AIR100L 08
Operation
Operation
BEFORE OPERATING YOUR NEW AIR
COMPRESSOR
Please check the following points carefully:
- Check that all nuts and bolts are secure.
- Make sure oil has been properly added to
compressor.
Initial start-up
- Open the air tank drain valve to permit air
to escape preventing air from pressure
buildup air tank.
- Run the air compressor for a minimum of
20 minutes in this “up-load” position to
lubricate the piston and bearing.
- Close air tank drain valve. Your
compressor is ready for use. Depending on
the CFM draw of the tools being operated,
your new air compressor can be used for
operating paint sprayers, air tools, grease
guns, air brushed, caulking guns, abrasive
blasters, tire & plastic toy inflation, spraying
weed killer and insecticides, etc. Proper
adjusting the air pressure regulator is
necessary for all of the these operations.
Refer to the air pressure specifications
provided with the tool you are using.
General overview
To compress air, the piston moves up and
down in the cylinder. On the down stroke air
is drawn in through the valve inlet. The
discharge valve remains closed. On the
upstroke of the piston air is compressed; the
inlet valve closes and air is forced out
through the discharge valve, through the
check valve, and into the air tank. Working
air is not available until the compressor has
raised; the tank pressure above that required
in the air service connection. The air inlet
filter openings must be kept clear off
obstructions, which could reduce air delivery
of the compressor.
Installation and location
Locate the compressor in a clean, dry and well
ventilate area. The compressor should be
located 12 to 18 inches against walls or any
other obstruction which would interfere with
airflow. Place the compressor on a firm, level
surface. Keep all of spare parts which collect
dust or dirt clean. A clean compressor runs
cooler and provides longer service. Do not
place rag, containers or other materials on top
of the compressor.
Connecting to power source
This air compressor is designed to operate on
a properly grounded 230V,50HZ,single phase,
alternating current power source. It is
recommended that a qualified electrician verify
the ACTUAL VPLTAGE at the receptacle into
which unit will be plugged and confirm that the
receptacle is properly fused and grounded.
The use of the proper circuit size can eliminate
nuisance circuit breaker tripped while
operating your air compressor.
Extension cords
For optimum air compressor performance and
extension cord should not be used unless
absolutely necessary. If necessary, care must
be taken to select an extension cord
appropriate for use with specific air
compressor. Select a properly grounded
extension cord which will mate directly with the
power source receptacle and the air
compressor power cord without the use of
adapters. Make certain the extension cord is
properly wired and in good electrical condition.
Extension cords must be #14 gauge or 1mm
2
at the smallest. Do not use an extension cord
over 25ft. in length.