Diamond PD
Power Drive
: Instruction Manual
Dominator Tempo & Syncro Instruction Manual
ATS-3AM & ATS-2AM
25
© Copyright 2019
Parameter
Value options = Indicated by brightness of main light
(DEFAULT parameter underlined)
Name
Flashes
1
2
3
4
5
6
7
8
9
10
MARGIN
1
0.7A
0.9A
1.2A
1.5A
2.0A
-
-
-
-
-
PE AUTO-CLOSE
2
OFF
15sec
30sec
60sec
90sec
-
-
-
-
-
AUTO-CLOSE
3
OFF
15sec
30sec
60sec
90sec
120sec
-
-
-
-
LIGHT TIMER
4
30sec
60sec
90sec
120sec
180sec
240sec
-
-
-
-
B - Adjustment Mode Instructions
a. Press the MODE button repetively until the GEAR
LED starts flashing
b. Referring to the table below, select the desired parameter using the OPEN
and CLOSE
buttons and observing the number of flashes on
the GEAR
LED. The selected parameter’s value is indicated by the main light’s brightness.
c. Press STOP / SET button to start editing the parameter’s value. The TRANSMIT
LED will turn on when editing is active.
d. Use the OPEN
and CLOSE
buttons to step through the available options. The light’s brightness will change accordingly.
e. Press STOP / SET button to save the parameter’s new value or press MODE to leave the value unchanged.
f. Continue from a. above to select another parameter or press MODE to exit adjustment mode.
D - Battery Functions
a. Holding the STOP button for 10secs when running from battery backup will shut the PCB down so as to reduce battery current
consumption to a minimum.
b. Holding the STOP button for 4secs when a battery is fitted and running from mains power will cause the controller to test the battery
state to determine if it is disconnected / open circuit, missing, faulty or ready.
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically during setup. Adjusting
this is normally only necessitated by environmental conditions such as windy or
dusty areas, and areas with extreme temperature changes.
To Increase / Decrease Force Pressure
a. Press the MODE button repetitively until the GEAR
LED is flashing.
b. The LED will start flashing with one flash every second.
c. Press the STOP / STEP button and the MODE button LED and the
TRANSMIT
LED will be lit and the GEAR
LED will flash once every
second.
d. By pressing the OPEN button
will increase the force pressure and
CLOSE button
will decrease the force - Main light will dim or brighten
as the pressure is decreased or increased.
e. Press STOP / SET button to save the new value. (Refer to
Appendix B for margin settings)
f. Test the force again as per Testing Close Cycle and Testing Open Cycle.
C - Adjusting Force Margins