background image

CLOCKPLUS

T

ally/ClockPlus

On-Camera Prompter

Accessories

TallyPlus
ClockPlus

On-Camera Prompter
Accessories

Part Nos. TALLYPLUS

www.autoscript.tv

EN

Summary of Contents for ClockPlus

Page 1: ...CLOCKPLUS Tally ClockPlus On Camera Prompter Accessories TallyPlus ClockPlus On Camera Prompter Accessories Part Nos TALLYPLUS www autoscript tv EN...

Page 2: ...ated in new versions of the publication We are making every effort to ensure that our manuals are updated on a regular basis to reflect changes to product specifications and features Should this manua...

Page 3: ...17 Configuration 18 Adjusting the Opto Sensor Sensitivity TallyPlus and ClockPlus 18 Adjusting the Display Brightness TallyPlus and ClockPlus 18 Changing the Camera Number TallyPlus 19 Changing the Cl...

Page 4: ...d Safety Electrical Connection WARNING Where there is a risk of personal injury or injury to others comments appear supported by the warning triangle symbol Where there is a risk of damage to the prod...

Page 5: ...otect the product from water moisture and dust The presence of electricity near water can be dangerous WARNING When using this product outside protect from rain using a suitable waterproof cover WARNI...

Page 6: ...late with fixing thumbscrews 3 LED display digit 4 Built in opto sensor 5 Fixing screw holes 4 5 1 Front View Rear View 3 2 1 Connection and control panels left and right sides 2 Spacer plate 3 Fixing...

Page 7: ...TallyPlus No Part Description 1 SNSR Tally light opto sensor 2 MJ CPY Two accessory Y power cable 3 MTTP OL Mounting bracket for attaching the TallyPlus to moulded hoods MH S or MH W 1 2 x4 3 No Part...

Page 8: ...Connections Box Contents ClockPlus Tools Required Pozi screwdriver No Part Description 1 CLOCKPLUS Six digit ClockPlus unit 2 Spacer mounting plate 3 Power cable 0 5 m long 4 MJ C Tally repeat cable...

Page 9: ...htness adjust switch 4 Tally indicator number adjust switch 5 Tally light repeat OUT socket 6 Opto sensor IN socket 7 Opto sensor trim adjuster 1 2 3 4 5 6 7 1 DC power IN socket 6 Opto sensor trim ad...

Page 10: ...peration of the camera tally 1 Pull the mating Velcro ring from the base of the tally opto sensor 2 Peel the adhesive backing from the Velcro ring and fit it firmly around the tally indicator light on...

Page 11: ...ED TFT and LED 8 The TallyPlus is mounted to the front of the monitor over the existing tally light The built in opto sensor on the rear of the TallyPlus can then capture and replicate the status of t...

Page 12: ...screws on the wing plate with the holes on the front of the monitor 2 Tighten the two fixing thumb screws to secure the TallyPlus in position Hood Mounting 1 If fitted remove the wing plate from the T...

Page 13: ...front of the prompter monitor 1 With the spacer plate in between align the fixing thumbscrews on the ClockPlus with the holes either side of the tally light on the monitor Ensure that the centre hole...

Page 14: ...xternal tally opto sensor An external tally opto sensor directly An accessory looped through or sourced from the TallyPlus to the ClockPlus for example The accessory internal opto sensor Alternative c...

Page 15: ...or LED 8 Directly Connecting the Opto Sensor The tally opto sensor can be connected directly to the TallyPlus or the ClockPlus This is particularly useful if only one accessory is being used in the pr...

Page 16: ...The tally signal function is not available on the ELP15 TallyPlus Loop Through Connection Using the Internal Opto Sensor If the TallyPlus or ClockPlus are mounted over the tally light on the front of...

Page 17: ...socket An operator in the control room for example could then change the tally status when required Logic Control Connection On the ClockPlus a connection can be made to the Tally Input socket to feed...

Page 18: ...Power Connection Dual Power Connection If the TallyPlus and ClockPlus are being used in the same installation a dual Y power cable is available to connect DC power to both accessories at the same time...

Page 19: ...C can be connected to the ClockPlus at the same time and selected during configuration The timecode cables can be connected or disconnected whilst the unit is powered CAUTION The LTC input is balanced...

Page 20: ...at which the unit switches from green to red effectively increasing the sensitivity of the opto sensor Adjusting the Display Brightness TallyPlus and ClockPlus The brightness of the LED display digit...

Page 21: ...on the TallyPlus can be changed with the NUMBER switch Any number can be displayed in the range 0 to 9 Changing the Clock Display Format ClockPlus The format of the clock display can be changed with...

Page 22: ...lockPlus The selection of the active timecode input VITC or LTC can be changed with the V L switch If only one timecode source is connected the ClockPlus will auto select the active input and disregar...

Page 23: ...can be sourced from either the camera or monitor tally light a switch or a logic control signal Timecode Operation ClockPlus The ClockPlus can display SMPTE EBU station timecode when connected to a s...

Page 24: ...eplace as necessary Check that all cables are connected properly Cleaning During normal use the only cleaning required should be a regular wipe over with a dry lint free cloth Dirt accumulated during...

Page 25: ...ecting the Opto Sensor on page 13 Use the opto sensor trim control to adjust the switching threshold See the section Adjusting the Opto Sensor Sensitivity TallyPlus and ClockPlus on page 18 Check that...

Page 26: ...0k at 10 Lux 5K at 100 lux High illumination Red tally indication Low illumination Green tally indication Connections Data DC Power Socket TallyPlus and ClockPlus Connector type 2 1 mm DC socket Tally...

Page 27: ...nually by inserting a switching cable ground loop into the opto sensor socket An operator in the control room for example could then change the tally status when required The switching cable consists...

Page 28: ...p p Connector type 3 pin male TiniQ G miniature XLR Vertical Interval Time Code Input Socket Standard PAL or NTSC Impedance 75 balanced Level 1 V p p Connector type 75 BNC socket Technical specificati...

Page 29: ...ration of Conformity This product complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This product may not cause harmful interference 2 This product must acce...

Page 30: ...aste products By ensuring this product is disposed of correctly you will help prevent potentially negative consequences for the environment and human health The recycling of materials helps conserve n...

Page 31: ......

Page 32: ...30...

Page 33: ...A V Autoscript itec Group brand Publication part No ACC 4980 1 www autoscript tv...

Reviews: