X1.5 Button
The input for outer multi-functional button connection. The current function of the
button depends on the heater status, ignition status and the engine status (see Table
4 for more details)
X1.6 Timer_in
Not used in current version
X1.7 RC_in
The input can be used to switch the heater on/off by the impulse of positive
polarity. The heater is turned on by the leading edge of an impulse and is turned off
by the trailing edge of the impulse. The specialized remotes such as Smart Start,
Easy Start and Telestart can be connected to this input. GSM-modules with a
potential signal on the control output also may be connected to the input.
X1.8 Ground
X1.9 Power +12V
X2.1 Status_Plus
The assignment of this output is defined by the setting 7.6. By default the signal
“Heater operates” is given on the output.
X2.2 Status_Minus
The assignment of this output is defined by the setting 7.5. By default the signal
“Heater operates autonomously” is given on the output.
X2.3 Alert_1
The signal is used to send a notification to the remote control device (if remote is
compatible to alerts receiving). The assignment of this output is defined by the
setting 7.3. When programmed event is occurred, the impulse of negative polarity
with 1 second duration appears on the output. By default the signal “Heater
started” is given on the output.
X2.4 Alert_2
The signal is used to send a notification to the remote control device (if remote is
compatible to alerts receiving). The assignment of this output is defined by the
setting 7.4. When programmed event is occurred, the impulse of negative polarity
with 1 second duration appears on the output. By default the signal “Heater
stopped” is given on the output.
X2.5 Engine_RS
Not used