H-59
Economical PID Control
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
Parameter Group
※
Parameter setup
Parameter group 2
→
Parameter group 1
→
SV setting
• Set parameter as the above considering parameter relation of each setting group.
• Check parameter set value after change parameter of setting group 2.
※
Indicator model (TC4 -N N)displays shaded parameter (
) of parameter group 2.
※Alarmoperationmode[
AL-1
,
AL-2
] parameter of parameter group 2 is decided whether to display according by alarm output type.
※
If alarm operation mode [
AL-1
,
AL-2
] of parameter group 2 is set to
AM)_
/
SBa
/
LBa
,
AHYS
parameter is not displayed.
※
1: It is not displayed for AC/DC power model (TC4 - 2R).
※
If no key entered for 30 sec., it returns to RUN mode automatically and the set value of
parameter is not be saved.
※
This parameter might not be displayed depending on other parameter settings.
①
Press any key once in RUN mode, it advances to set value setting group.
②
Press
key over 2sec. in RUN mode, it advances to parameter group 1.
③
Press
key over 4sec. in RUN mode, it advances to parameter group 2.
④
First parameter will be displayed on viewer when it advances to the setting group.
⑤
Press
key over 3sec. in the setting group, it returns to RUN mode.
※
Exception: Press
key once in SV setting group it returns to RUN mode.
※
Press
key again within a sec after return to RUN mode by press
key over
3sec., it advances to the first parameter of previous setting group.
SV setting
Parameter group 1
[
PAR1
]
Parameter 2group
[
PAR2
]
①
②
③
⑤
Press any key among
, , ,
2 sec.
3 sec.
3 sec.
4 sec.
IN-T
UNIT
IN-B
MAvF
L-SV
H-SV
O-FT
C-MD
OUT
SSrM
T
AL-1
AL-2
AHYS
LBaT
LBaB
DI-K
ErMV
LOC
Input type
Temperature unit
Input correction
Input digital filter
SV low-limit value
SV high-limit value
Control output operation
Control type
Control output
SSR drive output method
※
1
Control cycle
AL1 alarm operation mode
AL2 alarm operation mode
Alarm output hysteresis
LBA monitoring time
LBA detection range
Digital input key
Control output MV in case of
input break error
Parameter lock
④
AL1
AL2
AT
P
I
D
RSET
HYS
AL1 alarm temperature
AL2 alarm temperature
Auto tuning
Proportional band
Integral time
Derivative time
Manual reset
(Normal deviation correction)
ON/OFF control hysteresis
Run mode