Basic Functions

1.

To start/stop the heater by using additional remote control, see 
documentation for the remote control. The functions of the remote control 
depend on its possibilities, connection schemes and module’s settings.

2.

To start the heater by using car’s remote control key press “Unlock” button 
2 times and then press “Lock” button. Time intervals between presses must 
not exceed 20 seconds. The excess of time interval restarts the counter of 
“Unlock” button presses. 

If the car is equipped with factory alarm system, 

intervals between button pressings should be at least 6 seconds long, and 
final “Lock” pressing should be performed twice

. Car confirms reception of 

commands from the key with hazard signals flashing. 

As a result of entering

a sequence

the car should flash 2 times with long flashes, then 2 times with 

short flashes.

3.

By default RCP adjusted only to switch on the heater by using remote 
control key. To switch off the heater from the key, change the setup item 
3.1. As both the commands use the same combination of “Unlock” presses, 
you should know heater status before you send a command. Therefore it is 
recommended to activate setup items 6.4 – 6.6 to see heater status by the 
means of direction indicators flashing in rearview mirrors. The possibility to 
stop the heater remotely may be useful in case of trip cancelation, including 
one programmed in the CIP.

4.

It is possible remotely disable startups of the heater, programmed in the CIP. 
Use additional remote control to send stop command when the heater is idle 
(not possible with car’s remote control key).  Starting the heater any way or 
turning the ignition to “on” position enables CIP programs again. 

5.

Additionally installed button has several functions. Current function is 
defined by the heater status, the ignition status and the engine status (see 
table. 1)

When the ignition is turned off, the button is used for immediate start or 

stop of the heater. Button pressing changes the heater status to another one: 
switches off the operated heater or switches on the idle heater.

When the ignition is turned on, button press keeps current condition of 

the heater after the engine start. So, if the heater has operated before the engine 
start, it may continue to operate after the engine start (in the boost heat mode). 
If the heater has been idle before engine start, button pressing keeps heater 
status (heater doesn’t start in boost heat mode) after engine start. These 
functions are called quick enabling and disabling of boost heat mode 
respectively. Being activated these functions act for the current ignition cycle. 
Turning the ignition off cancels function activity.

When the engine runs, the button is used to quick enable of the boost heat 

mode (if the boost heat mode was disabled). 

Warning!

The parking heater must not be operated at filling stations, near 

sources of combustible vapours or dust or in enclosed spaces 

Summary of Contents for RCP-FM

Page 1: ...Autoplugin RCP FM Version 7 5 Technical Description User Manual Rev A ...

Page 2: ...ntrol by using car s remote control key Set of inputs for outer remote control connection Set of outputs with programmable heater status signals Remote cancellation of heater startup programmed in the driver information system of the CIP Indication of heater autonomous operation with the direction indicators flashing in the rearview mirrors Extended boost heat mode control Additional protection of...

Page 3: ... including one programmed in the CIP 4 It is possible remotely disable startups of the heater programmed in the CIP Use additional remote control to send stop command when the heater is idle not possible with car s remote control key Starting the heater any way or turning the ignition to on position enables CIP programs again 5 Additionally installed button has several functions Current function i...

Page 4: ...er will not operate with the engine while don t you enable boost heat mode again Connection RCP may be connected in two ways Plug n play connection is easy type of connection which not requires special skills Permanent connection is recommended for professional installation It needs at least some experience in car electronics Read installation manual for detailed connection schemes Additional Func...

Page 5: ... case of valid code and flash twice alternately in case of invalid code If entered digit is not correct press and release brakes button until the module indicates an error Enter the code once more in that case Several codes can be entered without exit of setup mode Turn the ignition off to exit setup mode New settings are saved in the nonvolatile memory of the module and stored there regardless of...

Page 6: ...onitoring6 4 1 Minimal battery voltage that lets the module start the heater in pre heat mode 4 1 1 Not adjusted 4 1 2 11 4V 4 1 3 11 6V 4 1 4 11 8V 4 1 5 12 0V 4 1 6 12 1V 4 1 7 12 2V 4 1 8 12 3V 4 1 9 12 4V 4 2 Minimal battery voltage that lets the module keep operating the heater in pre heat mode 2 4 2 1 Not adjusted 4 2 2 10 6V 4 2 3 10 8V 4 2 4 11 0V 4 2 5 11 2V 4 2 6 11 4V 4 2 7 11 5V 4 2 8 ...

Page 7: ...gnal feed to the output Alert_2 7 4 1 Heater started 4 7 4 2 Heater stopped 4 7 4 5 Heater started to burn 4 7 4 6 Heating finished 7 4 7 Error occurred 7 4 8 Disable the output 7 5 Signal feed to the output Status_Minus 7 5 1 Heater operates potential 7 5 2 Heater operates autonomously from battery engine is off potential 7 5 3 Hazard flashers control double impulses with the frequency adjusted b...

Page 8: ...he hazard alarm button see installation manual for details 6 Additional connections required see installation manual not available by using plug n play cable 7 For the car s remote key only Signals The module has two connectors 9 pin connector X1 table 3 for input signals and power connection 10 pin connector X2 table 4 for output signals special signals and CAN bus connection The first pin on eac...

Page 9: ...rogram start of the heater programmed by CIP X1 2 Heater_off The input can be used to switch off the heater operated in pre heat mode by the impulse of negative polarity the input Heater_off in that case has to be connected to the Power The heater is stopped by the leading edge of the impulse If the heater is idle negative impulse on this input cancels startup of the heater programmed by CIP This ...

Page 10: ...default the signal Heater operates is given on the output X2 2 Status_Minus The assignment of this output is defined by the setting 7 5 By default the signal Heater operates autonomously is given on the output X2 3 Alert_1 The signal is used to send a notification to the remote control device if remote is compatible to alerts receiving The assignment of this output is defined by the setting 7 3 Wh...

Page 11: ... codes description and possible solutions Table 5 Error Code Error Description Possible Reasons of Error Appearance Solutions 2 No answer from the heater followed the start command Outer temperature is upper than 15 Celsius degrees The heater works only at temperatures outside are below 15 C It is heater manufacturer s restriction Fuel level in the tank is close to empty Fuel Low warning indicator...

Page 12: ...heater was switched off spontaneously with operating time of less than 20 minutes Make diagnostics of the heater if the error appears again 8 CAN bus error There is a problem with connection of the module to the CAN bus Check for the module s cables connection 9 Settings error Settings have been incorrectly stored in RCP memory Reset the settings 8 1 1 readjust RCP 11 Heater no connection The heat...

Reviews: