viii. Press 'ENTER' Key

To see meter information 
continually press to scroll down 
pages.

Page 1

Page 2

Page 3

Page 4

Page 5

Page 6

2) Function operating display:

Press 'FUNCT' key. Display will 
change to below.

On the screen above, you will see 
two asterix, one flashing.
Type in the first number of the 
required function you wish to 
see by pressing the 'ENERGY' 
key continually until you have 
reached the correct number, then 
press 'ENTER' key. Repeat for the 
second asterix. 
When both numbers have been 
entered, press the "FUNCT' key. 
This will take you to the desired 
screen.
To return to the normal screen 
press 'FUNCTION' key again.
If you enter an incorrect number 
or a function which is not 
available on this model you will 
see the screen below.

METER DESCR I PT I ON

3 PHASE 4 W I RE
230 / 400V 5A 50Hz

RAT I OS

VT 230. 0: 230.0
CT 5: 5
NT 5: 5

PULSES DETA I LS

PULSE VALUE

= 1 kWh

PULSE PER I OD = 1 00ms

RESET M D

FUNC - 0 1 2

RAT I O

FUNC - 0 1 3

CONTRAST

FUNC - 0 1 6

CONNECT I ON FUNC - 050

PULSE TEST FUNC - 060

PLEASE ENTER

FUNCT I ON NUMBER

**

FUNCT I ON SELECTED

I S NOT

 

AVA I LABLE

AUTOMETERS LTD

I C9

SER I AL N o : 900000 1

ADDRESS : 00

 

  Function 

Option   

Number

  Number

  12 

Demand reset 

 

  13 

Ratio 

CT ratio 

Primary

  16 

Display contrast  + or - 

Primary

  50 

Connection test

  60 

Pulse test 

List of function code as below:

Summary of Contents for IC7-C

Page 1: ...installation and operation manual IC7 C and IC9 C horizon r a n g e The fusion of land based metering and ether based monitoring 9...

Page 2: ...ing Slide the back of the meter first through the opening on the rear side of the door and then push the bezel from the front side over the protruding clear plastic and push fully home until it locks...

Page 3: ...t programming details for your chosen CT ratios e When the process is complete press the Function key to take you back to the default screen Note When setting CT ratios and if you have only three digi...

Page 4: ...IMPORT ENERGY KWH 000000 00 KVAH 000000 00 KVARH 000000 00 EXPORT ENERGY KWH 000000 00 KVARH 000000 00 VOLTAGE L 1 000 0 L 1 L2 000 0 L2 000 0 L2 L3 000 0 L3 000 0 L3 L1 000 0 FREQUENCY 50 00Hz AMPS L...

Page 5: ...will take you to the desired screen To return to the normal screen press FUNCTION key again If you enter an incorrect number or a function which is not available on this model you will see the screen...

Page 6: ...50 To check connections enter function 50 See Page 5 function operation display Press Funct key to see connections Press Funct key to return to normal display PULSE TEST Function 60 To test the relay...

Page 7: ...ches needs to be in the on position To allocate meter register number 14 dill switches numbers 5 6 and 7 must be in the on position To allocate meter register number 39 dill switches numbers 3 6 7 and...

Page 8: ...se Duration 80 100 ms closure Pulse Value C T Value less than 1000 5A 1 kWh imp C T Value 1000 5A or more than 10 kWh imp 0 4 0 3 0 2 0 1 0 1 0 2 0 3 0 4 0 1 1 0 2 0 3 0 4 0 5 0 6 0 IC9 Load Curve 0 5...

Page 9: ...n depth stock holding combine to provide a level of service which has earned the appreciation of customers across the spectrum of the UK and export markets Computerised distribution systems are geared...

Reviews: