6.9 Accessories
6.9.1 Terminal Block
A variety of wired accessory items can be connected to the terminal block
J7
such as Safety Beam, Electric Key Switch and more
(Fig. 6.9.1)
.
Terminal connections from top down are as follows:
1.
V+
(+35V/+24V);
2.
EB1
(Safety Beam input, mandatory);
3.
0V
(0V for Safety Beam);
4.
EB2
(Safety Beam input);
5.
0V
(Common ground for accessories and Safety Beam);
6.
OSC
(Open/Stop/Close trigger)
7.
AUX OUT
(Auxiliary output trigger)
Fig.6.9.1
V+
EB1
OV
EB2
0V
OSC
AUX
IMPORTANT WARNING
LOCATE THE WALL MOUNTED REMOTE CONTROL:
(1) WITHIN SIGHT OF DOOR.
(2) AT MINIMUM HEIGHT OF 5 FEET ABOVE FLOORS,
LANDINGS, STEPS OR OTHER ADJACENT WALKING
SURFACE SO SHALL CHILDREN ARE NOT ABLE TO
REACH IT, AND
(3) AWAY FROM MOVING PARTS OF THE DOOR.
(4) PLACE THE ATTACHED ENTRAPMENT WARNING LABEL
ON WALL NEXT TO WALL MOUNTED TRANSMITTER.
USE AN ADDITIONAL MECHANICAL MEANS (PLATE,
BOARD, ETC.), WHICH CAN SECURE THE LABELS
TO SURFACES TO WHICH THE ADHESIVE WILL NOT
ADHERE.
(5) DO NOT REMOVE OR PAINT OVER THIS LABEL.
6.9.2 Installation of Wall Mounted Transmitter
Refer to the below warning before installing the wall transmitter
(Fig 6.9.2)
.
To set the transmitter codes refer to
Section 6.10.1
.
IMPORTANT
PLACEZ LA TÉLÉCOMMANDE MURALE :
(1) EN VUE DE LA PORTE.
(2) À UNE HAUTEUR D'AU MOINS 1,50 M (5 PIEDS) AU-
DESSUS DU SOL, DU PERRON, DES MARCHES, ETC.
AFIN QUE LES PETITS ENFANTS NE PUISSENT PAS
L'ATTEINDRE,
(3) ET À DISTANCE DES ÉLÉMENTS MOBILES DE LA PORTE.
(4) PLACEZ L'ÉTIQUETTE AVERTISSANT DU RISQUE
DE SE FAIRE PIÉGER SUR LE MUR À PROXIMITÉ DE
L'ÉMETTEUR. UTILISEZ UN SUPPORT PHYSIQUE
SUPPLÉMENTAIRE (PLAQUE, PANNEAU, ETC.)
PERMETTANT DE FIXER LES ÉTIQUETTES SI ELLES
N'ADHÈRENT PAS À LA SURFACE DU MUR.
(5) CETTE ÉTIQUETTE NE DOIT PAS ÊTRE RETIRÉE NI
PEINTE.
Fig.6.9.2