RAM™ 280-F Frozen Fry Dispenser
Copyright © 2011 Automated Equipment LLC All rights reserved.
22
D13
Bypass Refrigeration
Note:
Volatile Setting
Allows the refrigeration system to be disabled.
Display will read the current status of the refrigeration system
(
rF on
or
rF OFF
).
Up arrow enables the refrigeration system.
Down arrow disables the refrigeration system.
Enter button saves the setting, exits the function and
return to D1.
Note:
The refrigeration circuit contains anti-short-cycle
protection. The refrigeration compressor cannot be restarted
until the 2 minute short cycle delay is met.
D14
Display Scale Weight
Displays the current calibrated weight on the scale.
Display will read “
[SCL]
” with alternating flashing brackets.
Use Size Buttons to select the side to be displayed.
Enter Button exits function and returns to D01
D15
Display Scale Volts
Displays the current uncalibrated input from the scale.
Display will read “
[SCL]
” with alternating flashing brackets.
Use Size Buttons to select the side to be displayed.
Enter Button exits function and returns to D01
D16
Exercise Mode
Note
: Volatile Setting
Caution:
Ensure the
hopper is empty before
using Exercise Mode
Exercise mode is designed to “break in” a replaced
component. When the dispenser is in exercise mode, the
selected side(s) will continuously cycle.
Display will read “
[-E-]
” with alternating flashing brackets.
Use Size Buttons to select the side to be exercised.
Up arrow selects exercise mode:
Display reads “
[ on
” (“ on]”)
Down arrow clears exercise mode.
Display reads “
[ OFF
” (“ OFF]”)
Enter button executes selection and exits to D01
D17
Restore Defaults
Restores all settings to factory defaults
Display defaults to “
rd. no
”
Up arrow will select restore defaults:
Display reads “
rd.YES
”
Down arrow will deselect restore defaults.
Display will read “
rd. no
”
Enter button will execute selection and exits to D01
Caution: This function will erase scale calibrations,
temperature probe calibrations, changes to target
weights, temperature setpoint, alarm setpoint, and will
reset passwords to defaults.
D18
Power Volts
Displays the current power supply voltage.
Enter Button exits the function and returns to D01
•
Use the Up
and Down
Arrow Buttons to find the desired function.
•
Press the Enter
Button to select the desired function.
•
Basket Size Buttons also function as numbers:
(Left Small=1, Left Medium=2, Left Large=3, Right Small=4, Right Medium=5, Right Large=6)
Service Password to access both the Manager Menu and Diagnostic Menu: 22463
Note: Using the Service Password to access the Manager Function menu will erase the
manager’s password (if set) and restore it to default (no password).