![Automatic Technology SecuraLift GDO-7V1 Owner'S Installation Instructions Manual Download Page 8](http://html1.mh-extra.com/html/automatic-technology/securalift-gdo-7v1/securalift-gdo-7v1_owners-installation-instructions-manual_3021679008.webp)
8
GDO-7V1 SecuraLift®
Owner Installation Instructions
Operating controls
P. E. Shunt.
The shunt has to be removed when connecting a Photo Electric Beam.
NOTE:
P.E. Shunt must not be removed otherwise the opener will not function correctly. Remove only
when a P.E beam is to be connected. PROG INPUT is used for the connection of the ATA Handheld
Programmer for the purpose of editing control and receiver functions.
Terminal Block.
24V PWR is used to power devices such as photo electric beams.
PE (Input) for photo electric beam for safety and auto-close function.
LGT (Input) allow hard wired external trigger for the opener’s courtesy light.
O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch can then be
used to open, stop or close the door. Install the wall switch in a location where the switch is out of reach
of children and the garage door is visible.
Set
button (yellow) is used during the installation phase together with the Open and Close buttons to set
the door limit positions. The Set button is also used to re-initialize the Opener.
Operate
button (Yellow) is used during installation to test the open, stop and close cycles for the opener.
The opener has to be initialized by the Reset button before the O/S/C button becomes operable.
Plus (+)
button (green) is used during installation to help set the open limit position. Pressing and
holding this button will move the door in the open direction. Movement stops when the button is
released.
NOTE:
The open safety obstruction detection is inoperable whenever the Open or Close Drive button is
used to move door.
Open limit led
(green) the led is very helpful during installation. It illuminates and flashes when the door
is opening and remains steady on when the open limit position has been reached.
Force margin set
Button The obstruction force pressure is set automatically by the opener during
installation. The pressure can be adjusted manually using the Force Margin Set button (White). Holding
the Force Margin Set button and pressing the Plus (+) or Minus (-) button will increase or decrease the
amount of force. The Force Margin Set is only ever used if other environmental factors (wind, etc.) effect
the operations of the door/opener.
Light code
button (white) is used for storing or erasing the transmitter button (code) you wish to use to
switch the courtesy light on the opener on or off.
Coding led
(red) light flashes when a code is being stored or when a transmitter button is pressed.
Door code
button (blue) is used for storing or erasing the transmitter button you wish to use to
command the door to open, stop or close.
Door status LED
(Yellow)
Minus (-)
button (red) is used during installation to help set the close limit position. Pressing and holding
this button will move the door in the close direction. Movement stops when the button is released.
NOTE:
The close safety obstruction detection is inoperable whenever the Open or Close Drive button is
used to move door.
Close limit LED
(red) the led is very helpful during installation. It illuminates and flashes when the door is
closing and remains steady on when the close limit position has been reached.
01
02
03
04
05
06
07
08
09
10
11
12
13