VIII. Chirps
Chirps
Description
1
•
LOCK
and
ARM
the system.
•
LOCK
confirmation.
•
Entering Mode 1 in Programming Options.
•
Start attempt when the Engine is already running under remote control.
•
Disarmed Notification
2
•
UNLOCK
and disarm.
•
Transmitter learnt.
•
Entering Electronic Valet.
•
Entering Mode 2 in Programming Options.
3
•
LOCK
and arm while a zone is left unprotected.
•
Entering Mode 3 in Programming Options.
•
Door zone left unprotected.
4
•
UNLOCK
and disarm: an intrusion was detected.
•
Entering the Tach Learning procedure.
5
Siren or Horn Chirp Timing adjustment.
Constant up to 30 seconds
In Horn Mode: alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up. The Horn will sound for
30 sec. (honk – pause – horn – pause ...)
Constant up to 60 seconds
In Siren Mode: alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up. The Siren will sound for
60 sec.
IX. Diagnostics - Parking Lights Flash Rate
Flashes
Description
1
•
Doors locked, Alarm and Starter Kill armed.
•
End of Run Time.
•
Run Time cancelled.
•
TRUNK
button pressed
•
START
signal received by the Module.
•
Cold Weather Mode cancelled.
•
Cannot start after maximum number of attempts is reached.
2
•
Doors unlocked, Alarm and Starter Kill disarmed.
3
•
Entering Cold Weather Mode.
•
Remote start attempt cancelled by remote.
4
•
+12 V where detected on the brake line and cranking was cancelled.
•
Entering the Tach Learning procedure.
5
•
New Transmitter learnt.
•
Tach learnt.
6
•
A remote start was attempted while a Tach or a vacuum signal was detected before cranking.
8
•
Unit reset: occurs when the Unit is reset to the factory defaults.
10
•
The Hood Switch line went to ground during cranking or Run Time.
1 – pause – 2
There was an attempt to start the vehicle while the Module was in Valet Mode.
2 – pause – 2
There was an attempt to start the vehicle while the Module was in Home Valet Mode.
ON solid
Cold Weather Mode
: the Brake Pedal is being held down.
ON 2 sec.
The Hood is up and the Hood Switch line went to ground. This is step one of the Programming
Modes.
ON 3 sec.
First press of the
START
button under Safe Start.
ON 4 sec.
•
The hood was opened and the hood switch line went to ground. This is step one of the programming centre.
•
Lock or Unlock pulse (if door pulse is configured to 4 sec.)
ON 25 sec.
•
If the Hood Pin-switch has been pressed twice (
down-up / down, up
): the Unit went into step 1 of the Programming cycle and no
Transmitter activity was detected for 20 seconds
•
Or
the Unit went into step 1 of the Transmitter Code Learning procedure and no activity was detected for a few seconds. The Unit
has exited the Transmitter Code Learning procedure.
Irregular
•
If the unit gives irregular signals (1 to 10 flashes followed by a pause, followed by further flashes), the system is playing back Start
Failure Codes. This occurs when the Hood Pin-switch is pressed three times (
down, up / down, up / down, up
)
Constant flashes
up to 30 sec.
In Horn Mode: Alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up.
Constant flashes
up to 60 sec.
In Siren Mode: Alarm condition generated by an intrusion, by Panic Mode or when the Module is powered up.
AS-6105 SH/SR
Quick Programming Guide