background image

6

2.3.

Number of 

sequential “Lock” 
button presses for 
heater control (with 
perimeter lighting 
turned on)

2.3.1  

Combination is disabled 

2.3.2  *

Two presses

2.3.3  

Three presses

2.3.4  

Four presses

3. 

Battery
Monitoring

3.1.

Minimal battery 
voltage that lets the 
module start the 
heater in pre-heat 
mode 

3.1.1

* Not adjusted

3.1.2

11.7V 

3.1.3

11.8V 

3.1.4

11.9V 

3.1.5

12.0V

3.1.6

12.1V

3.1.7

12.2V

3.1.8

12.3V

3.1.9

12.4V

3.2.

Minimal battery 
voltage that lets the 
module keep 
operating the heater 
in pre-heat mode

1

3.2.1

* Not adjusted

3.2.2

11.4V

3.2.3

11.5V 

3.2.4

11.6V 

3.2.5

11.7V

3.2.6

11.8V

3.2.7

11.9V

3.2.8

12.0V

6. 

Indication 
with
direction 
indicators in 
rearview 
mirrors

6.1.

Indication of 

the heater startup 

6.1.1  *

Off

6.1.2  

Five flashes

6.2.

Indication of 

command reception 
from a remote 
control

6.2.1  *

Off

6.2.2  

Three flashes

6.3. 

Indication of 

heater operation, 
when start source is 
a car’s key

6.3.1 *

Off

6.3.2 

On

6.4. 

Indication of 

heater operation, 
when start source is 
the CIP (direct or 
timer start)

6.4.1 *

Off

6.4.2 

On

6.5. 

Indication of 

heater operation, 
when start source is 
other than specified 
in 6.3,6.4

6.5.1 *

Off

6.5.2 

On

Summary of Contents for Key-V2

Page 1: ...Autoplugin Key V2 Version 9 8 User Manual Rev D...

Page 2: ...age Content 3 Connection 3 Basic Functions 4 Additional Functions 4 Troubleshooting 7 Glossary CAN Control Area Network digital network for data transfer in vehicles CIP Combined Instrument Panel PCC...

Page 3: ...autonomous operation Package Content 1 Autoplugin Key V2 cartridge 2 User Manual brochure Connection The module needs that 2 timers and direct start stop function for the heater control are present i...

Page 4: ...and the brakes pedal are used to enter Setup mode and to change the settings It is necessary to stop the engine and the heater before Turn the ignition on by holding the engine start button for at lea...

Page 5: ...instrument panel use LED s indication of the module for settings change Settings table 1 Settings Group Settings Item Possible Values 1 Heater operation time 1 1 Limitation of total operational time o...

Page 6: ...ep operating the heater in pre heat mode 1 3 2 1 Not adjusted 3 2 2 11 4V 3 2 3 11 5V 3 2 4 11 6V 3 2 5 11 7V 3 2 6 11 8V 3 2 7 11 9V 3 2 8 12 0V 6 Indication with direction indicators in rearview mir...

Page 7: ...Celsius degrees The heater operates only at temperatures below 15 C It is heater manufacturer restriction Fuel level in the fuel tank is close to empty Fuel Low warning indicator is illuminated in the...

Page 8: ...from OBD II socket and reconnect it 9 Settings error Settings have been stored incorrectly Reset the settings with 8 1 1 code readjust the module 11 Heater no connection The heater is unplugged or out...

Reviews: