Owner Installation Instructions
GDO-10V3L2 Toro
™
23
Parameter
Min
Max
Default
Step
Unit
Menu No.
Section
Menu 6 - Operating Modes
Safety Close Mode
Off
On
On
6.1
16.1
Safety Open Mode
Off
On
Off
6.2
Appendix C
Safety Beam Input Response Mode Sets the S.B response
mode. Options are OPEN and CLOSE cycles stop, Close
cycles stop or Close cycle reverse
OPN & CLS stop
CLS to stop
CLS to reverse
CLS to
reverse
6.3-5
Appendix C
SB REVERSE TIME
5
FULL
FULL
1
Sec
6.6
Appendix C
GPI INPUT MODE configure the GPI input. Options are
OSC, PED, SWP and DAY LIGHT SAVING
OSC,
PED, DST
OSC
6.7
Appendix C
PED INPUT = SWIPE MODE Selects PED input functions
as pedestrian access swipe input
Off
On
Off
6.8
Appendix C
OPN INPUT N/C OPERATION
Selects operating polarity of OPN input
Off
On
N/O
6.9
Appendix C
STP INPUT N/C OPERATION
Selects operating polarity of STP input
Off
On
N/O
6.10
Appendix C
FIRE INPUT N/C OPERATION
Selects operating polarity of FIRE input
Off
On
N/O
6.11
Appendix C
FIRE INPUT MODE configure the fire input. Options are
OPN, CLS and PED
OPN,
CLS, PED
OPN
6.12
Appendix C
REMOTE CODE ENABLED
Selects remote transmitter coding function
Off
On
On
6.13
Appendix C
ACTIVITY REPORTS Select report to be output
Off
255
Off
1
6.14
Appendix C
ACTIVITY REPORT ID
Selects ID for controller, sent with activity report
0
65535
0
1
6.15
Appendix C
VACATION MODE
Selects Vacation Mode - disables remote control
Off
On
Off
6.16
Appendix C
BATTERY/SOLAR MODE
Selects Battery Backup/Solar operation
Off
On
On
6.17
Appendix C
PASSWORD
Selects password protection for all changes
Off
On
Off
6.18
Appendix C
Transmitter Grouping
Off
On
Off
6.19
Appendix C
Fault Auto Reset
Selects Fault Auto Reset
Off
On
Off
6.20
Appendix C
LED Low Power Mode
Selects saving the power by turning LEDs Off
Off
On
Off
6.21
Appendix C
Console OSC Buttons
Selects to lock out the console buttons
Off
On
On
6.22
Appendix C
AUX OUT O/P can be activated by either LIGHT DRIVE
,CLOCK/TXER / SB, OPEN or CLOSE status
LIGHT
DRIVE
6.23
Appendix C
SBFEC MODE In the event of Safety Beam failure the door
can be closed by pressing and holding a button on remote
or on console
Off
On
On
6.24
Appendix C
Menu 7 - Time Clock
SET TIME / DATE
Off
On
Off
7.1
17.1
VIEW / EDIT PROGRAMS
Off
On
Off
7.2
17.2
SETTINGS
Off
On
Off
7.3
17.3
Menu 8 - Diagnostics
TEST INPUTS - Controls input display status
Inactive
8.1
Appendix D
TEST TRANSMITTERS (TX’ERS)
8.2
Appendix D
DISPLAY HISTORY
8.3
Appendix D
MEMORY USAGE
8.4
Appendix D
SERVICE COUNTER
60,000
8.5
Appendix D