27
System specifications
Technical Specifications
Maximum residential overhead garage door area
16.5m
2
Door Load
Door Load Rated Load: 150N (15kg)
Push pull force 600N (60kg)
Short term peak load 700N (70kg)
Supply voltage:
230 - 240 V AC 50Hz
Motor type
1/3 H.P. (AC) Alternating Current
Current
Max 5A
Globe
Edison (screw mount) 240V 60W Rough Service (or
construction type)
Limit adjustment
Electronic - semi-automatic
Force control
fully automatic. Can be adjusted for environmental
reasons
Transmitter frequency
433.92MHz
Powerhead weight
7.75kg
Max. Opener Run Time
30 secs
Transmitter Code Storage Capacity
24 x 4 button transmitters
Code type
Hopping code
No. of code combinations:
Over 4.29 billion random codes
PTX-4 transmitter battery:
A23 Alkaline 12 Volts
EAT-1 Transmitter Battery
CR1220 Lithium 3 Volts
NOTE:
1. The maximum door opening on which the SecuraLift
®
can be installed is 6000mm wide by 2400mm high or with
an optional extension kit - 5500mm wide by 2700mm high. Door surface area must not exceed 15m2. The door
must be well balanced. A person should be able to lift the door up manually with very little effort in case of an
emergency.
2. Intermittent operations may occur in areas which experience very strong winds. Strong wind puts extra pressure
on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.