10
GDO-10V3L2 Toro
™
Owner Installation Instructions
8. Setting Limits
To Desired
CLOSE Limit,
SET
To Desired
OPEN Limit,
SET
8.1 Setting Travel Limits
WARNING! Use caution when operating the manual
release with the door open since it may fall rapidly due
to weak or broken springs, or an improperly balanced
door.
WARNING! Do not disengage the opener to manual
operation with children, persons or any objects including
motor vehicles within the doorway.
WARNING! In setting the close limit position, do not
force the door into the floor with excessive force, as
this can interfere with the ease of operation of the
manual release mechanism.
a. Secure the engage/disengage handle and string with the
accessory supplied in such a manner so that the string is away
from the moving parts.
b. Move the door to half way open. If necessary, disengage the
opener by pulling the cord down
(Fig.8.1)
.
Re-engage the opener
by pulling the cord
down again.
c. Unscrew the screws at the bottom of the logic console cover
(Fig.8.2)
and remove the cover to access the PREV, NEXT and
SET buttons.
d. Turn on the power to the opener. The controller will go through
a start up sequence.
After a short delay the MAIN SCREEN
(Fig. 8.3)
will be displayed. If this is the first time the
GDO-10V3L2 is being used, the MAIN SCREEN should enter
into limit set mode and the blue close LED will be flashing. If the
display shows that an input is active, then rectify the situation
before continuing with the procedure for setting the travel limits.
Press and hold the CLOSE button - the door should start closing.
i. If the door opens, release the CLOSE button and press the STOP
button once to change the motor’s direction. Press and hold the
CLOSE button until close position of the door is reached.
ii. If the door overshoots press the OPEN button to move the door in the
open direction.
e. When the door is at the desired close position, press the SET
button to record the close limit position. The display will change
and green open LED will start to flash
(Fig. 8.4)
.
f. Press and hold the OPEN button to open the door. When the door
is at the desired open position, release the OPEN button. If the
door overshoots, press the CLOSE button to move the door in the
CLOSE direction.
WARNING! Once the next step is performed, the door
will automatically close and open to calculate force
settings. Keep persons and objects clear of the door.
g. Press the SET button to store the open limit. The door will now
automatically close and open to calculate the safety obstruction
settings. After this, if Safety Beam is installed, the opener can be
operated with the OPEN or CLOSE button on the wall control unit
or from the transmitter. Otherwise, the controller will be loaded with
“Safety Close Mode.” See Section 13.1 for further details.
h. Place cover back on logic console and affix with screws when unit
setup is complete.
Pull Down To
Engage/Disengage
Fig 8.1
Fig 8.3
Fig 8.4
WARNING!
Please test the manual
release mechanism to ensure that the
manual release is easy to operate. No
more than 15 kg of force should be
required to disengage the door using the
manual release cord. If excessive force is
required reset the close limit position.
Fig 8.2
Fig 8.5
Fig 8.6