background image

19 

Both  exhaust  and  intake  pipes  should  be  positioned 

inclined  downward  from  the  heater  (Fig.16).  If  this  is  not 
possible, then a hole Ø3 mm should be made at the lowest 
point to drain condensate. 

 

 

Exhaust  gas  outlet  and  combustion  air  inlet  should  be 

positioned in such a manner as

 

to eliminate the possibility of 

re-suction of exhaust gases 

 

 

The air intake inlet and the outlet of the exhaust 
pipe shall not face incoming air flow when the 
vehicle is in motion (Fig.17). 

 

 

 

When  installing  the  heater  inside  van  bodies 
(insulated vans, box vans, etc.), the exhaust pipe 
outlet and the air intake shall not be placed on 
the opposite sides of the vehicle (Fig.18). 

 
The  correct  installation  of  the  exhaust  and  air  intake 

pipes  is  on  one  side.  The  distance  between  them  should 
exclude re-suction of exhaust gases through the air intake (at 
least 200mm). 

Under  adverse  conditions  (strong  wind,  occasional 

atmospheric pressure changes), failure to comply with these 
recommendations not only prevents the discharge of exhaust 
gases,  but  also  creates  an  additional  depression  near  the  air 
intake. 

As a result, normal operation of the burner is impeded, 

it gets clogged with soot, and the life of the heater shortens. 

In  rare  cases,  failure  to  comply  with  this 

recommendation may lead to penetration of flame into the air 
blower. 

 

Summary of Contents for PLANAR-2D-12/24

Page 1: ...www autoterm ru Air heater Installation Instructions PLANAR 2D 12 24 PLANAR 4DM2 12 24 P PLANAR 44D 12 24 GP P PLANAR 8DM 12 24 P...

Page 2: ...6 Introduction 7 Application modification 7 Safety 8 Installation 9 PLANAR 2D Heater Dimensions 10 PLANAR 4DM2 Heater Dimensions 11 PLANAR 44D Heater Dimensions 12 PLANAR 8DM Heater Dimensions 13 Hea...

Page 3: ...3 Connections Diagram Main Parts and units of PLANAR 2D...

Page 4: ...4 Connections Diagram Main parts and units of PLANAR 4DM2 mod P...

Page 5: ...5 Connections Diagram Main parts and units of PLANAR 44D mod P...

Page 6: ...6 Connections Diagram Main parts and units of PLANAR 8DM mod P...

Page 7: ...tion instructions contain the necessary information and advice on the installation of air heaters PLANAR 1 Application modification Application of air heaters Air heaters are designed to heat the driv...

Page 8: ...shall not be connected to the electric circuit of the vehicle with its engine running and no battery installed Installation of the heater and its component parts shall be carried out by specialized o...

Page 9: ...length of the output duct should not exceed 5 meters in total When mounting the heater care should be taken to ensure that its housing does not have harmful contact with projecting parts of the floor...

Page 10: ...10 PLANAR 2D Heater Dimensions...

Page 11: ...11 PLANAR 4DM2 Heater Dimensions...

Page 12: ...12 PLANAR 44D Heater Dimensions...

Page 13: ...13 PLANAR 8DM Heater Dimensions...

Page 14: ...14 Heater Mounting Position...

Page 15: ...15 Heater Mounting Position...

Page 16: ...16 Heater Mounting holes...

Page 17: ...Fig 13 Installation of air ducts to the air heater PLANAR 8DM is forbidden When using a mounting box outlet should be sealed in such a manner that the box itself did not get hot air 3 5 Combustion Ai...

Page 18: ...operation of vehicle units The outlet of the exhaust pipe should be in such a position that would prevent clogging or entering of snow and also provide for free drain of any water that got into it Fo...

Page 19: ...aust pipe outlet and the air intake shall not be placed on the opposite sides of the vehicle Fig 18 The correct installation of the exhaust and air intake pipes is on one side The distance between the...

Page 20: ...20...

Page 21: ...fuel tank is shown in Fig 19 The fuel tank needs to be mounted so that fuel which can be spilled when filling a fuel tank shouldn t be applied on an exhaust system and an electrical wiring Fuel fille...

Page 22: ...mp is used for metered supply of fuel into the combustion chamber The fuel pump is operated by electrical impulses sent by the control unit The pulse frequency corresponds to the certain performance o...

Page 23: ...r connection of two fuel tubes with a coupling is shown in Fig 25 Cutting of couplings and fuel tubes should be done only with a sharp knife Interfaces shall not be crushed and must be free of burrs o...

Page 24: ...ing operation of the vehicle must be eliminated Harnesses are fastened to elements of the vehicle with plastic clips Attention Mounting shall be carried out with the fuse removed If the length of the...

Page 25: ...fastened to the panel with screws The wire is led out of the Controller housing through the back cover The Controller snaps to the bracket with an audible click 3 9 8 Cab Sensor Installation Cabin se...

Page 26: ...fuel supply line can be filled in two ways 1 to start a heater several times Time of one full start 5 minutes 2 to use the fuel pumping device Control of filling of the fuel supply line is exercised v...

Page 27: ...27 PLANAR 2D Electrical Wiring Diagram...

Page 28: ...28 Electrical Wiring Diagram PLANAR 44D PLANAR 4DM2 mod...

Page 29: ...29 Electrical Wiring Diagram PLANAR 8DM mod...

Reviews: