●  Use of this equipment adjacent to or stacked 

with other equipment should be avoided 
because it could result in improper operation. If 
such use is necessary, this equipment and the 
other equipment should be observed to verify 
that they are operating normally.

        DANGER:

NEVER APPLY THE PADS TO THESE BODY 
AREAS:

●  The head, the mouth, or any area of the 

face.

●  The neck or any area of the throat because 

this could cause severe muscle spasms 
resulting in closure of the airway, difficulty in 
breathing, or adverse effects on heart rhythm or 
blood pressure.

●  Do not use it near the heart, or on genital 

area.

●  Both sides of the thorax simultaneously 

(lateral or front and back), or across your chest 
because the introduction of electrical current 
may cause rhythm disturbances which could be 
lethal.

●  On the calves of both legs or across the left 

Summary of Contents for TU2124-A

Page 1: ...Please read the product introduction carefully before using the product USER MANUAL Model TU2124 A TENS and Powered Muscle Stimulator Device Name TENS and Powered Muscle Stimulator ...

Page 2: ...ngs 3 Danger 5 Notice 6 Contraindication 10 2 ILLUSTRATIONS OF THE DEVICE AND ACCESSORIE 12 Mode descriptions 14 Operating procedure 18 3 PLACEMENT OF ELECTRODES 21 4 TROUBLESHOOTING 23 5 CLEAN AND MAINTENANCE 27 6 DISPOSAL METHOD 28 7 SYMBOLS 29 8 CUSTOMER SERVIC 29 TABLE OF CONTENTS ...

Page 3: ...neous Transcutaneous Electrical Nerve Stimulations TENS are safe non invasive drug free methods of pain management TENS is currently one of the most commonly used forms of electro analgesia The TENS device relieves pain by sending small electrical impulses through electrodes placed on the skin to underlying nerve fibers EMS Electrical Muscle Stimulation also known as powered muscle stimulator PMS ...

Page 4: ...n Lower extremities leg pain caused by normal household work activities EMS Improve or facilitate muscle performance STANDARD PACKAGE TENS and Powered Muscle Stimulator 1 pcs Pads 1 set Set of Lead Wires 1 set USB Cable 1 pcs User Manual 1 pcs Clip 1pcs FEATURES 20 intensity levels 20 minute default timer adjustable from 10 90 minutes or continuously Rechargeable lithium battery 2 outputs with 24 ...

Page 5: ...your unit inspect these things 1 Cord is not broken 2 Pad gel is not damaged 3 Electrode cord connection is not broken 4 Unit is intact and working 5 There is no battery leakage DO NOT USE UNDER THE FOLLOWING CONDITIONS Pregnant women Do not use it on children or infants because the device has not been evaluated for pediatric use Keep out of the reach of young children because the electrode cord c...

Page 6: ...f stimulation is applied over the menstruating uterus Use of accessories and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation Portable RF communications equipment including peripherals such as antenna cables and external ant...

Page 7: ... The head the mouth or any area of the face The neck or any area of the throat because this could cause severe muscle spasms resulting in closure of the airway difficulty in breathing or adverse effects on heart rhythm or blood pressure Do not use it near the heart or on genital area Both sides of the thorax simultaneously lateral or front and back or across your chest because the introduction of ...

Page 8: ...gh frequency surgical ME EQUIPMENT simultaneously Such use may result in burns and possible damage to the device Operation in close proximity e g 1m to a shortwave or microwave the ME EQUIPMENT may produce instability in the device output The application of electrodes near the thorax may increase the risk of cardiac fibrillation NOTICE Caution should be used in the presence of the following When t...

Page 9: ...be conducted under the guidance of the prescribing practitioner Do not attempt to move the electrode pads while the device is ON or operating Any electrodes that have current densities exceeding 2mA cm2 may require special attention of the operator Do not use the device around the heart on the head mouth genitals or blemished skin areas on the front of the neck or from electrodes placed on the che...

Page 10: ...onsult with your physician before using this unit If your pain does not improve and becomes serious chronic or severe stop using the unit and consult with your physician The mere existence of pain functions as a very important warning telling us that something is wrong Therefore if you suffer from any serious illness consult your physician in order to confirm that it is advisable for you to use th...

Page 11: ... at the same time Make sure the components are connected well and the pads are fixed on the part of the body you wish to treat or the therapy may not be effective Pad should not touch any metal object such as a belt buckle necklace or other metal worn under clothing Do not overlap pads or put pads on top of each other It may weaken or stop therapy or the unit may stop working Gel pads may also sti...

Page 12: ...ded Always place clean pads in accordance with illustrations provided Do not apply ointment or any solvent to the pads or to your skin because it will disrupt the pads from functioning properly The self adhesive pads will adhere to your skin Do not use it when the colloid attached to pads becomes less or dry CONTRAINDICATION Heart disease Malignant tumor Infectious disease High fever Abnormal bloo...

Page 13: ...omen Patients wearing metal built in devices such as cardiac pacemakers Acute suppurative inflammation site Skin damage or abnormal parts Around the heart around the head Near carotid artery Near the eye Limb bone and joint contracture deformity Abnormal nerve stress Any condition requiring the active supervision of a physician ...

Page 14: ...12 2 ILLUSTRATIONS OF THE DEVICE AND ACCESSORIES 1 3 2 4 12 13 5 6 7 9 10 11 14 8 ...

Page 15: ...ensity indicator Master mode selection button lock button Intensity decrease button Time selection button Two output ports Mode number indicator Lock indicator Battery indicator Intensity increase button On Off switch button Sub mode selection button USB port ...

Page 16: ...ortable tingling P5 Comfortable and slow tingling firstly then the frequency is significantly increased and it becomes a noticeable tingling sensation P6 Low frequency beating with a slight tingling sensation P7 Low frequency slight beating firstly and then continuous comfortable tingling P8 Low frequency slight beating firstly and then comfortable pulsing sensation MODE DESCRIPTION ...

Page 17: ...ariable comfortable tingling slight beating and scrapeing sensation P12 Comfortable slight tingling from shallow to deep with 3 4 seconds pause P13 Comfortable tingling and pulsing sensation from shallow to more deep with 3 4 seconds pause P14 Rhythmic continuous beating P15 Rhythmic scrapeing sensation P16 Quick slight beating first then comfortable tingling ...

Page 18: ...16 EMS P17 Low frequency slight beating P18 Low frequency beating P19 Beating from low frequency to a little high frequency P20 Muscle twitches at a very low frequency It feels like a tapping massage ...

Page 19: ...il you get a strong but comfortable muscle movement P23 This program uses a pulse frequency appropriate to fast twitching muscle fibers It improves their anaerobic capacity and is used for improving maximum muscle strength P24 This program gently warms up the muscles prior to exercise it feels like a rhythmic beating and comfortable tingling Increase intensity until you get a strong but comfortabl...

Page 20: ...ne pair or two pairs of the electrode pads to the massager area such as the shoulder and leg Note If the stickiness is not good enough after a period of use please try to add a few drops of water on the pads and dry the pads naturally It can increase their longevity Make sure both pads on the skin do not overlap 3 Connect a pair of electrode pads to one lead wire and the other end of the wire shou...

Page 21: ... will turn off until the time finishes Note When the time is set in continuous mode and the channel has output the massage mode will continue to cycle until the battery is exhausted unless it is manually turned off If the channel has no output and no operation the machine will automatically shut down within 5 minutes 9 Press and hold the button for 3 seconds to lock unlock the screen Once the mach...

Page 22: ...NG THE BATTERY 1 Turn off the controller 2 Connect the controller and the charger not included with a USB extension cord Plug the charger not included into any power outlet The charging process will last approximately 3 4 hours Note 1 Only charge the controller when the battery is completely drained the first 2 times Do not use the controller when charging 2 Unplug the charger not included from th...

Page 23: ...ch the pads per illustration on the right on the other side of ypur ankle foot KNEE Modes 1 3 7 8 11 14 17 21 Attach both pads above the knee or above and below oint with pain CALF Modes 1 2 3 4 7 8 9 10 11 14 17 18 19 21 22 23 24 Attach both pads on the calf leg where you feel pain Do not place electrode pads simultaneously to the calves of both legs ...

Page 24: ... Modes 1 4 6 10 12 14 16 24 SCIATIC Modes 1 3 4 5 6 11 14 17 21 23 UPPER ARM THIGH Modes 1 5 6 24 Attach both pads on either side of the area with pain DELTOID Modes 2 3 4 11 14 17 22 Attach one pad in front and one in front and one in back of the muscle ...

Page 25: ...s dirty or dry Wash adhesive the surface of pads gently with your fingertips for about 3 seconds under slow running water The therapy time is too long or the intensity is set too high Reduce the application time or reduce the intensity The electrode pad surface is worn out Replace electrode pad 4 TROUBLESHOOTING If your device works improperly please check below for common problems and the corresp...

Page 26: ...the pads Peel off film on the adhesive surface of pads The pads stack together or overlap Do not stick pads together or overlap pads The cord is not properly connected to the unit Connect cord correctly into the jack The intensity of the setting is getting weak Increase the intensity level The battery capacity is low Charge the battery No power source no display on LCD The battery is drained Charg...

Page 27: ...e adhesive surface of pads Apply the pads immediately after cleaning them Dry the pad The adhesive on the surface of the pad is damaged Replace the pad Power cuts off during use The battery is weak Charge the battery The cord is broken Replace the cord Could not turn on the device The unit is charging Stop charging the unit and try to turn it again ...

Page 28: ...ended that for each increase in the intensity level feel for 1 2 minutes and then slowly increase the intensity per the situation 2 Each mode is different If the frequency or intensity of the mode increases significantly from a lower level during the middle or later stages of the massage further increases in Problem Possible Cause Solution Adhesive on the surface of pads is not sticky Pads get det...

Page 29: ...pe it again with a dry cloth Note 1 The host device shouldn t get wet to avoid damaging the device or reducing the safety and performance of the device 2 Please do not clean or maintain the device when it is working 3 The host device should be cleaned with a soft cloth dampened with a small amount of water at least once a month Maintenance l When you ve finished using the device turn it off and ta...

Page 30: ...6 DISPOSAL METHOD 1 Please do not open the device enclosure only the personnel authorized by the manufacturer can maintain it 2 When the accessories of the device are damaged or fail only the personnel authorized by the manufacturer can replace the accessories 3 Dispose of battery properly following any applicable local battery disposal laws 4 Dispose of device properly following any applicable lo...

Page 31: ...LS Date of manufacture Enclosure protection degree Afraid of rain Manufacturer information No throwing into the trash cans SN Serial number 8 CUSTOMER SERVICE 24 Month Limited Warranty Lifetime Technical Support ...

Page 32: ...30 Shen Zhen As Tec Technology Co Ltd 8E XinBaoYi Industrial Bld Houting Village Beiting Road Shajing Shenzhen Guangdong CN 518012 Made in China AUVON US TU2124 A sms v1 0 210825 70 120mm ...

Reviews: