P. E. Shunt. 

The shunt has to be removed when connecting a Photo Electric Beam. 

NOTE: 

P.E. Shunt must not be removed otherwise the opener will not function correctly. Remove only 

when a P.E beam is to be connected. PROG INPUT is used for the connection of the ATA Handheld 
Programmer for the purpose of editing control and receiver functions. 

Terminal Block.

 24V PWR is used to power devices such as photo electric beams. 

PE (Input) for photo electric beam for safety and auto-close function. 

LGT (Input) allow hard wired external trigger for the opener’s courtesy light. 

O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch can then be 
used to open, stop or close the door. Install the wall switch in a location where the switch is out of reach 
of children and the garage door is visible. 

Set 

button (yellow) is used during the installation phase together with the Open and Close buttons to set 

the door limit positions. The Set button is also used to re-initialize the Opener. 

Operate

 button (Yellow) is used during installation to test the open, stop and close cycles for the opener. 

The opener has to be initialized by the Reset button before the O/S/C button becomes operable. 

Plus (+)

 button (green) is used during installation to help set the open limit position. Pressing and 

holding this button will move the door in the open direction. Movement stops when the button is 
released. 

NOTE: 

The open safety obstruction detection is inoperable whenever the Open or Close Drive button is 

used to move door.

Open limit led 

(green) the led is very helpful during installation. It illuminates and flashes when the door 

is opening and remains steady on when the open limit position has been reached. 

Force margin set

 Button The obstruction force pressure is set automatically by the opener during 

installation. The pressure can be adjusted manually using the Force Margin Set button (White). Holding 
the Force Margin Set button and pressing the Plus (+) or Minus (-) button will increase or decrease the 
amount of force. The Force Margin Set is only ever used if other environmental factors (wind, etc.) effect 
the operations of the door/opener. 

Light code 

button (white) is used for storing or erasing the transmitter button (code) you wish to use to 

switch the courtesy light on the opener on or off. 

Coding led 

(red) light flashes when a code is being stored or when a transmitter button is pressed. 

Door code

 button (blue) is used for storing or erasing the transmitter button you wish to use to 

command the door to open, stop or close. 

Door status LED

 (Yellow) 

Minus (-) 

button (red) is used during installation to help set the close limit position. Pressing and holding 

this button will move the door in the close direction. Movement stops when the button is released. 

NOTE:

 The close safety obstruction detection is inoperable whenever the Open or Close Drive button is 

used to move door. 

Close limit LED

 (red) the led is very helpful during installation. It illuminates and flashes when the door is 

closing and remains steady on when the close limit position has been reached. 

01

02

03

04

05

06

07

08

09

10

11

12

13

Summary of Contents for SecuraLift GDO-7V1

Page 1: ...GDO 7V1 SecuraLift Overhead Garage Door Opener INSTALLATION INSTRUCTIONS OWNERS COPY...

Page 2: ...such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Techno...

Page 3: ...Pane 17 Setting Travel Limits Transmitter 18 Safety Obstruction Force Test 19 Coding Transmitters 20 Door 20 Courtesy Light 20 Vacation Mode 20 Pet Mode 20 Storing Transmitter From Remote Location 21...

Page 4: ...ning DO NOT allow children to operate the garage door opener serious personal injury and or property damage can result from failure to follow this warning Regularly check to make sure that the safety...

Page 5: ...electrical contractor Disconnect the power cord from mains power before making any repairs or removing covers Only experienced service personnel should remove covers from the garage door opener When u...

Page 6: ...rakes opener has anti travel electronic brake mechanism which ensure the opener stops the door at exact location ISS intelligent safety obstruction system While the door is performing a close cycle sh...

Page 7: ...n mode can be used when the door is left idle for long periods of time Pet pedestrian mode The hand held transmitter can be programmed to open the door partially so that the family pet can enter and e...

Page 8: ...open safety obstruction detection is inoperable whenever the Open or Close Drive button is used to move door Open limit led green the led is very helpful during installation It illuminates and ashes...

Page 9: ...ssing the open button the time is increased Each press will increase the time by 5 seconds Pressing the close button will decrease the time Engage disengagement cord when pulled down and released this...

Page 10: ...ing transmitter pack 1 Pack includes two keyring transmitters two batteries and one wall mount bracket for ptx4 transmitter Easy access transmitter EAT 1 not available some models 1 Tubes 5 Tube inser...

Page 11: ...ed to wrap chain around drive unit sprocket and chain spreader then follow along the pipe to the idler wheel on support pipe assembly nally attach to the other end of the chain index screw NOTE Make c...

Page 12: ...n tracks Fig 3 proceed with the installation from Step 5 For a one piece door on tracks Fig 4 proceed with the installation from Step 5 For a one piece door without tracks on springs Fig 5 proceed wit...

Page 13: ...er position attach the support pipe assembly to wall bracket with 90 mm long clevis pin and secure with supplied spring clip Fig 8 leaving drive unit in its packing box for protection during installat...

Page 14: ...he M6 X 16 Flanged Head Bolts 2 and M6 Flanged Head Nuts 2 and secure the hanger straps to the anti vibration brackets as per the diagrams The brackets may have to be pushed lightly on an angle to all...

Page 15: ...s it moves Stop the door when it is at its highest point of travel Fig 12 Allow 25mm additional height for clearance between the door and the track Support pipe tube in this position and the close the...

Page 16: ...use the bend straight arm If installing on a door with bad wave action lengthening the arm even further will assist the door operation by reducing the wave action The easy access transmitter The Easy...

Page 17: ...ess the set button This action will store intomemory the closed limit position 3 Press the green Plus button the door will startopening Release the button once you have reached your desired open limit...

Page 18: ...performed The door will also automatically re open after fully closing with a small pause between the cycles 6 Once you are happy with the position press button 2 this action will store into memory th...

Page 19: ...y not necessary to adjust the Safety Obstruction Force The only time the force may need to be increased is due to environmental conditions for example windy or dusty areas and areas with extreme tempe...

Page 20: ...same button for two seconds Please note that when vacation mode is activated all stored transmitters will be locked out This mode can only be deactivated by a transmitter which has been stored to acti...

Page 21: ...s Press the same button again on the transmitter for two seconds the button should now be recorded 5 Wait for 10 seconds and then press the recorded transmitter button to see if it operates the door 2...

Page 22: ...ode The Auto Close timer will only start after the Photo Electric Beams P E path is broken and the auto close time has been set If the P E path is not broken the door will remain open till the path is...

Page 23: ...you should hear three beeps and the Open and Close LEDs will ash rapidly 2 Press the Plus or Minus button Fig 32 to move the door to your required new pet open door position 3 Press the Set button Fig...

Page 24: ...llow Beeper Open On Close On Opening Flashing Closing Flashing Door travel stopped Flashing Door obstructed when opening Flashing Door obstructed when closing Flashing Beeps while door is moving Opene...

Page 25: ...e auto close delay time Auto Close Time then Set Reloads the factory set default auto close delay time Force Margin Set Auto Close Time then Plus Each press of the open button increases the light time...

Page 26: ...n Instructions Factory Default Settings Default Step Maximum Maximum motor run time 30 secs Courtesy light time 4 mins 10 secs 10 mins Obstruction force margin 3 1 27 Auto close time 0 secs 5 secs 4 m...

Page 27: ...me 30 secs Transmitter Code Storage Capacity 24 x 4 button transmitters Code type Hopping code No of code combinations Over 4 29 billion random codes PTX 4 transmitter battery A23 Alkaline 12 Volts EA...

Page 28: ...r will not close fully Door limits positions need to be reset Reset limits positions Step 15 page 17 Door will not open fully Door limits positions need to be reset Reset limits positions Step 15 page...

Page 29: ...Installation Instructions GDO 7V1 SecuraLift 29 Maintenance record Record any maintenance in the following table to assist in any warranty service Date Maintenance performed by Signature Amount Invoi...

Page 30: ...Chain idle wheel 02962 33 Snap pin ssp 8 znu 31080 10720 34 Snap pin ssp 12 znu 31120 10730 35 Cable clamp acc 15 3 16 11750 36 Globe 250v 60w 14120 37 Pan head screw w washer m5x10 10281 Item descri...

Page 31: ...Owner Installation Instructions GDO 7V1 SecuraLift 31...

Page 32: ...components b any cost relating to damage resulting from wear and tear c blown fuses loss or damage caused by electrical surges power surges or power spikes d loss or damage due to theft re ood rain wa...

Page 33: ...ng globes batteries and fuses 12 This warranty is not transferable 13 Where the Product is retailed by any person other than ATA except for the warranty set out above such person has no authority from...

Page 34: ...ATE OPENERS REMOTE CONTROL ACCESS SOLUTIONS Automatic Technology Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 P 1300 133 944 E sales ata aust com au www ata aust com au...

Reviews: