![Autopage C3-RS-625 Installation Manual Download Page 12](http://html1.mh-extra.com/html/autopage/c3-rs-625/c3-rs-625_installation-manual_3022577012.webp)
12
WHITE WIRE – (-) 200ma PROGRAMMING OUTPUT
(See Alarm Feature A - 2 Programming)
DOME LIGHT CONTROL OUTPUT (Factory Default Setting)
—
This wire becomes grounded when the dome light control circuit is active.
The current capacity of this wire is 200mA. This wire can control the
operation of the interior lights. An optional 10 Amps relay can be added
to this system for interior lights operation.
a). Upon disarming, the interior lights will remain on for 30 seconds.
b). If the vehicle is violated, the interior light will flash for the
same duration as the siren
87a
86
87
30
85
Fuse
White Wire
+12V
Domelight
Door
Switch
Courtesy
Light
FACTORY SECURITY REARM SIGNAL OUTPUT–
(See Alarm Feature A- 2 Programming)
This wire is designed to rearm a factory installed security system. This
wire will supply a pulse whenever the remote start times out or is shut
down using the transmitter and remote door locking.
PINK WIRE – (-) 200ma PROGRAMMING OUTPUT
(See Alarm Feature A - 3 Programming)
2 STEPS UNLOCK OUTPUT (Factory Default Setting)
—
The 2 step unlock feature will work for the most fully electronic door lock
circuit. The vehicle must have an electronic door lock switch (not the
lock knob or key switch), which locks and unlocks all of vehicle’s doors.
When wired for this feature, pressing the disarm (or unlock) button one
time will disarm the alarm and unlock the driver’s door only. If you press
the disarm (or unlock) button two times within 3 seconds, the alarm will
disarm and all doors will unlock.