21
ATS Series Instruction Manual
Parameter
Value options = Indicated by brightness of main light
(DEFAULT parameter underlined)
Name
Flashes
1
2
3
4
5
6
7
8
9
10
MARGIN
1
0.7A
0.69A
1.2A
1.5A
2.0A
-
-
-
-
-
PE AUTO-CLOSE
2
OFF
15sec
30sec
60sec
90sec
-
-
-
-
-
AUTO-CLOSE
3
OFF
15sec
30sec
60sec
90sec
120sec
-
-
-
-
LIGHT TIMER
4
30sec
60sec
90sec
120sec
180sec
240sec
-
-
-
-
B - Adjustment Mode Instructions
a. Press the MODE button until the GEAR
LED starts flashing
b. Referring to the table below, select the desired parameter using the OPEN
and CLOSE
buttons and observing the
number of flashes on the GEAR
LED. The selected parameter’s value is indicated by the main light’s brightness.
c. Press STOP / SET button to start editing the parameter’s value. The TRANSMIT
LED will turn on when editing is active.
d. Use the OPEN
and CLOSE
buttons to step through the available options. The light’s brightness will change
accordingly.
e. Press STOP / SET button to save the parameter’s new value or press MODE to leave the value unchanged.
f. Continue from a. above to select another parameter or press MODE to exit adjustment mode.
D - Battery Functions
a. Holding the STOP button for 10secs when running from battery backup will shut the PCB down so as to reduce
battery current consumption to a minimum.
b. Holding the STOP button for 4secs when a battery is fitted and running from mains power will cause the controller
to test the battery state to determine if it is disconnected / open circuit, missing, faulty or ready.
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically during
setup. Adjusting this is normally only necessitated by environmental
conditions such as windy or dusty areas, and areas with extreme
temperature changes.
To Increase / Decrease Force Pressure
a. Press the MODE button until the GEAR
LED is flashing.
b. The LED will start flashing with one flash every second.
c. Press the STOP / STEP button and the MODE button LED and the
TRANSMIT
LED will be lit and the GEAR
LED will flash
once every second.
d. By pressing the OPEN button
will increase the force pressure
and CLOSE button
will decrease the force - Main light will
dim or brighten as the pressure is decreased or increased.
e. Press STOP / SET button to save the new value. (Refer to
Appendix B for margin settings)
f. Test the force again as per Testing Close Cycle and Testing Open
Cycle.
C - Adjusting Force Margins
24. Appendix
Summary of Contents for TEMPO ATS-2
Page 24: ......