit 66 Part7 Capacity Amendment 68 1 Operation range 68 2 Capacity amendment of different ambient temperature 68 3 Long piping length 70 4 Capacity amendment of different piping length 71 ...

Page 5: ...2K Duct 74 3 18K Duct 75 Part9 Controller 76 1 Controller 76 2 Parameters Setting 106 3 Room Card Function 111 4 Wifi Module 113 Part10 Explosive View 116 1 Wall Mounted 116 2 Cassette 135 3 Ceiling Floor 137 4 Duct 139 5 Outdoor Unit 143 Part11 Installation 151 1 Preparation 151 2 Precaution 152 3 Wall Mounted 153 4 Cassette 155 ...

Page 6: ...nnection piping installation 168 9 Emptying or vacuum 171 10 Insulation 173 11 Additional refrigerant charge 175 12 Electrical connection 176 Part12 PCB Instruction 180 1 Outdoor Unit PCB 180 2 Indoor Unit PCB 184 Part13 Trouble Shooting 187 1 Failure code display 187 2 Failure analysis 189 ...

Page 7: ...AUX DC Inverter Free Match 50HZ R32 7 Part1 General Information 1 Nomenclature Indoor Unit Outdoor Unit ...

Page 8: ...h AMWM H09 4R3 L 12 K Btu h AMWM H12 4R3 L 18 K Btu h AMWM H18 4R3 L F Series 07 K Btu h AMWM H07 4R3 F 09 K Btu h AMWM H09 4R3 F 12 K Btu h AMWM H12 4R3 F 18 K Btu h AMWM H18 4R3 F 24K Btu h AMWM H24 4R3 F J Series 07 K Btu h AMWM H07 4R3 J 09 K Btu h AMWM H09 4R3 J 12 K Btu h AMWM H12 4R3 J 18 K Btu h AMWM H18 4R3 J 24K Btu h AMWM H24 4R3 J ...

Page 9: ...r Free Match 50HZ R32 9 2 2 Cassette Picture Capacity Range Mode Four way cassette 09 K Btu h AMCA H09 4R3A 12 K Btu h AMCA H12 4R3A 18 K Btu h AMCA H18 4R3A Standard Panel MB13A I MB13B I Optional Panel MB09A MB09B ...

Page 10: ...AUX DC Inverter Free Match 50HZ R32 2 3 Ceiling Floor Picture Capacity Range Mode Ceiling Floor 09 K Btu h AMCF H09 4R3A 12 K Btu h AMCF H12 4R3A 18 K Btu h AMCF H18 4R3A ...

Page 11: ...AUX DC Inverter Free Match 50HZ R32 11 2 4 Duct Picture Capacity Range Mode DUCT 07 K Btu h AMSD H07 4R3A 09 K Btu h AMSD H09 4R3A 12 K Btu h AMSD H12 4R3A 18 K Btu h AMSD H18 4R3A ...

Page 12: ...ree Match 50HZ R32 2 5 Outdoor Unit Capacity Btu 1 drive 2 14k 18k 1 drive 3 21k 27k AM2 H14 4DR3 AM3 H21 4DR3 AM2 H18 4DR3 AM3 H27 4DR3 Picture Capacity Btu 1 drive 4 36k 1 drive 5 42k AM4 H36 4DR3 AM5 H42 4DR3 Picture ...

Page 13: ...t Two Units Three Units 7 7 9 12 7 7 7 7 9 9 18 7 7 9 7 12 12 12 7 7 12 18 7 18 7 9 9 24 9 9 9 9 9 27K AM3 H27 4DR3 Suggested Combination 1 drive 3 One Unit Two Units Three Units 18 7 12 9 24 7 7 7 7 9 18 24 7 18 12 12 7 7 9 7 12 12 7 24 12 24 7 7 12 9 9 9 9 9 18 18 7 7 18 9 9 12 9 12 18 24 7 9 9 9 12 12 9 18 7 9 12 AM2 H18 4DR3 Suggested Combination 1 drive 2 One Unit Two Units 9 7 7 9 9 12 7 9 9...

Page 14: ...9 12 18 24 7 7 24 7 12 24 9 12 18 9 18 7 9 9 7 18 18 9 12 24 9 24 7 9 12 9 9 9 9 18 18 AM4 H36 4DR3 Suggested Combination 1 drive4 Four Units 7 7 7 7 7 7 9 18 7 9 12 18 7 7 7 9 7 7 12 12 7 12 12 12 7 7 7 12 7 7 12 18 9 9 9 9 7 7 7 18 7 9 9 9 9 9 9 12 7 7 7 24 7 9 9 12 9 9 9 18 7 7 9 9 7 9 9 18 9 9 12 12 7 7 9 12 7 9 12 12 9 12 12 12 42K AM5 H42 4DR3 Suggested Combination 1 drive5 One Unit Two Unit...

Page 15: ...2 7 9 12 24 12 12 12 12 7 7 7 9 7 7 12 18 7 12 12 12 12 12 12 18 7 7 7 12 7 7 12 24 9 9 9 9 7 7 7 18 7 9 9 9 9 9 9 12 7 7 7 24 7 9 9 12 9 9 9 18 7 7 9 9 7 9 9 18 9 9 12 12 7 7 9 12 7 9 12 12 9 12 12 12 7 7 9 18 7 9 12 18 9 12 12 18 AM5 H42 4DR3 Suggested Combination 1 drive5 Five Units 7 7 7 7 7 7 7 7 9 24 7 7 12 12 12 9 9 9 9 18 7 7 7 7 9 7 7 7 12 12 7 9 9 9 9 9 9 9 12 12 7 7 7 7 12 7 7 7 12 18 7...

Page 16: ...erter Free Match 50HZ R32 Note All of the above indoor unit can be freely matched and combined but must be installed strictly according to the above table or the cooling capacity and stability would be decreased ...

Page 17: ... 1 1 1 1 2 Drainage connector 1 1 1 1 1 1 3 Pipe adaptor 0 0 0 0 0 0 4 copper nuts 8 8 12 12 16 20 4 2 Indoor Units N Name QUANTITY Wall Mounted Duct Cassette Ceiling Floor 1 User manual 1 1 1 1 2 Remote control 1 0 1 1 3 Batteries for Remote Control 2 0 2 2 4 Touch screen wired Control 0 1 0 0 5 Panel screw 0 0 4 0 6 Drainage tube 0 1 1 1 7 Pipe adaptor 0 1 1 1 8 Thermal insulation pipe 0 2 2 2 ...

Page 18: ...igh efficiency DC Inverter compressor adjustable fan motor and advanced 180 sine wave vector driver the system can be higher than 6 1 in SEER and 4 0 in SCOP so as to meet the European and Australian new energy efficiency standards Reliability Stable cooling under 10 C and heating under 15 C outdoor environment temperature 180 Sine Wave Control DC inverter compressor uses 180 sine wave vector cont...

Page 19: ...y realize low noise and economical operation Space Saving Installation Up to 5 indoor units can be connected to a single outdoor unit which reduces the number of outdoor units required so as to save installation space Besides each indoor unit can controlled individually and they even needn t to be installed at the same time ...

Page 20: ...AUX DC Inverter Free Match 50HZ R32 EXV Regulation Each Indoor Unit adjusted by a EXV whole unit could achieve quick cooling heating and decrease throttling noise in indoor units ...

Page 21: ...A C it has following advantages Wall mounting installation combining with the decoration makes the room more elegant Flexible installation in anywhere in the wall and swing blowing makes you feel more comfortable 2 Ways Draining Connection Both left and right sides of unit are possible for drainage pipe connection easy for installation ...

Page 22: ...ng type A C it has following advantages Ceiling installation combining with the decoration makes the room more elegant Flexible installation in anywhere in the ceiling and 4 direction blowing makes you feel more comfortable Built in Drain Pump The built in drain pump can lift condensing water up to 700mm high from the drainage pan 7 0 0 m m ...

Page 23: ...ving room space it is also the updating Product for Floor Standing type A C 3D Air Swing Vertical and horizontal swing makes air below to every corner of the room Innovative Centrifugal Fan Innovative centrifugal fan provides larger air volume but lower noise making the air supply more quietly and smoothly Flexible Installation Can be vertically installed against the wall or horizontally installed...

Page 24: ...aving room space it is also the updating Product for Floor Standing type A C Flexible Air Intake Options Air intake from rear as standard from bottom is optional The size of the plate from bottom is the same as the flange from back which makes it convenient to change installation style due to different decoration requirements Ultra Slim Design The thickness is only 200mm save installation space ...

Page 25: ...AUX DC Inverter Free Match 50HZ R32 25 6 WIFI Control The optional WiFi modular makes it possible to monitor and control your AC while on the road through APP on your mobile phone or pad ...

Page 26: ...e Match 50HZ R32 Part3 Piping System 1 14K 18K 2 21K 27K SV0 Tcm Tdef Tao Td PMVB Tem Ta LPS1 Tas B FILTER SOUND REDUCER TLq A Ts FILTER FILTER PMVA OUTDOOR INDOOR SERVICE VALVE Tem Ta EVAP B EVAP A CONDENSER Tas A TLq B ...

Page 27: ...e Match 50HZ R32 27 SV0 Tcm Tdef Tao Td PMVC Tem Ta LPS1 Tas C FILTER SOUND REDUCER TLq B Ts FILTER FILTER PMVB OUTDOOR INDOOR SERVICE VALVE Tem Ta EVAP C EVAP B CONDENSER Tas B Tem Ta EVAP A TLq A FILTER PMVA Tas A TLq C ...

Page 28: ...3 36K SV0 Tcm Tdef HPS1 Tao Td LPS1 SOUND REDUCER Ts CONDENSER LGS OS EVAP D Tem Ta Tiq FILTER PMVA Tas Tem Ta EVAP A SERVICE VALVE Tiq FILTER PMVA Tas PMVC Tem Ta Tas FILTER Tiq FILTER FILTER PMVB OUTDOOR INDOOR Tem Ta EVAP C EVAP B Tas ...

Page 29: ...VAP E EVAP D LGS SV0 Tcm Tdef HPS1 Tao Td PMVC Tem Ta LPS1 Tas FILTER SOUND REDUCER Tiq Ts FILTER FILTER PMVB OUTDOOR INDOOR Tem Ta EVAP C EVAP B CONDENSER Tas Tem Ta EVAP A Tiq FILTER PMVA Tas Tem Ta SERVICE VALVE Tiq FILTER PMVA Tas Tem Ta Tas Tiq FILTER ...

Page 30: ...8 Indoor Fan Motor Model YYK18 4B YYK18 4B Output Power W 18 18 Speed H M L r min 1250 1250 Indoor Coil Number Of Row 2 2 Tube x Row Pitch mm 20 5x 12 7 20 5x 12 7 Fin Pitch mm 1 4 1 4 Fin Material Hydrophilic aluminum fin Tube Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 650 650 Sound Pressure dB A 51 54 Dimension Net Dim W D H mm 800 300 198 800 300 198 Pack Dim W D H mm 870 370...

Page 31: ...or Model YYK18 4B D 310 30 8 Output Power W 18 30 Speed H M L r min 1250 1330 Indoor Coil Number Of Row 2 2 Tube x Row Pitch mm 20 5x 12 7 20 5x 12 7 Fin Pitch mm 1 4 1 4 Fin Material Hydrophilic aluminum fin Tube Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 650 1000 Sound Pressure dB A 42 48 Dimension Net Dim W D H mm 800 300 198 970 315 235 Pack Dim W D H mm 870 370 282 1047 385...

Page 32: ...utput Power W 12 12 Speed H M L r min 1150 1150 Indoor Coil a Number Of Row 2 2 b Tube Pitch a x Row Pitch b mm 20 5x 12 7 20 5x 12 7 c Fin Pitch mm 1 3 1 3 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 600 600 Sound Pressure Noise Level dB A 51 54 Dimension Net Dimension W D H mm 750 285 200 750 285 200 Packing Dimensi...

Page 33: ...8 Output Power W 12 30 Speed H M L r min 1150 1330 Indoor Coil a Number Of Row 2 2 b Tube Pitch a x Row Pitch b mm 20 5x 12 7 20 5x 12 7 c Fin Pitch mm 1 3 1 4 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 600 850 Sound Pressure Noise Level dB A 42 45 Dimension Net Dimension W D H mm 750 285 200 900 310 225 Packing Dime...

Page 34: ...30 Indoor Coil a Number Of Row 2 b Tube Pitch a x Row Pitch b mm 20 5x 12 7 c Fin Pitch mm 1 4 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved f Coil Length x Height x Width mm 850 41 18 Performance Air Flow Volume m3 h 1150 Sound Pressure Noise Level dB A 49 Dimension Net Dimension W D H mm 1082 330 233 Packing Dimension W D H mm 1155 397 312 Weight Net...

Page 35: ...H M L r min 1150 1150 Indoor Coil a Number Of Row 2 2 b Tube Pitch a x Row Pitch b mm 20 5x 12 7 20 5x 12 7 c Fin Pitch mm 1 3 1 3 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 600 600 Sound Pressure Noise Level dB A 40 38 34 40 38 34 Sound Pressure Noise Level dB A 51 54 Dimension Net Dimension W D H mm 792 292 201 792...

Page 36: ...eed H M L r min 1150 1330 Indoor Coil a Number Of Row 2 2 b Tube Pitch a x Row Pitch b mm 20 5x 12 7 20 5x 12 7 c Fin Pitch mm 1 3 1 4 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved Performance Air Flow Volume m3 h 600 850 Sound Pressure Noise Level dB A 42 40 37 45 42 37 Sound Pressure Noise Level dB A 52 55 Dimension Net Dimension W D H mm 792 292 201...

Page 37: ...ed f Coil Length x Height x Width mm 850 41 18 Performance Air Flow Volume m3 h 1150 Sound Pressure Noise Level dB A 49 43 37 Sound Pressure Noise Level dB A 59 Dimension Net Dimension W D H mm 1132 330 232 Packing Dimension W D H mm 1205 400 317 Weight Net kg 14 Gross kg 17 Refrigerant Type R32 Pipe Diameter Liquid Side 6 35 1 4 6 35 1 4 Gas Side 9 52 3 8 15 88 5 8 Drainage 16 5 16 5 Stuffing Qua...

Page 38: ...hx Row Pitch mm 20 5x 12 7 20 5x 12 7 Fin Pitch mm 1 5 1 5 Fin Material Hydrophilic aluminum fin Hydrophilic aluminum fin Tube Outside Dia Material mm φ7 Inner grooved φ7 Inner grooved Coil Length x Height x Width mm 1320x205x 25 4 1320x205x 25 4 Heat Exchanging Area m2 6 12 6 12 Performanc e Air Flow Volume CFM 412 353 312 412 353 312 m3 h 700 600 530 700 600 530 Sound Pressure Level dB A 45 41 3...

Page 39: ...AUX DC Inverter Free Match 50HZ R32 39 h Gas Side mm inc h 12 7 1 2 12 7 1 2 Drainage mm 20 20 Loading Qty 20 40 40H unit 147 309 348 147 309 348 ...

Page 40: ...Fin Pitch mm 1 5 Fin Material Hydrophilic aluminum fin Tube Outside Dia Material mm φ7 Inner grooved Coil Length x Height x Width mm 1320x205x 25 4 Heat Exchanging Area m2 6 12 Performance Air Flow Volume CFM 412 353 312 m3 h 700 600 530 Sound Pressure Level dB A 45 41 35 Sound Power Level dB A 56 Dimension Net Dim W D H mm 570 570 260 Packing Dim W D H mm 655x655x295 Net Panel mm 650x650x55 Packi...

Page 41: ... Row Pitch b mm 20 5x 12 7 20 5x 12 7 c Fin Pitch mm 1 6 1 6 d Fin Material Hydrophilic aluminum fin Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved φ7 Inner grooved f Coil Length x Height x Width mm 599x246x 38 1 599x246x 38 1 g Heat Exchanging Area m2 6 32 6 32 Performance Air Flow Volume CFM 441 353 294 441 353 294 m3 h 750 600 500 750 600 500 Sound Pressure Noise L...

Page 42: ...e Pitch a x Row Pitch b mm 20 5x 12 7 c Fin Pitch mm 1 6 d Fin Material Hydrophilic aluminum fin e Tube Outside Dia And Material mm φ7 Inner grooved f Coil Length x Height x Width mm 599x246x38 1 g Heat Exchanging Area m2 6 32 Performance Air Flow Volume CFM 500 412 353 m3 h 850 700 600 Sound Pressure Noise Level dB A 45 42 40 Sound Power Noise Level dB A 59 Dimension Net Dimension W D H mm 929 66...

Page 43: ...Pitch mm 20 5x 12 7 20 5x 12 7 Fin Pitch mm 1 4 1 4 Fin Material Hydrophilic aluminum Hydrophilic aluminum Tube Dia Material mm φ7 Inner grooved φ7 Inner grooved Coil L x H x W mm 541x255x 25 4 541x255x 25 4 Heat Exchange Area m2 5 01 5 01 Performance Air Flow Volume CFM 353 265 224 353 265 224 m3 h 600 450 380 600 450 380 Sound Pressure Noise Level dB A 35 31 28 35 31 28 Sound Power Noise Level d...

Page 44: ...tch mm 20 5x 12 7 20 5x 12 7 Fin Pitch mm 1 4 1 4 Fin Material Hydrophilic aluminum Hydrophilic aluminum Tube Dia Material mm φ7 Inner grooved φ7 Inner grooved Coil L x H x W mm 541x255x 25 4 840x255x 25 4 Heat Exchange Area m2 5 01 7 78 Performance Air Flow Volume CFM 400 329 265 506 388 353 m3 h 680 560 450 860 660 600 Sound Pressure Noise Level dB A 38 34 31 42 38 36 Sound Power Noise Level dB ...

Page 45: ...wer KW 2 1 2 3 Performance SEER SCOP W W 6 16 4 06 F 7 07 4 08 F SEER SCOP W W 6 15 4 05 L 7 08 4 06 L SEER SCOP W W 6 16 4 06 J 7 07 4 07 J Energy Rate A A A A EER COP W W 3 31 4 17 3 03 3 64 DC Inv Compressor Model KSN108D22UFZ KSM135D23UFZ Quantity 1 1 Type Rotary Rotary Brand GMCC GMCC Capacity W 3470 4245 Input W 890 1075 Power Supply V Hz Ph 220 240 50 1 220 240 50 1 Rated Current A 6 05 7 1...

Page 46: ...und Pressure Noise Level dB A 54 55 Sound Power Noise Level dB A 61 62 Dimension Net Dimension W D H mm 800 315 545 800 315 545 Packing Dimension W D H mm 920 400 620 920 400 620 Weight Net kg 34 36 Gross kg 37 39 Refrigerant type Quantity Type R32 R32 Charged Volume kg 0 92 0 95 Piping Liquid Side mm inch 2 6 35 1 4 2 6 35 1 4 Gas Side mm inch 2 9 52 3 8 2 9 52 3 8 Max length for all rooms m m 40...

Page 47: ...ER SCOP W W 6 57 4 38 F 6 30 4 04 F SEER SCOP W W 6 45 4 39 L 6 29 4 04 L SEER SCOP W W 6 57 4 39 J 6 30 4 04 J Energy Rate A A A A EER COP W W 3 23 3 71 3 21 3 61 DC Inv Compressor Model KTN150D30UFZ KTM240D57UKP Quantity 1 1 Type Twin Rotary Twin Rotary Brand GMCC GMCC Capacity W 4690 7715 Input W 1250 2085 Power Supply V Hz P h 220 240 50 1 220 240 50 1 Rated Current A 7 1 9 5 Operating Frequen...

Page 48: ... Sound Pressure Noise Level dB A 56 58 Sound Power Noise Level dB A 65 65 Dimension Net Dimension W D H mm 834 328 655 834 328 655 Packing Dimension W D H mm 945 435 725 945 435 725 Weight Net kg 44 46 Gross kg 47 49 Refrigerant type Quantity Type R32 R32 Charged Volume kg 1 1 1 05 Piping Liquid Side mm inc h 3 6 35 1 4 3 6 35 1 4 Gas Side mm inc h 3 9 52 3 8 3 9 52 3 8 Max length for all rooms m ...

Page 49: ...5 24 5 Max power KW 5 3 5 6 Performance SEER SCOP W W 6 10 4 00 F 6 10 4 10 F SEER SCOP W W 6 20 4 00 L 6 10 4 00 L SEER SCOP W W 6 15 4 12 J 6 14 4 14 J Energy Rate A A A A EER COP W W 2 66 3 49 2 70 3 47 Model KTF310D43UMT KTF310D43UMT Quantity 1 1 Type Rotary Rotary Brand GMCC GMCC Capacity W 10010 10010 Input W 2765 2765 Power Supply V Hz Ph 220 240 50 1 220 240 50 1 Rated Current A 5 38 5 38 ...

Page 50: ...3 Air Flow Volume CFM 2353 2471 m3 h 4000 4200 Noise Level Sound Pressure Noise Level dB A 61 61 Sound Power Noise Level dB A 68 68 Dimension Net Dimension W D H mm 985 395 808 985 395 808 Packing Dimension W D H mm 1105 495 895 1105 495 895 Weight Net kg 74 75 Gross kg 78 79 Refrigerant type Quantity Type R32 R32 Charged Volume kg 2 3 2 3 Additional charge g m 20 20 Piping Liquid Side mm inch 4 6...

Page 51: ...ty test Condition 27 DB 19 WB Indoor 35 DB 24 WB Outdoor Heating capacity test Condition 20 DB Indoor 7 DB 6 WB Outdoor Connecting pipe length 7 5M 2 Data may be changed with unit improvement We keep the right to change the data or specifications without prior notice please follow the data listed on the nameplate ...

Page 52: ...315 Width mm 198 198 198 235 Physical Dimension AMWM H07 4R3 F AMWM H09 4R3 F AMWM H12 4R3 F AMWM H18 4R3 F AMWM H24 4R3 F Length mm 750 750 750 900 1082 Height mm 285 285 285 310 330 Width mm 200 200 200 225 233 Physical Dimension AMWM H07 4R3 J AMWM H09 4R3 J AMWM H12 4R3 J AMWM H18 4R3 J AMWM H24 4R3 J Length mm 792 792 792 940 1132 Height mm 292 292 292 316 330 Width mm 201 201 201 224 232 ...

Page 53: ...AUX DC Inverter Free Match 50HZ R32 53 2 Cassette 09K 12K 18K 650 650 290 570 260 570 515 530 463 511 55 650 650 350 ...

Page 54: ...AUX DC Inverter Free Match 50HZ R32 3 Ceiling Floor 09K 12K 18K 929 660 245 841 205 ...

Page 55: ...AUX DC Inverter Free Match 50HZ R32 55 4 Duct 4 1 07K 09K 12K Air Return Air Outlet 470 200 168 383 684 700 734 583 111 Air Return Air Outlet ...

Page 56: ...AUX DC Inverter Free Match 50HZ R32 4 2 18K 832 110 Air Outlet Air Outlet Air Return 383 977 1000 1048 470 200 168 ...

Page 57: ...AUX DC Inverter Free Match 50HZ R32 57 5 Outdoor Unit 5 1 14K 18K 545 800 545 822 315 315 ...

Page 58: ...AUX DC Inverter Free Match 50HZ R32 5 2 21K 27K 834 540 655 854 335 328 ...

Page 59: ...AUX DC Inverter Free Match 50HZ R32 59 5 3 36K 42K 985 675 808 1000 409 395 ...

Page 60: ...part in the frame may not be used DC Fan Motor AC Fan Motor WIFI Module Displayreceivepanel Step Motor Step Motor FUSE 3 15A 250V PCB Forced Switch Transformer Anion High Voltage Generator Electrostatic Duster TemperatureSensor To Outdoor Unit Brow L N PE C Red Blue Y G Black L L0 S N Some models have no content inside dashed frame 16437010000237 Indoor Unit Electric Chart M1 M2 M4 M3 ...

Page 61: ...orced Switch Transformer Anion High Voltage Generator Electrostatic Duster TemperatureSensor To Outdoor Unit Some models have no content inside dashed frame M1 M2 M4 M3 16437010000447 Indoor Unit Electric Chart L N C L N PE C Brow Blue Y G Black NOTE Dotted line part in the frame may not be used DC Fan Motor AC Fan Motor WIFI Module ...

Page 62: ... S must be sufficient for the maximum system current The maximum system current is equal to the sum of indoor unit and outdoor unit rated current if used as MULTI unit Lo on the terminal block does not need to be connected L IN To Outdoor Unit Sensor Temperature Controlling board Step Motor Step Motor Panel Wifi Module AC Fan Motor generator Anion Force Switch Indoor Unit Electric Chart DC Fan Mot...

Page 63: ...aynotbeused PCB CN13 CN8 CN11 CN9 TR 0 TR IN PUMB CN3 CP10 L R AC N AC L1 Step Motor Fan Motor Transformer Water Pumb M2 M1 FloatSwitch RoomTemp CN 7 CN 12 RD BN BU BK Display Board Wired Controller WIFI Module EvapTemp 16437010000317 Power Communication PE L N C S M3 M4 Indoor Unit Electric Chart ...

Page 64: ...AUX DC Inverter Free Match 50HZ R32 3 Ceiling Floor 09k 12k 18k ...

Page 65: ...AUX DC Inverter Free Match 50HZ R32 65 4 Duct 07K 09K 12K 18K ...

Page 66: ...DATA2 Indoor UnitA L N C S L N POWER PE DATA1 DATA3 RD GN means 0 means1 Notes Notes Dotted line part in the frame may not be used M2 DC FAN BN BU BN BU Y G Y G RD BU BK Temperature Sensor Y G L N C S Indoor UnitB Indoor UnitC Metal partition On line test line SW1 SW2 000 00 001 00 010 00 100 00 101 00 011 00 A B A B GN YE Indoor Unit 24K Split unit 18K Split unit 27K Multi split unit 21K Multi sp...

Page 67: ...AUX DC Inverter Free Match 50HZ R32 67 5 1 36K 42K ...

Page 68: ...3 48 52 23 16 1 26 1 19 1 12 1 08 1 05 1 0 95 0 90 0 87 0 85 0 82 0 77 25 18 1 28 1 26 1 19 1 12 1 08 1 05 1 0 95 0 90 0 87 0 85 0 82 27 19 1 30 1 28 1 26 1 19 1 12 1 08 1 05 1 0 95 0 90 0 87 0 85 28 20 1 33 1 30 1 28 1 26 1 19 1 12 1 08 1 05 1 0 95 0 90 0 87 30 22 1 5 1 33 1 30 1 28 1 26 1 19 1 12 1 08 1 05 1 0 95 0 90 32 24 1 7 1 5 1 33 1 30 1 28 1 26 1 19 1 12 1 08 1 05 1 0 95 Actual cooling ca...

Page 69: ...2 1 25 18 0 87 0 93 0 97 1 1 06 1 08 1 1 1 14 1 2 20 0 8 0 87 0 93 0 97 1 1 06 1 08 1 1 1 14 22 0 71 0 8 0 87 0 93 0 97 1 1 06 1 08 1 1 24 0 62 0 71 0 8 0 87 0 93 0 97 1 1 06 1 08 Actual heating capacity calculation Actual heating capacity amendment coefficient of heating capacity nominal heating capacity Rated heating capacity could be found from Part 4 Specification amendment coefficient of heat...

Page 70: ...pipe length is more than this then you should charge more refrigerant into the system according to the above Charging Data 2 The thickness of the pipe is 0 6 1 0 bearing pressure is 4 2MPa 3 If the connection pipe is too long the cooling capacity and stability would be decreased And the more bend quantity the resistance in the piping system would be bigger then the cooling and heating capacity wou...

Page 71: ...ty under different height drop K3 Different Cooling Capacity modified coefficients at different height Note H Height of Outdoor Unit Height of Indoor Unit Different Heating Capacity modified coefficients at different height Note H Height of Outdoor Unit Height of Indoor Unit Height Differenc C Equivalent pipe Height Differenc Equivalent pipe H ...

Page 72: ...Oil Loop m 6 35 0 10 0 7 9 52 0 18 1 3 12 70 0 20 1 5 15 88 0 25 2 0 19 05 0 35 2 4 22 02 0 40 3 0 Equivalent Pipe length L Actual Pipe length L Bend Qty Equivalent pipe bend length Oil Loop Qty Equivalent Oil Loop length Sample ALCA H42 5 Actual Pipe length is 25 meters Gas pipe diameter is 15 88mm If there s 5 bends and 2 oil loops during the installation then the equivalent pipe length should b...

Page 73: ...AUX DC Inverter Free Match 50HZ R32 73 Part8 Static pressure curve 1 07K 09K Duct ...

Page 74: ...AUX DC Inverter Free Match 50HZ R32 2 12K Duct ...

Page 75: ...AUX DC Inverter Free Match 50HZ R32 75 3 18K Duct ...

Page 76: ...er Free Match 50HZ R32 Part9 Controller 1 Controller IDU type Controller Standard Optional Wall Mounted YK H AUX YK K AUX Cassette YK K AUX XK 04 Ceiling Floor YK L AUX XK 04 Duct XK05 DY AUX 120 XK 04 1 1 K series ...

Page 77: ...on 1 Press this button for the first time when operation it will start the up and down swing function Press the button for the second time cancel the swing function SWING button 2 Press this button for the first time when operation it will start the right and left swing function Press the button for the second time cancel the swing function Feeing button Press this button for setting the feeling f...

Page 78: ...en displays all presetting parameters and remains constant after reaching presetting time air conditioner will automatically start as per presetting state After setting timing ON and OFF function pressing button of Timer Clock can cancel timing setting SLEEP button 1 Press the button to the sleeping indicator light of indoor unit flashes on 2 In sleeping mode the cooling operation enables the set ...

Page 79: ...nit ON OFF MODE button Select mode push the button one time then the operation modes will change in turn as Auto Cooling Dehumidify Heating TEMP button and TEMP button Temperature adjustment range 16 32 FAN button Change the fan speed will change in turn as Low Medium High Auto ...

Page 80: ...tting The OFF setting is the same methods Remark When setting functions such as mode temperature air port and air velocity display screen displays all presetting parameters and remains constant after reaching presetting time air conditioner will automatically start as per presetting state After setting timing ON and OFF function pressing button of Timer Clock can cancel timing setting SLEEP button...

Page 81: ...AUX DC Inverter Free Match 50HZ R32 81 ...

Page 82: ...white backlight 4 Display the failure of main controller 5 Ambient temperature detection sensor 6 Receive the signal of wireless remote controller XK 04 Features Technical indicator 1 Power source voltage DC 12V 2 Work temperature range of PCB 0 50 3 Work humidity range of PCB RH20 RH90 4 Button Touch button 5 Dimensions W H D 86 86 10 8mm Main functions 1 9 keytouch button input 2 Buzzer prompt t...

Page 83: ...AUX DC Inverter Free Match 50HZ R32 83 7 Connect to indoor unit via 3 core shielded cable 8 Receive the signal of wireless remote control XK 05 ...

Page 84: ...own the unit 1 1 When the unit is running users can regulate the operation mode fan speed setting temperature special functions and other parameters on the wired controller XK 05 RoomTemp C Set Temp C TIMER FAN SWING MODE FUNCTION ON OFF XK 04 2 When the unit is standby the wire controller displays indoor ambient temperature Room ...

Page 85: ...tton 2 1 When the unit is running press or button to increase or decrease the setting temperature by 1 Under COOL DRY and HEAT modes the setting temperature range is 16 32 The controller will display Set temp to show the setting temperature XK 05 Set Tem p C Set Tem p C Set Tem p C TIMER FAN SWING MODE FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF ...

Page 86: ...ing order AUTO COOL DRY FAN HEAT AUTO The initial setting temperature for each mode is 24 C and there is no temperature setting and automatic wind under FAN mode 4 Fan buttom When the unit is running press Fan button to switch fan speed in the following order Auto Auto Low Medium High Auto Auto Low Medium High Super high 5 Swing button 5 1 For the unit only has the function of up and down swing wh...

Page 87: ... button to regulate the swing angle in the order cancel up and down swing 5 3 For the unit has the functions of left and right swing and up and down swing Press Swing button the swing mode will switch in the following cycle order Up and Down Swing On Up and Down Swing OFF Left and RightSwing On Up and Down Left and RightSwing OFF Left and RightSwing OFF Up and Down Left and RightSwing On 6 Timing ...

Page 88: ...ming time setting interface the default timing time is 0 5H at this moment press or button to regulate the timing time If the button is not pressed for 10 seconds the timing setting will be canceled and then return to the state of non timing XK 05 Time off Room Temp C Time on Set Temp C Time off Room Temp C Time on Set Temp C TIM ER FAN SWING M ODE FUNCTION ON OFF XK 04 ...

Page 89: ...e time bar will stop blinking XK 05 Time off Room Temp C Time on Set Temp C Time off Room Temp C Time on Set Temp C TIM ER FAN SWING M ODE FUNCTION ON OFF XK 04 6 4 After the setting Timer On function you can adjust the fan speed running mode set temperature and swing angle If there is no operation for 10 seconds standby screen will be displayed ...

Page 90: ...O FF TIM ER FAN SWING M O DE FUNCTIO N O N O FF TIM ER FAN SWING M O DE FUNCTIO N O N O FF XK 04 6 5 Timing range 0 5 24 hours press or button once the timing time will increase or decrease by 0 5 hours When the timing time is more than 10 hours press or button once the timing time will increase or decrease by1 hour 6 6 Press Timer button or ON OFF button to exit Timer ON or Timer OFF ...

Page 91: ...n and the corresponding icon will lash press function button again to confirm the function Cancel function Press function button to enter function selection interface press or button to select a function and the corresponding icon will lash press function button again to cancel the function 1 Turbo Turbo function The fan speed will be ultra high in turbo mode and users can achieve rapid cooling or...

Page 92: ...ING MODE FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF XK 04 Cancel turbo function 1 When turbo function is opened press Function button to enter the interface of function selection 2 Press or button to switch to strong function at this moment icon is flashing press Function button to cancel strong function and strong icon would not display XK 05 ...

Page 93: ...Turbo icon and icon do will not display 2 Sleep Sleep function Make indoor unit will run according to pre set sleep temperature curve which creates a comfortable sleep environment and improves sleep quality Enter sleep function 1 In the state of running press Function button to enter the interface of function selection 2 Press or button to switch to sleep function Sleep icon is flashing at this mo...

Page 94: ...FUNCTIO N O N O FF TIM ER FAN SWING M ODE FUNCTION ON OFF XK 04 Cancel sleep function 1 In the state of running press Function button to enter the interface of function selection 2 Press or button to switch to sleep function Sleep icon is flashing 3 Press Function button again to cancel sleep function XK 05 ...

Page 95: ...FF TIM ER FAN SWING M O DE FUNCTIO N O N O FF XK 04 3 ECO Enter ECO function 1 Press Function button to enter the interface of function selection 2 Press or button to switch to ECO function at this moment Eco icon is flashing 3 Press Function button again to confirm ECO function at this moment Eco icon is lighting ...

Page 96: ... FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF XK 04 Cancel ECO function 1 Press Function button to enter the interface of function selection 2 Press or button to switch to ECO function at this moment Eco icon is flashing 3 Press Function button again to cancel ECO function XK 05 ...

Page 97: ...nditioner would automatically dry the moisture in the evaporator of indoor unit so as to avoid mildewing Enter mildew proof function 1 Under COOL and DRY mode press Function button to enter the interface of function selection 2 Press or button to switch to the mildew proof function setting interface at this moment icon is flashing 3 Press Function button again to enter mildew proof function icon i...

Page 98: ... ON OFF XK 04 Cancel fungus proof function 1 When mildew proof function is ON press Function button to enter the interface of function selection 2 Press or button to mildew proof function icon is flashing 3 Press Function button again to cancel mildew proof function icon will disapper XK 05 Set Temp C Eco Sleep Set Temp C TIMER FAN SWING MODE FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF ...

Page 99: ...of running press Function button to enter the interface of function selection 2 Press or button to light sensation function icon is flashing 3 Press Function button again to enter light sensation function at this moment icon is lighting 4 When light sensation function is on if the indoor lamplight is OFF and lasts for 20minutes the unit will automatically enter sleep mode If the indoor lamplight i...

Page 100: ... MODE FUNCTION ON OFF TIMER FAN SWING MODE FUNCTION ON OFF XK 04 Cancel light sensation 1 When light sensation function is on press Function button to enter the interface of function selection 2 Press or button to light sensation function icon is flashing 3 Press Function button again to cancel light sensation function icon will disappear XK 05 ...

Page 101: ...he evaporator automatically which can not only keep air fresh but also reduce the recession of cooling effect Enter clean function 1 In the state of standby press Function button to enter the interface of function selection 2 Press Function button again to confirm clean function at this moment icon Clean is lighting 3 When the unit is performing clean function the wire controller will keep display...

Page 102: ...m T emp C Room T emp C C l ean Room T emp C C l ean TIM ER FAN SWING M O DE FUNCTIO N O N O FF TIM ER FAN SWING M O DE FUNCTIO N O N O FF XK 04 Display prompt function 10 1 WIFI function display If the unit is equipped with a WIFI function module the icon is lighting ...

Page 103: ... function display Filter screen cleaning reminder function The unit can record its running time when reaching the time set by the user it will remind the user to clean the filter screen so as to avoid prolonged cleaning and filter screen blockage which can result in poor heating cooling effect abnormal protection bacterial breeding and other problems When the running time reaches the filter screen...

Page 104: ...te set on the remote controller and displays corresponding working mode 9 Room temperature sensorequipped on the wired controller When the wire controller is equipped with a room temperature sensor and the sensor is not damaged it is default that the ambient temperature detected by the sensoron the controller and the temperature value will be sent to the main PCB of the unit If the wire controller...

Page 105: ...AUX DC Inverter Free Match 50HZ R32 105 Wired controller 1 Power supply voltage DC 12V 2 Work temperature range of PCB 10 70 3 Work humidity range of PCB RH20 RH90 ...

Page 106: ...of room sensor DUCT AMSD H07 4R3A 02 07 01 AMSD H09 4R3A 02 09 01 AMSD H12 4R3A 02 12 01 AMSD H18 4R3A 02 18 01 Ceilling Floor AMCF H09 4R3A 13 09 01 AMCF H12 4R3A 13 12 01 AMCF H18 4R3A 13 18 01 Note 04 Model of IDU 05 Capacity of IDU 15 Selection of air return temperature sensor 00 sensor in indoor unit 01 Sensor in wired controller 2 2 Parameter Setting by YK L Enter the setting interface Make ...

Page 107: ...arameter correspondence Press the MODE button to send order Sent signal to display panels or receivers Then can hearing buzzer once For example If you changed a new PCB to 18K cassette indoor unit then you should set the type of the unit check the above Parameter Setting Items table Mode of IDU is 04 18K cassette paratmeter is 37 Change to 04 Change to 37 then press Mode to confirm ...

Page 108: ... s address can be changed through press the or then press FUNCTION buton to confirm In the timing setting zone HH means seires NO MM means parameter value After Entering into IDU parameter checking via pressing the or buton you can check the parameter value of seires NO 04 05 1 Parameter setting Only in parameter checking model press the FUNCTION button for 5 seconds Enter into parameter setting m...

Page 109: ...atically go back to parameter checking model For example If you want to change the PCB from cassette type to mid duct type for 42k unit you should set the type of the unit check the above Parameter Setting Items table Mode of IDU is 04 42K cassette paratmeter is 11 42K mid duct paratmeter is 39 0411 change to 0439 step1 1 Only in checking model Press FUNCTION for 5S enter parmater checking model 2...

Page 110: ...change to 0439 step2 Press FUNCTION for 5S enter parmater check model Press the or button to get 04 11 Press FUNCTION for 5S again enter parmater setting model After finishing setting press FUNCTION to confirm Press the or button to get 04 39 ...

Page 111: ... standby mode can be controlled by controller The IDU Will be into standby mode can t be controlled by controller How to set the room card function Set method same as the above Part 9 2 2Parameter Setting by YK L or 2 3 Parameter Setting by XK 04 XK 05 For example XK 05 Step 1 Step 2 Press FUNCTION for 5S enter parmater check Press the or button to get 09 39 Press FUNCTION for 5S again enter parma...

Page 112: ...agram When the room card is inserted the air conditioning can be controlled when you leave the room the AC will standby can t be controlled DUCT TYPE and Ceiling Floor after finishing setting press FUNCTION to confirm Press the or button to get 09 01 ...

Page 113: ...edom in APPSTORE and Google store Light Commercial WIFI Module Installation Connect the WIFI module communication wire to WIFI interfaces of main PCB as shown below The WIFI module should be placed in the return air or some other place in WIFI area customers buy the wireless router APP Configuration Press healthy button 8 times consecutive and buzzer even ring two sound then into ...

Page 114: ...to reconnect Turn on the power of the module then repeat the steps above for APP configuration 4 2 AC management Modify AC name and locking function For other instructions please refer to HELP in APP Remote control device Connect the wireless router to internet then open the GPRS It means the remote control device voice control function only effective after connected to the Internet 4 3 Trouble Sh...

Page 115: ...nnected Long press WIFI box 8 seconds to reconfigure the positive button If the problem can t be solved please contact after sales person 4 4 Technical Parameters Working temperature 0 50 Working environment humidity 20 90 RH Dimensions 78 X 52 X 15 5 Configuration cable wire length 1500mm ...

Page 116: ...AUX DC Inverter Free Match 50HZ R32 19 1 2 3 4 5 6 7 9 8 10 12 11 13 15 14 16 18 20 21 23 24 25 27 26 22 17 Part10 Explosive View 1 Wall Mounted 1 1 L Type 07K 09K 12K ...

Page 117: ...ox 1 12 11320079000013 Step motor shaft sleeve 1 13 11230002000058 Step motor 1 14 11321012000005 Controller box sheet metal A 1 15 11222003002779 Main PCB 1 16 11320084000015 Pipe clamp 1 17 11321003000028 Mounting plate assembly 1 18 11320001000216 Chassis 1 19 11320005000386 Volute 1 20 11220551000003 Cross flow fan rubber bearing 1 21 11320080000007 Pubber bearing fixing peg 1 22 1122051300006...

Page 118: ...AUX DC Inverter Free Match 50HZ R32 1 2 L Type 18K 22 23 1 2 3 4 5 8 6 7 11 12 13 14 15 16 17 18 19 20 21 24 1 1 25 9 10 26 ...

Page 119: ... cover 1 10 11320002000311 Medium frame 1 11 11320078000206 Right side cover 1 12 11320065000028 Breakwater 1 13 11222001000112 Remote control 1 14 11224003000602 Evaporator assembly 1 15 11320017000107 Air blade 3 16 11320135000007 Volute 1 17 11220513000058 Cross flow fan assembly 1 18 11230002000071 Step motor 1 19 11320001000191 Chassis 1 20 11221500000028 Mounting plate assembly 1 21 11320084...

Page 120: ...AUX DC Inverter Free Match 50HZ R32 1 3 F Type 07K 09K 12K 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18 19 20 21 14 ...

Page 121: ...e 2 9 11320127000007 Step motor bracket 1 10 11320091000014 Crank link 1 11 11320085000081 Guide vane linkage B 1 12 11320062000028 Bearing fixing bracket 1 13 11224003000649 Evaporator assembly 07 09 1 11224003000764 Evaporator assembly 12 14 11220513000065 Scroll fan 1 15 11320052000044 Fan motor cover 1 16 11230002000068 IDU fan motor 1 17 11221500000034 Mounting plate assembly 1 18 11320084000...

Page 122: ...AUX DC Inverter Free Match 50HZ R32 5 3 2 1 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...

Page 123: ...ing assembly 1 8 11220500000213 Chassis assembly 1 9 11220508000140 Filter 2 10 11320002000303 Medium frame 1 11 11320096000104 Screw cover 1 12 11320003002947 Decorate panel 1 13 11320080000007 Air guiding door fixing pin 1 14 11320005000379 Air louver Horizontal 1 15 11222014000608 Display board 1 16 11320076000057 Medium frame wiring cover 1 17 11328001000350 Base EPS B 1 18 11328001000351 Base...

Page 124: ...AUX DC Inverter Free Match 50HZ R32 1 5 F Type 24K 7 9 20 19 1 2 3 4 5 6 8 10 11 12 13 14 16 17 18 15 ...

Page 125: ...um frame 1 8 11320017000110 left right swing blade 3 9 11320135000008 air louver 1 10 11320079000016 step motor shaft sleeve 1 11 11230002000071 air louver step motor 1 12 11320001000194 chassis 1 13 11220551000003 bearing assembly 1 14 11224003000820 Evaporator assembly 1 15 11220513000059 cross flow fan 1 16 11320052000035 motor cover 1 17 11230003000136 IDU fan motor 1 18 11222003002794 Main co...

Page 126: ...rter Free Match 50HZ R32 1 6 J Type 07K 09K 12K 6 5 7 24 25 26 1 8 19 6 13 3 27 28 2 3 4 9 1 9 2 9 3 9 4 9 5 9 6 9 10 12 13 2 13 1 14 15 16 17 19 1 19 2 19 19 3 19 4 19 5 19 7 20 21 22 23 9 7 18 9 9 9 10 13 11 9 8 ...

Page 127: ...079000016 1 9 5 曲柄 Crank 11320091000014 1 9 6 导风连杆 B Connecting rod B 11320085000081 1 9 7 底座 Chassis 11320001000268 1 9 8 橡皮水塞 Drain jam 11333003000009 1 9 9 轴套 Axle sleeve 11320079000016 1 9 10 步进电机 Step motor 11230002000086 1 10 轴承组合件 Bearing assembly 11220551000003 1 11 轴承固定座 Bearing mounting block 11320062000028 1 12 贯流风叶组件 Streamer blade assembly 11220513000065 1 13 蒸发器总成 Evaporator assembly...

Page 128: ...old the power cord 11320049000007 1 19 7 端子板 Terminal board 11330037000136 1 20 电控盒盖 Control box cover 11320058000067 1 21 电控盒盖屏蔽盖 Electrical control box cover shield cover 11321020000035 1 22 电控盒护板 Electric control box protector 11320111000005 1 23 电控盒护盖 Electric control box cover 11321020000036 1 24 中框接线盖 Medium frame wiring cover 11320076000103 1 25 USB WiFi USB WiFi 11222062000021 1 26 螺钉盖 Scr...

Page 129: ...AUX DC Inverter Free Match 50HZ R32 129 1 7 J Type 18K 20 21 43 44 5 6 7 8 12 13 14 17 23 22 1918 24 25 27 28 9 10 11 15 16 39 29 30 31 32 33 34 35 36 37 1 38 2 3 4 41 40 42 26 ...

Page 130: ...wn wind step motor 11320079000016 12 左右摆风电机座 Swing the wind turbine seat left and right 11320127000007 1 13 过滤网 Filter 11220508000147 2 14 曲柄 Crank 11320091000014 1 15 导风连杆 Ventilation connecting rod 11320085000081 1 16 中框 Medium frame 11320002000291 1 17 左端盖 Left cover 11320078000157 1 18 右端盖 Right cover 11320078000158 1 19 中框装饰板 Medium frame panel 11320088000037 1 20 螺钉盖 Screw cover 113200960001...

Page 131: ... 11320010000045 1 34 抱攀 Hold climbing 11320049000007 1 35 变压器 Transformer 11329009000022 1 36 电控盒 Controller box 11320057000083 1 37 主控板 Main PCB 11222009003609 1 38 电控盒屏蔽板 A Electric control box shielding panel A 11321020000040 1 39 电控盒屏蔽板 B Electric control box shielding panel B 11321020000041 1 40 步进电机 Step motor 11230002000152 1 41 管路压攀 Pipe clamp 11320084000014 1 42 蜗舌 Volute 11320135000024 1...

Page 132: ... Inverter Free Match 50HZ R32 1 8 J Type 24K 30 13 1 13 4 13 3 9 13 22 27 26 10 13 2 3 1 2 7 9 1 9 2 9 3 12 14 16 17 24 21 23 18 2 8 8 1 8 2 8 3 13 5 6 4 5 18 3 18 1 18 4 18 6 18 7 19 25 20 18 5 18 8 18 11 15 ...

Page 133: ... 1 9 蒸发器总成 Evaporator assembly 11224003000820 1 9 1 蒸发器左支架 Evaporator left side carriage 11320015000123 1 9 2 蒸发器部件 Evaporator assembly 11224009000214 1 9 2 蒸发器部件 Evaporator assembly 11224009000213 1 9 3 蒸发器护套 Evaporator protecting bush 11320101000018 1 10 轴承固定座 Bearing fixed chassis 11320062000026 1 11 轴承组合件 Bearing assembly 11220551000003 1 12 贯流风叶 Cross flow fan 11220513000059 1 13 底座组件 Chassis...

Page 134: ... 18 5 温度传感器 Temperature sensor 11329013000103 1 18 6 端子板 Terminal board 11330037000136 1 18 7 电源线抱攀 Hold the power cord 11320049000007 1 18 8 温度传感器 Temperature sensor 11329013000103 1 19 电源连接线压线板 Power wire cable clamp 11320010000045 1 20 负离子发生器 Negative ion generator 11330016000018 1 21 室内电机 IDU fan motor 11230003000136 1 22 电机座 Motor base 11320127000009 1 23 电机压板 Motor holder 11320087000030 1 24...

Page 135: ...AUX DC Inverter Free Match 50HZ R32 135 2 Cassette 09K 12K 18K ...

Page 136: ...bly 16321005000024 1 3 电控盒 electric control box C 16421038000328 1 4 导风圈 Guide solar or lunar halo ABS FR 16420004000008 1 5 接水盘 drain pan 16320005000039 1 6 过线夹 clamp 16420021000010 1 7 风轮 wind wheel 16444001000037 1 8 压线板 pressing line plate 16421008000022 1 9 电机 Fan motor 16430001000638 1 10 蒸发器总成 Evaporator assembly 09 12 16324005000087 1 蒸发器总成 Evaporator assembly 18 16324005000081 1 11 排水泵 dr...

Page 137: ...AUX DC Inverter Free Match 50HZ R32 137 3 Ceiling Floor 09K 12K 18K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 28 29 30 31 32 33 34 26 ...

Page 138: ... 15 顶盖板 Top cover plate 16420014000016 1 16 顶泡沫 Top Foam 16428001000088 1 17 导风架 Holder support 16420006000007 1 18 步进电机 Motor Assembly 16430001000604 1 19 步进电机 Motor Assembly 16430031000001 1 20 垂直叶片连杆 A Vertical vame connecting rod 16420008000003 1 21 垂直叶片 Vertical blade 16420007000008 9 22 右侧板组件 Right side plate assembly 16321006000006 1 23 右挂架 Right pylons 16421001000030 1 24 右盖板 Right cover p...

Page 139: ...AUX DC Inverter Free Match 50HZ R32 139 4 Duct 4 1 07K 09K 12K ...

Page 140: ...2 8 上蜗壳 Upper spiral case 16444002000022 2 9 过滤网框架 Filter framework 16444013000125 1 10 过滤网 Filter net 16444013000125 1 11 挂耳 hangers 16421040000058 4 12 接水盘组件 Drain pan 16320009000026 1 13 电控盒 electric control box 16421038000358 1 14 R 电解电容 Capacitor 11329003000022 1 15 控制板 PCB 11222541000051 1 16 电控盒盖 Electric cover plate 16421042000006 1 17 顶盖板 Top cover plate 16421005000616 1 18 左侧板 Left side ...

Page 141: ...AUX DC Inverter Free Match 50HZ R32 141 4 2 18K ...

Page 142: ...3 8 上蜗壳 Upper spiral case 16444002000022 3 9 过滤网框架 Filter framework 16321009000335 2 10 过滤网 Filter net 16444013000126 1 11 挂耳 hangers 16421040000058 4 12 接水盘组件 Drain pan 16320009000028 1 13 电控盒 electric control box 16421038000358 1 14 R 电解电容 Capacitor 11329003000022 1 15 控制板 PCB 11222541000051 1 16 电控盒盖 Electric cover plate 16421042000006 1 17 顶盖板 Top cover plate 16421005000617 1 18 左侧板 Left side ...

Page 143: ...AUX DC Inverter Free Match 50HZ R32 143 5 Outdoor Unit 5 1 14K 18K ...

Page 144: ... 11222550000016 1 8 顶盖板 Top cover 11321009000057 1 9 四通阀 4 way valve asm 14 16325002000669 1 4 way valve asm 18 16325002000665 1 10 右侧板 Right side panel 16421001000757 1 11 端子盖 Electrical cover 11320068000009 1 12 阀盖板 Check valve cover 16420014000039 1 13 电子膨胀阀 E expensivevalve body 16441014000030 2 14 背侧板 Back side panel 16421001000758 1 15 压缩机 Compressor 14 16438004000119 1 Compressor 18 1122300...

Page 145: ...AUX DC Inverter Free Match 50HZ R32 145 ...

Page 146: ...000017 1 8 顶盖板 Top cover 11321009000052 1 9 四通阀 4 way valve asm 21 16325020000020 1 4 way valve asm 27 16325002000663 1 10 右侧板 Right side panel 16421001000739 1 11 端子盖 Electrical cover 11320068000006 1 12 阀盖板 Check valve cover 16420014000034 1 13 电子膨胀阀 E expensive valve body 16441014000030 3 14 后背板 Back side panel 16421001000753 1 15 压缩机 Compressor 21 16438004000120 1 Compressor 27 16438003000044 ...

Page 147: ...AUX DC Inverter Free Match 50HZ R32 147 5 3 36K ...

Page 148: ...nel 11321005000100 1 11 面板网罩 Plastic grille 11320026000057 1 12 大面板 Big Front panel 11321005000099 1 13 左侧板 Left side panel 11321156000010 1 14 顶盖板 Top cover 11321009000054 1 15 隔风立板 Separate panel 11321025000074 1 16 顶盖板海绵 sponge 11327014000063 1 17 轴流风叶 Fan blade 11320009000061 1 18 直流电机 Fan motor 16430033000043 1 19 电机架 Motor bracket 11321002000038 1 20 电抗器 Reactor 11330034000012 2 21 回气管组件 Gas...

Page 149: ...AUX DC Inverter Free Match 50HZ R32 149 5 4 42K ...

Page 150: ...11321005000100 1 11 面板网罩 Plastic grille 11320026000057 1 12 大面板 Big Front panel 11321005000099 1 13 左侧板 Left side panel 11321156000010 1 14 顶盖板 Top cover 11321009000054 1 15 隔风立板 Separate panel 11321025000074 1 16 顶盖板海绵 Sponge 11327014000063 1 17 轴流风叶 Fan blade 11320009000061 1 18 直流电机 Fan motor 16430033000043 1 19 电机架 Motor bracket 11321002000038 1 20 电抗器 Reactor 11330034000012 2 21 回气管组件 Gas pip...

Page 151: ... cable electrical wire between indoor and outdoor unit Must be in accordance with the wire diameter in the wiring diagram Acetylene cylinders oxygen cylinders when longer pipe used it should be welded One set pipe cut machine cut copper pipe Refrigerant cans electronic balance when longer pipe used additional gas should be charged Pressure gauges pipe clamp welding torch 2B silver electrode Wrench...

Page 152: ...drainage The unit should not be installed in the heat source steam or oil mist source such as machine room kitchen laundry room mechanical workshop etc Choose the location at least 1 meter away from TV and radio in order to avoid interference to them There should be certain distance between indoor unit and obstacles for maintence In case of leakage of refrigerant units should immediately stop runn...

Page 153: ...ly incline downwards Hang indoor unit on hanging plate and move the unit to left or right to ensure hanging hook is correctly positioned on the hanging plate 3 3 Installation of Sterilization Net Uplift panel of indoor unit pull out the bulge in the middle of air filter downwards after uplifting Completely snap sterilization net inside accessory bag into sterilization mounting support on air filte...

Page 154: ... two screw caps on both sides of the front grille and then screw down two fixing screws Pull the lower end of grille cover towards oneself to remove it Reinstall grille cover then install the grille cover to proper position according to the reverse sequence of the above Pour a glass of water into plastic drainage groove Confirm if the water flows through the drainage outlet of indoor unit ...

Page 155: ...AUX DC Inverter Free Match 50HZ R32 155 4 Cassette 4 1 Installation drawing ...

Page 156: ...oundation The suspension foundation is a structure of either wooden frame or reinforced concrete It must be firm and reliable to bear at least 4 times weight of itself and capable of bearing vibration for long periods Fixing of suspension foundation Fix the suspension bolts either as shown in the picture or by a steel or wooden bracket ...

Page 157: ...the suspension bolt so that the unit can be in level position in all directions Check with a level gauge after installation to ensure that the indoor unit is horizontal otherwise it will cause water leakage air leakage etc Tighten the bolt and ensure that four hooks are in close contact with the nuts and washers to fix the indoor unit under the ceiling After the unit is installed ensure it is secu...

Page 158: ...hickness of rubber insulation pipe should be more than 8mm Drainage pipe must have a downward gradient 1 50 1 100 to avoid water backflow or leakage etc The unit has a drain pump which will lift up to 700 mm However after the pump stops the water left in the pipe will drain back and may overflow the drain tray causing water leakage For this reason please install the drain pipe as shown ...

Page 159: ...ion to ensure that there is no water leakage If the unit is installed in the newly built house strongly recommend that this test taken before the ceiling installation Even it is the heating only unit this test is unavoidable 4 5 Panel installation As to the MB13 panel please refer to the following picture the panel has four hooks which attach to corresponding hangers on the unit and the panel shou...

Page 160: ...AUX DC Inverter Free Match 50HZ R32 ...

Page 161: ...ght of itself and capable of bearing vibration for long periods Fixing of suspension foundation Fix the suspension bolts either as shown in the picture or by a steel or wooden bracket Adjust the relative position of the suspension hook on the suspension bolt so that the unit can be in level position in all directions Check with a level gauge after the installation is complete in order to ensure th...

Page 162: ...re it is secure and does not shake or sway 5 3 Drainage pipe The drainage pipe should be properly insulated to prevent the generation of condensation Heat insulation material the thickness of rubber insulation pipe should be more than 8mm Drainage pipe must have a downward gradient 1 50 1 100 T avoid water backflow or leakage etc When finish installation please carry out the drainage test to ensur...

Page 163: ...and carefully observe the junction to ensure that there is no water leakage at the junction If the unit is installed in the newly built house strongly recommend that this test taken before the CFiling installation Even it is the heating only unit this test is unavoidable ...

Page 164: ...sening would lead to air conditioner falling and so on As shown the indoor unit should be leaning to the drain hole to be convenient for drainage H Air Outlet Air Return Air Outlet I G C D Air Return A B E F Model A mm B mm C mm D mm E mm F mm G mm H mm I mm 07K 09K 12K 583 700 684 734 383 470 168 110 200 18K 832 1000 977 1048 383 470 168 110 200 ...

Page 165: ...water outlet and the drainage pipe respectively then fix with a hoop as shown in Fig1 b Wrap the heat insulation cotton on the drain insulation pipe and the hoop as shown in Fig 2 c Tighten the sponge with a bandage as shown in Fig3 The drain pipe must have a downward gradient 1 50 1 100 If the drain pipe is installed ups and downs or upward it will lead to water back flow or leakage etc During pi...

Page 166: ...de of indoor unit unused drain pipe must be closed Note The drain pipe must be wrapped heat insulation material otherwise it will cause condensation or water drops Heat insulation material rubber insulation pipe with thickness more than 8mm 6 5 wired control connection ...

Page 167: ...that the outlet is not facing the strong wind The site shall be ensured that outlet air and operation noise will not affect the neighbors daily life The site shall be ensured that the outdoor unit will not be affected by the garbage and oil mist Warning If outdoor unit working under such environment which contains oil including machine oil salt marine areas sulfide gas hot springs and oil refinery...

Page 168: ... wind please fasten it as tightly as possible Set a drainage channel to ensure the condensing water can drain out smoothly Avoid that only four angles metal sheet to support the outdoor unit Transport When the outdoor unit is to be lifted please use two slings longer than 8m and insert cushioning material between the slings and outdoor unit to avoid damaging the casing 8 Connection piping installa...

Page 169: ...n gas or air to remove the dust and water in the pipe Please lay out the piping according to the tend towards of the piping but it is not allowed more than 3 times curved at the same point of the pipe if do like this the pipe will become rigid When using pipe bending machine the curvature shall not be too small or it will affect the refrigerant flow ...

Page 170: ...m 62 76 N m 18 6 19 0mm 3 4in φ19 05mm 70 75 N m 22 9 23 3mm 8 3 Piping connection Using expanding machine to expand accessories the size of horn shown in the above figure Paint a thin layer of frozen oil at both inside and outside part of the expanding Make the expanding right to the screw thread shape connection of the indoor unit using hands to tighten the nut then using a wrench to tighten the...

Page 171: ...5 bends and 2 oil loops during the installation then the equivalent pipe length should be L 25 0 18 5 1 3 2 28 5 m 9 Emptying or vacuum Before charging the refrigerant to the system to ensure that there is no impurities water or non condensable gas So emptying and vacuum operation should be carried out Vacuum when process this operation please be sure that the connection pipe is tightened up 1 Scr...

Page 172: ... outlet air becomes mist it feels cold by touching it then the air is emptied 3 When ensure that the air is emptied connect and tighten the high pressure valve of outdoor unit stop valve and liquid side connection pipe keep this state more than 10 seconds 4 Use soapy what to test each connection junctions including lengthen piping welding junction 5 Confirmed that there is no leakage turn off the ...

Page 173: ...AUX DC Inverter Free Match 50HZ R32 173 10 Insulation Use heat insulation material with good insulation performance to wrap the pipe ...

Page 174: ... back side of ceiling should pasted with insulation material Besides the previous more than 8mm thick insulation material connection piping both gas pipe and liquid pipe drainage pipe should be wrapped by additional 10 30 mm thick insulation material Seal the hole on the wall To prevent rainwater or other foreign bodies from entering the room and air conditioner the gap between wall hole and tubin...

Page 175: ... Gas pipe Liquid pipe Piping between indoor and outdoor unit φ9 52 0 75mm φ6 35 0 75mm 0 02 φ12 7 1mm φ6 35 0 75mm 0 02 φ15 88 1mm φ9 52 0 75mm 0 050 φ19 05 1mm φ9 52 0 75mm 0 070 φ19 05 1mm φ12 7 1mm 0 090 Note This chart is for explanation purposes An actual installation will differ from this according to the site conditions When making an oil loop the radius of the bend should be between 1 5 an...

Page 176: ...tection devices power supply on off switch and breaker must be required with The specification of fuse for single phase control board is F5AL 250V while for 3 phase control board both indoor and outdoor unit it is F3 15AL 250V Machine must be earthed surely or it ll be probably cause creep age Notice The earth line is neither allowed to connect to gas pipe water pipe circuitry of telephone or ligh...

Page 177: ...be grounded Each indoor unit must be grounded Power wire must be thickened when it is overlong Wiring Diagram of Modular Outdoor Unit The wiring cable specification that is needed in the installation Wire Type ODU Power supply Indoor power cable Power line 3 core line 14k 18k 21k 27k 220 240V 50Hz 3 2 5mm2 36k 42k 3 4mm2 Connection wire 4 core line All IDU 4 1 5mm2 ...

Page 178: ...r electrician All of the ceiling floor type unit is without accessorial electric heating Commissioning The system should be power on for 8 hours for preheat before the first time start up During winter while after 8 hours power off the performance test should be 2 and half hours power on later Power on the system and start up r cooling mode After 3 minutes compressor protection check whether there...

Page 179: ...UX DC Inverter Free Match 50HZ R32 179 After confirmation of normal working condition press the on off button to stop the system At last train the end users with operation maintaining and special notice ...

Page 180: ...AUX DC Inverter Free Match 50HZ R32 Part12 PCB Instruction 1 Outdoor Unit PCB 1 1 14K 18K Main PCB and Driver modular ...

Page 181: ...AUX DC Inverter Free Match 50HZ R32 181 1 2 21K 27K Main PCB and Driver modular ...

Page 182: ...AUX DC Inverter Free Match 50HZ R32 1 3 36K 42K Main PCB ...

Page 183: ...AUX DC Inverter Free Match 50HZ R32 183 Drive Modular Board ...

Page 184: ...AUX DC Inverter Free Match 50HZ R32 2 Indoor Unit PCB 2 1 09K 12K 18K Cassette ...

Page 185: ...AUX DC Inverter Free Match 50HZ R32 185 2 2 09K 12K 18K Ceilling Floor ...

Page 186: ...AUX DC Inverter Free Match 50HZ R32 2 3 07k 09K 12K 18K Duct ...

Page 187: ...tion error between the outdoor unit and the indoor unit 9 E8 E8 Communication error between the display board and PCB of the indoor unit 10 F0 F0 Fault with the Fan motor of outdoor unit 11 F1 F1 Fault with the inverter module protection on the outdoor unit 12 F3 F3 Fault with the compressor start 13 F4 F4 fault with the discharge temperature sensor 14 F6 F6 Fault with the Envirol temperature sens...

Page 188: ...the low pressure 23 H8 H8 fault of four way valve 24 P2 J2 fault with the High pressure switch 25 P5 J5 Protection high temperature discharge 26 P6 J6 Fault with anti high temperature protection of indoor unit in heating model 27 P7 J7 Fault with anti Frozen protection of indoor unit in heating model ...

Page 189: ...AUX DC Inverter Free Match 50HZ R32 189 2 Failure analysis 2 1 H2 Wired controller communication failure ...

Page 190: ...AUX DC Inverter Free Match 50HZ R32 2 2 E5 Communication failure between indoor and outdoor unit ...

Page 191: ...AUX DC Inverter Free Match 50HZ R32 191 Outdoor protection phase sequence ...

Page 192: ...AUX DC Inverter Free Match 50HZ R32 2 3 P2 high pressure protection Cooling high pressure protection Heating high pressure protection ...

Page 193: ...AUX DC Inverter Free Match 50HZ R32 193 2 4 H6 low pressure protection ...

Page 194: ...AUX DC Inverter Free Match 50HZ R32 Cooling low pressure protection Heating low pressure protection ...

Page 195: ...AUX DC Inverter Free Match 50HZ R32 195 2 5 P5 High exhaust temperature protection ...

Page 196: ...AUX DC Inverter Free Match 50HZ R32 Cooling exhaust temperature protection ...

Page 197: ...AUX DC Inverter Free Match 50HZ R32 197 Heating exhaust temperature protection ...

Page 198: ...AUX DC Inverter Free Match 50HZ R32 2 6 H8 four way valve failure protection ...

Page 199: ...AUX DC Inverter Free Match 50HZ R32 199 2 7 Sensor failure protection ...

Page 200: ...KΕΝΤΡΙΚΑ ΓΡΑΦΕΙΑ Λ ΑΘΗΝΩΝ 50 ΣΠ ΠΑΤΣΗ 8 10441 ΑΘΗΝΑ ΤΗΛ ΚΕΝΤΡΟ 210 5288888 FAX 210 5221261 SERVICE 210 5288832 4 ΑΓΗΝΩΡ A E ΟΜΙΛΟΣ ΕΤΑΙΡΙΩΝ ΤΟΥΡΝΙΚΙΩΤΗ ΓΕΝΙΚΟΙ ΑΝΤΙΠΡΟΣΩΠΟΙ ...

Reviews: