3. What is the short circuit current of the wind turbine?
Use a multimeter to determine if a short circuit current is as expected.
There might be a loose / faulty wire connection.
4. Is the turbine’s voltage close to the battery voltage?
If so, the panels could be warm/hot causing the Maximum Power Point
of the array to be at or lower than the battery voltage.
MPPT sweeping frequently
1. What is the current limit set point?
When the current limit set point is achieved the MPPT will continue
sweeping to maintain the targeted current limit.
2. What is the sweep interval set point?
A short sweep interval time will cause the MPPT to sweep frequently.
A sweep interval of 7 to10 minutes is recommended.
MPPT Internal Fan
Should the internal fan be running when the MPPT is producing power?
The internal fan will only run when the internal temperature has reached ~ 65
degrees Celsius or 149 degrees Fahrenheit.
Warranty
This product is covered under a one-year limited warranty. Warrants to the
original purchaser that this product is free from defects in materials and
workmanship for one year from the date of purchase. Please note that proof
of purchase including date, and the expiration of complaint is required for
warranty service.
Downloadable APP for Bluetooth Function