Diamond PD
Power Drive
: Instruction Manual
Dominator EasyRoller Instruction Manual
15
© Copyright 2018
6.7. Setting the Travel Limits
6.7.1 Initial Preparation:
a.
Move the door to the half way position.
b. Engage the opener by pulling down on the manual release string until
a click sounds
(Fig.6.7.1)
.
c.
Remove the clear button cover from the unit.
d. Switch power on to the opener. The red CLOSE LIMIT LED will be
flashing.
e.
Press and hold the CLOSE button - the door should start closing.
NOTE:
If the door opens, release the CLOSE button and press the OPERATE
button once to change the motor’s direction.
Pull string
down to
engage
opener
6.7.2 Set the Limit Positions:
The Limit Positions can vary due to site conditions, such as uneven ground.
When setting the Close limits, ensure the position is when the door makes
first contact with the ground. Alternatively for the Open limits the position
should be at the height of the garage opening.
a.
Press and hold CLOSE button until the door reaches your desired
close limit position. The rubber strip at the bottom of the door should
form a good seal with the ground.
b. Release the CLOSE button when the door is near the desired closed
position. Single presses of the CLOSE button will inch the door closer
to the ground.
c.
If the door overshoots press the OPEN button to move the door in the
open direction.
d. When the door is at the desired close position, press the SET button,
the OPEN LIMIT LED will now flash.
e.
Press and hold the OPEN button until the door reaches your desired
open limit position. Single presses of the OPEN button will inch the
door open.
f.
If the door overshoots press the CLOSE button to move the door in
the close direction.
g. When the door is at the desired open position, press the SET button.
WARNING! In setting the close limit position, do not
force the door into the floor with excessive force, as
this can interfere with the ease of operation of the
manual release mechanism.
h.
The door will now automatically close and open to calculate the safety
obstruction settings.
6.7.3 Resetting the Door Limit Positions
Limit positions can be deleted by:
a.
Press and hold CLOSE button for six (6) seconds until the CLOSE
LIMIT LED flashes quickly.
b. Release the CLOSE button.
NOTE: If no action is taken within 30 seconds, the opener will return to
normal operating mode and restore the original settings.
c.
Follow steps a - f in Set the Limits Poisitions to set new limit positions.
WARNING! The door will automatically close, open and
close again after the next step. Ensure that nothing is in
the door’s path.
6.7.4 Setting the PET Mode position
When activated, PET mode drives the door to a preset position from the
close position, therefore allowing a pet or parcel to go under the door.
a.
Drive and stop the door at the deisred PET mode open position
by pressing the transmitter button coded for Open/Stop/Close
operation.
b. Press and hold the OPEN button on the opener for six (6) seconds
until the OPEN and CLOSE LED’s are lit to record the new PET
position.
c.
Release the OPEN button.
6.7.5 Reset all Factory Defaults
a.
Turn power to the opener off.
b. Press and hold the SET Button.
c.
Turn power on while holding the SETbutton. Continue to hold
until all LED’s are off.
d. This will NOT erase transmitter codes stored in memory.
Fig.6.7.1
Fig.6.7.2
AVERTISSEMENT! La porte va se fermer puis s’ouvrir
automatiquement, avant de se fermer. S’assurer que rien
ne bloque l’ouverture ou la fermeture de la porte.