FUNCTIONS
LMG21.../LMG25...
LMG22...
Internal diagram LMG21/25
Operations key
AL
Alarm
BV
Fuel valve
EK2
Remote reset button
FS
Flame presence signal
GP
Gas detection pressure switch
LP
Air pressure switch
LR
Burner's output regulation
M
Fan motor
R
Safety thermostat or pressure switch
SB
Safety limit
W
Regulation thermostat or pressure
switch
Z
Ignition transformer
tw
Waiting time
t1
Pre-ventilation time
TSA Ignition safety time
t3
Pre-ignition time
t3n
Ignition time during “TSA”
t4
Interval BV-BV2 or BV1-LR
t10
Specified time for air pressure signal
t11
Programmed opening time for actua-
tor SA
t12
Programmed closing time for actuator
SA
Internal diagram LMG22