RAM™ 280-F Frozen Fry Dispenser
Copyright © 2011 Automated Equipment LLC All rights reserved.
23
Error Detection
The main display and Basket Size Button LED lights will flash with the detection of an error condition for
the effected side. The display will state the error that has occurred. (i.e. “
Err 4
”)
If an error does occur, it is normally reset by pushing the Enter
Button. If the failure continues, turn
the Power Switch off and unplug the Power Cord from the wall outlet. Check the Power Cord for any
obvious defect. Open the Cabinet Door to make sure the dispenser is properly assembled (
pages 6-11
)
and the product is loaded properly.
See
pages 24-26
for troubleshooting an error condition.
Error Codes
Error
Description
01
Timeout error on left accumulator.
02
Timeout error on right accumulator.
03
Left Tare weight has shifted excessively.
04
Right Tare weight has shifted excessively.
05
Refrigeration progress too slow. (>25°F for 1.75 Hr)
06
Refrigeration High Pressure Switch has tripped.
07
Error on refrigeration relay drive.
08
Temperature Probe input out of range.
09
Invalid data in Configuration (normal first time)
10
Internal System Error
Note: Errors 5, 6 & 7 are refrigeration errors.
These errors, while requiring corrective action, will not
disable the fry dispensing portions of the equipment. In order to safeguard the refrigeration system
these are hard errors and may not reset by pushing the Enter
Button. These errors are reset from
the Diagnostic Menu using Diagnostic Function
D08
.
Call our Technical Support Hot Line for assistance with these errors.